HomeMy WebLinkAboutBLD02-107
W_&KatzBuildWg
181 Quiney Street,. Suite 301
Port Townsend. WA 98368
Phone: (360)379.3208 F8X: (360)385-7675
e
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD02-107R-l Issued: 11/25/02 Parcel Number: 989800066 & -67
Job Address: 884 West Park Avenue
Zoning: PUD
Type: V-N Occupancy: !!
Total Occupant Load: NA Nature orWork: Install Mechanical Svstem (heat numns) and DuctiDl~
Owner: Jefferson Mental Health Services
Contractor: Poulsbo Sheet Metal- POULSSM032CO
GENERAL CONDmONS APPLY - SEE LAST PAGE
RE UIRED INSPECTIONS
MECHANICAL
Exhaust Vent Termination
Heat Pumps & Air Handler
Factory Applied Nameplate
Manufacturer's Operation Instructions Attached
Unit ID'ed for area served
Access and work space for maintenance
Disconnect
Condensate Drain
NREC Temperature Zones
Thermostat Controls
Deadband Control
Night Setback with 7 different day types
Microprocessor controls
Dampers
Duct Insulation & Sealing
APPROVEDIDATE
12(!r~
FINAL - see also original building permit #BLD02-107
Mechanical
WSVIAQ
Certification letter from installer stating compliance with
fresh air requirements
.,
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of2
. .
ParmitifBLD02...107R_}
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's re!!istration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
-
2. Temporary erosion and sediment control (TESC) measures shaD be installed on-site and inspected prior
to beginning construction; caD 385-2294, press 3. Measures shaD include instaDation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A
minimum oftwentv-four hours notice is reauired. Public Works aooroval must be received prior to
schedulin!! the BuUdin!! Denartment's final insoection. =-
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non--
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. CaD for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of2
~
-- ~.... , -
r-
Watermm & KatzBuildin&;
181 Quincy Street,. Sww lOt
POItTownsend,. WA98368
Phone: (360) 379~3208 Fax:: (360) 385-7615
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
.
Permit Number: BLD02-107 Issued: 10/03/02 Parcel Number: 989800066& 989800067
Job Address: 884 West Park
Zoning: M-C Type: V-N Occupancy: !!
Total Occupant Load: 117
Nature of Work: Construct 4676 sa. ft. addition
Owner: Jefferson Mental Health Service Contractor: Little and Little Construction
LITTLLCI57C5
GENERAL CONDITIONS APPLY - SEE LAST PAGE
SEPARATE PERMITS REOUIRED:
Mechanical- Heat Pump Units and Ducting as Deferred Submittal
Lighting - Revision required for Daylight Zones & Controls
Electrical- Contact Labor & Industries@ 360-417-2702
Street & Utility Development Permit - contact Francesca Franklin @ 379-5093
Signage must conform to City regulations - contact Jean Walat @ 360-385-0644
~
REOUIRED INSPECTIONS APPROVED/DA TE
TEMPORARY EROSION & SEDIMENT CONTROL
Temporary erosion and sediment control measures shall be I~V~ (/
installed on-site as needed during construction to contain dirt
and sediment on-site. At:ijacent rights-of-way shall be kept clean
through sweeping of paved surfaces, tire wash, etc.
FOOTINGS /rfwfJ-rf
Setbacks
Concrete Plinth Footings
Forms
Vertical Resteel
Horizontal Ties
Treated Sill
Anchor Bolts
Engineered Holdown Hardware
. .
GROUNDWORK PLUMBING Irj~102-- cf
Pressure Test
Pipe Joints Exposed
Pipe Bedding
Trap Seal Protection
e
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of5
.
Permit 1IBLDo2.) 07
RE UlRED INSPECTIONS
MONOLITHIC SLAB
Forms
Reinforcement
Anchor Bolts
Treated Wood to Concrete
R-IO @ perimeter
Engineered Holdowns
UFER
APPROVEDIDA TE
PLUMBING: Barrier-Free Compliance Required
D-W-V Rough-In
Water Supply
Water Hammer Arrestors
Floor Drains - trap seal protection required
Pipe Insulation - R-3
Hose Bibbs - backflow protection required
Hot Water Heater
Seismic Restraint
PTR Valve Drain to exterior
r1/~v rp
."
MECHANICAL
HV AC - Heat PumplFumace Units & Ducting as deferred
submittal
NREC Temperature Zones
Thermostat Controls
Deadband Control
Setback with 7 different day types
Microprocessor controls with heat indicators
Dampers
Duct Insulation and Sealing
Call 48 hours before you dig for utility line locates
1-8110-424-5555
Page 2 of 5
.-
"
.
.
,
RE UIRED INSPECTIONS
FRAMING
Walls - Engineered Shear Walls
Roof - Engineered truss plan to be on-site at time of
Inspection
Blocking
Roof Drains
Attic Venting - plans show gable end, ridge & eave
Window Safety Glazing
Window U-factor - .40 or better
Doors - .60 or better
Air Seal
Rafter & Truss Positive Connections
Fire Blocking
Draft Stop
Weather Resistive Barrier
INSULATION
Walls-R-19
Roof - R-3 8 attic
Barnes
Vapor Barrier required - 4 mil poly, vapor barrier paint, etc.
R-IO@ slab perimeter
DRYWALL
Walls
Ceiling
LIGHTING - revision relluired to include davliflht zones
and controls
Exterior Lighting per NREC
High- or low-sodium lights recommended; metal halide
discouraged
Permit #BLD02.107
APPROVEDIDA TE
I (l2-o/d J--- f/
J ~/ i/JL
110/" t/7
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 5
RE UIRED INSPECTIONS
PARKING - Barrier Free required
(1) Van Accessible Space - tactile and visual detectable
warnings required where space crosses vehicular way
Accessible path of travel required from bus stop to main
entrance
LANDSCAPING
Contact John McDonagh @ 379-5085 for inspection
FINAL
Property address posted - min. 5" numbers
Public Works Department Sign-Off
Fire Department Sign-Off
Electrical Sign-off (L & I)
ifo{ d~
Barrier Free access
Plumbing - Barrier Free Required
Mechanical
Heating
WSVIAQ
Certification letter from installer stating compliance with
fresh air requirements
Restroom wall and floor covering per UBC 807
Insulation Certificate
Door panic hardware Main exit may have key locking
device with sign at exit: "TInS DOOR TO REMAIN
UNLOCKED DURING BUSINESS HOURS"
with 1" high letters on contrasting background
Exit Signage
Exit lllumination
Occupant Load Posted in A Occupancy
Final- Building
Permit #BLD02:107
APPROVEDIDA TE
.
~l~...h dJ4 6~
'fef; cr/ 4-/ D?
~
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of5
...,
4.
~-
.
3.
4.
5.
6.
.
7.
8.
It
Permit #BI..D02.107
GENERAL CONDmONS
1. Contractors working on this project are required to have a Labor & Industries contractor's rel!istration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; caD 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.,
Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
Re-inspection is required after inspection report corrections are completed.
The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum oftwentv-four hours notice is reauired. Public Works aDu.oval must be received urior to
schedulinl! the Buildinl! Deuartment's final insoection.
Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non-
residential project.
All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 5 of5
~
.
.
-
/