HomeMy WebLinkAboutBLD02-085
Waterman & Katz Building
181 Quincy Street, Suite 301
Port Townsend. WA 98368
Phone: (360) 379.3208 Fax: (360) 379-6923
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD02-085R-2 Issued: 01106/03
Parcel Number: 948 305 203
Zoning: R-I1
Type: V-N Occupancy: R-3/U-l
Job Address: 1011 Holcomb Street
Total Occupant Load: NfC Nature of Work: Revision #2: add nicture window to dininl! area.
Owners: Don D' Alessandro & Nancv Bil!elow
Contractor: Same as owner
GENERAL CONDITIONS APPLY - SEE LAST PAGE
SEPARATE PERMITS REOUIRED:
Electrical - Contact Labor & Industries @ 360-417-2702
NOTE: for other inspections, see original permit BLD02-085
RE UIRED INSPECTIONS
FRAMING
N'indow U-factor - .40 or better
NFRC sticker shall be on windows @ time of inspection
Revised Holdown Locations
Engineered Sheerwalls
Positive Connections - A-34 and H-l
APPROVEDIDA TE
IfO~
FINAL
Building - See also original permit #BLD02-085
for house construction
4t
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of2
Permit # Bl.D02-085R.2
fiENERAI, CONDmONS
1. Contractors working on this project are required to have a Labor & Industries contractor's rel!istration .
number and a Citv business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twentv-four hours notice is required. Public Works approval must be received prior to
schedulinl! the Buildinl! Department's final insDection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non- .
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval Drior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of2
41
Watennan&.KatzBuiIding
181 QWn<y S..." Swtc 301
PortT""",""",- WA98368
Ph"",: (360) 379-3208 Fax: (360) 3~
.
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD02-085R-l Issued: 10f02f02
Parcel Number: 948 305 203
Job Address: 1011 Holcomb Street
Zoning: R-I1
Type: V-N Occupancy: R-3/U-l
Total Occupant Load: NIC Nature of Work: Revision #1: add dormer and 2 skvlil!hts to bonus room.
add back Dorch over rear deck. remove rear steps and railinl! on rear deck to !!fade.
Owners: Don D' Alessandro & Nancv Bil!elow
Contractor: Same as owner
GENERAL CONDITIONS APPLY-SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical- Contact Labor & Industries @ 360-417-2702
RE UIRED INSPECTIONS
PORCH FOOTINGS
Setbacks
'ost BaseIPositive Connection
'Treated Wood to Concrete
Rafters
Blocking
Seismic Ties
APPROVEDIDATE
FRAMING
NOTE: Engineered BCI roof plan, including reference
to addition of dormer, to be on-site @ time of inspection
Walls
Engineered shear walls
Window U-factor - .39 or better - NFRC sticker shall be on windows
@ time of inspection
Skylights
Fresh Air Intake (Window Ports)
Ceiling
Posts BearDS & Headers
Roof - engineered truss plan on-site at time of inspection
RafterlTruss Positive Connection
Fire Blocking
Weather Resistive Barrier
/7/03 tf!
'=
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 012
Permit *BL002..osm.J
RE UIRED INSPECTIONS
FINAL
Building - See also original permit #BLD02-08S
for house constnlction
APPROVEDIDATE
GEN1i;RAI, CONDTTlONS
1. Contractors workingoD this project are required to have a Labor & Industries contractor's rel!istratioD
Dumber and a Citv business license. Failure to provide proof of this documentatioD prior to work may
result in job shut down while this is accomplished. .
2. Temporary erosioD and sediment cODtrol (TESC) measures shall be installed on-site and inspected prior
to be&inuing COnstructiOD; call 385-2294. Measures shall include inStallatiOD of silt fencing and graveled
COnstructiOD entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt debris. Soils
exposed during constructioD shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. ODce COnstructiOD is complete.
Applicant is responsible for protectioD of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and. alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspectioDs.
5. Re-inspection is required after inspectioD report corrections are completed.
.
6. The Building Department is unable to pass final inspectioD OD your project uutiI Public Works
requirements have been completed and inspected. For Public Works inspectioD call 385-2294. A
minimum of twentv-four hours notice is reouired. Public Works approval must be received prior to
scheduliDl! the Buildinl! Department's final insDection.
7. Final InspectioDs are required prior to occupancy; A Certificate of Occupancy is required for a DOn-
residential project.
8. All building permits expire if DO progress has been made within six mODths, or if no inspections are dODe
by the Building Department within ODe year. Call for at least ODe inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plaos.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
.
