HomeMy WebLinkAboutBLD02-109 Watennm &: KatzBuiJding 181 QuiDoy....... ..... 301 POItTownaend. WA98368 Phone: (360)379-3201 Fax: (360)31507615 CITY OF PORT TOWNSEND CONS1RUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Can 385-2294 for Inspection Permit Number: BLD02-109 Issued: 06/27/02 Parcel Number: 984 905 702 Job Address: 525 U Street Zoning: R-n Type: V-N Total Occupant Load: 2 (basement) Occupancy: R-3 Nature of Work: Construct new basement foundation - unheated. unfinished snace Owner: Michael Aubin & Elizabeth Albers Contractor: Same as Owner GENERAL CONDmONS APPLY - SEE LAST PAGE PI. !f516~ ({ SEPARATE PERMITS REOUIRED: Electrical- Contact Labor & Industries @ 360-417-2702 RE UIRED INSPECTIONS TEMP EROSION & SDM'T CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site; rights-of-way shall be kept clean of dirt and debris APPROVEDIDATE FOOTINGS Setbacks - existing footprint Footings Forms Reinforcement Interior Footings UFER ~w ~.~ 118/r:>1-Gf €e:mIlt1l<Hif0?/ S/02~ ?1 FOUNDATION - CMU Stem Wall Forms Reinforcement Bond Beam Anchor Bolts & Washers Waterproofing r€&m1A/A/l}{qL -="- ~/;Zo/Ob F-I. /Ojlt;jtY&(f . Can 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of3 Permit # BLD02-109 RE UIRED INSPECTIONS FRAMING: Walls Wall Bracing Treated Wood to Concrete Shield under Posts Positive Connections Fire Blocking Weather Resistive Barrier APPROVEDIDATE INSULATION - unheated basement Floor - ( fill cavity ) FINAL House Numbers - 5" Plumbing MechanicallHeating Insulation Certificate Vapor Barrier Paint Certificate Smoke Detectors Final- Building . GENERAl. CONDlTIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's re2istration number and a C"rtv business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shaD be installed aD-site and inspected prior to beginnin& construction; caD 385-2294. Measures shaD include installation of silt fencing aild graveled construction entrance (see attached details). Adjacent rights-of-way shaD be kept free of dirt debris. Soils exposed during constructioa shaD be temponrily stabilized with mulching, plastic sheeting, ete. Soils sbaD be permanently stabilized with seedina, pIantinp, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. An elements of enp.ring including' nailing, boldowns, sheathina, and alternate braced waD panels (ADWP) require inspection prior to cover. 4. Owner or owner's agent shaD review and oversee correction of any and all deficiencies noted by required inspections. So Re-inspection is required after inspection report corrections are completed. CaD 48 hours before you dig for utility line locates 1-800-424-5555 Page:l of3 . Permit # BLIX.l2-I09 . . 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum oftwentv-four hours notice is required. Public Works aooroval must be received orior to schedulin!! the Buildin!! >>euactment's final insoection. 7. Ymal Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non- residential project. 8. All building permits expire if no pro&ress has been made within six months, or if no inspections are done by the Building Department within one year. CaD for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval urior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. . . CaD 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3 ~ , . It . .