Loading...
HomeMy WebLinkAboutBLD02-112 Waterman & KatzBuildin& 181 Quincy Str=t. Suite 301 PortTowmend. WA98368 _: (360) 379-3208 Fax: (360) 385-7675 . CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE CaD 385-2294 for Inspection Permit Number: BLD02-112 Issued: OS/29/02 Parcel Number: 984 900 502 Job Address: 810 Rose Street Zoning: R-I1 Type: V-N Occupancy: ~ Nature of Work: Remove existinl!: cedar roofinl!: on house: install sheetinl!:o felt and comDosition shineleso and Drovide adeauate ventilation. Owner: Brent Shirlev Contractor: HODe Roofinl!: - HOPERu043N7 (385-5653) GENERAL CONDmONS APPLY - SEE LAST PAGE RE UlRED INSPECTIONS DEMormON All construction debris to be deposited in Jefferson County Landfill or other location in accordance with all local, state and federal laws. APPROVEDfDATE SHEATHING Nailing requires 8d @ 6" o.c. edges & 12" o.c. field or 1 W' staples @ 6" o.c. edges and field. ROOF VENTING Ridge Vents Net free ventilation area shall not be less than I square foot per 150 square feet of the area of the space ventilated, unless 50% of the required vent opening area is provided in the upper portion of the roof and therefore the rate may be reduced to 1 square foot of venting to 300 square feet of area vented. Openings shall be covered with corrosion resistant W' mesh. ROOFING Install all roofing material per manufacturer's specifications and UBC Chapter 15. . CaD 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of2 Pamit fIBl.D02-112 FINAL Smoke detectors required per 1997 UBC (battery powered OK) House Numbers - 5" numbers of contrasting color posted near main entrance of house and visible from street per City Ordinance Final - Building . IGENERALCONDmON~ 1. Contractors workina: on this project are required to have a Labor & Industries contractor's relristration number and a Citv business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. If temporary erosion and sediment control (TESC). measures are required, they shall be installed on-site and inspected prior to he&innina: construction; call 38S-2294. Measures shall include installation of silt fencina: and graveled construction entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabiJized with mukhing, plastic sheetioa:, ete. Solls shall be permanently stabilized with seeding, plantina:s, sodding, ete. once construction is complete. Applicant is respoosible for protection of adjacent properties. 3. All elements of engineering includina: nailina:, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. . 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is reaui~. Public Works aDDroval must be received Drior to schedulinl!: the Buildine Denartment's final insDection. 7. Final Inspections are required prior to occupancy; a Certificate of Occupancy is required for a non- residential project. 8. AU building permits expire if DO proa:ress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at Jeast one inspection per year to keep your building permit active. 9. Revisions require submittal & approval prior to making chana:es in the field. Contact the Bulldina: Department @ 379-3208 prior to makina: chana:es to the approved plans. 10. POST TInS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 boun before you dig for utility line locates 1-800-424-5555 Page 2 of2 .