CaD 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of2
Waterman. & Kdz BuikliDa
181 Quincy Stra:t,. Suite 301
PortTOWDSeDd,. WA98368
!'boo." (36O)37!>-32ll8 F.,q360)3lIS-767S
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
.
Permit Number: BLD02-085
Issued: 06110/02
Pared Number: 948 305 202/203
Job Address: 1011 Holcomb Street
ZoninE: R-I1
Type: V-N Occupancy: R-3/U-l
Total Occupant Load: 5/2
Nature of Work: Construct sinl!le-familv residence with attached l!aral!e
Owner: Don D' Alessandro & Nancv Bil!elow
Contractor: Same as Owner
GENERAL CONDITIONS APPLY-SEE LAST PAGE
SEPARATE PERMITS REOUlRED:
Electrical- Contact Labor & Industries @ 360-417-2702
"*ALL ELEMENTS OF ENGINEERING REOUIRE INSPECTION PRIOR TO COVER...
.
REOUIRED INSPECTIONS APPROVEDIDATE
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS 111 dz-flJ
Setbacks
Footings
Forms
PorchfDeck Piers
Reinforcement
Interior Footings
UFER
.
Can 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
~
_*JlUlll2.<llIS
RE UIRED INSPECTIONS
FOUNDATION
Stem Wall
Fonns
Reinforcement
Anchor Bolts
Beam Pockets
Foundation Vents (9 required)
Crawl Access
Beam Pockets
Engineered Hold downs
Waterproofing
APPROVEDIDATE
r{b/&v~
FLOOR FRAMING - BCljloor framing plan to
be on-site III time of inspection
Joists
Girder
Blocking
Shield under Posts
Positive Connections
Girder-to-concrete
Beam Pockets
Treated Wood to Concrete
Anchor Bolts wI 2" x 2" x 3/16" washers
(7/03 ~
PLUMBING:
Rough-In (D-V-T & Clean outs)
Water Supply
Gas Supply
Water Hammer Arrester@c1othes & dishwashers
Hose Bibs (bacldlow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
R-I0 under if e1ectric and on slab
18" A F. F. iflocated in garage
Seismic Restraint - strap tank @ 1/3 points
Pressure relief valve drain to exterior
Y1fo3~ .
L-pG I MJt ~ P. FIi 11'102-
Propane F~
o e an - bathroom
Source Specific Fans
Environmental Air Exhaust ducting (wI backdraft dampers),
insulation (R-4) and terminus (located 3' from opening)
;/1(03 rf
~
CaD 48 houn before you dig for utility line locates
1-800-424-5555
Pap2of4
j
Permit II BLD02-08S
RE UIRED INSPECTIONS
FRAMING
Walls
Engineered Shear Walls
Ceilings
Posts, Beams & Headers
Roof - engineered truss plan on-site at time of inspection
Truss Positive Connection
Roof Venting - eave and continuous ridge vent
Windows - escape
Windows - safety glazing
Windows U factoc - .39 or better
NFRC window sticker must be on windows &
doors at inspection time
Fresh Air Intake (Window Ports)
Doors U-Factor - .20 oc better
AirSea1
Fire Blocking
Weather Resistive Barriec
APPROVEDIDATE
t rit-9j oz-- tP
/;zCJ-?
y
INSULATION
Walls (R-llincluding house/garage wall )
Ceiling (R-38 )
Floocs ( R-W
Vapoc Barriec: paint@ walls; backed batts @ ceiling
Bafiles
6 mil black poly
DRY WALL NAILING
Walls
Ceiling
Enclosed Space under Stairs (if applicable)
GarageIHouse Occupancy Separation
P a ~.c{ ~/cJ /03 p-e--
C.L ~ GO rrfu..A--- .
FINAL
Public Works Sign-Off
LPG
House Numbers - 5" minimum
Plumbing
MechanicallHeating
Vapor Barrier Paint Certificate
Insulation Certificate
Smoke Detectors
Final- Building
/0
cL/_
J
/
/"
~
.')
i,.../
.,
can 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of ..
~
_#BLIlllU85
I
,
GE~AT, CONDmONS
-
1. Contractors working on this project are required to have a Labor & Industries contractor's reooration
nomber and a Citv business license. Failure to provide proof of this doeomentation prior to work ml)'
result in job shot dowD wbilethis is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed OD-Site and inspected prior
to beginning construction; call 385-2294. Measores shaD include installation of silt fencing and vaveled
COnstructiOD entrance (see attached detaib). Adjacent rights-of-way shaD be kept free of dirt debris. Soils
exposed during C:OnstructiOD shaD be temporarily stabilized with mulching, plastic -lIeeting, etc. Soils
shall be permanently stabilized with seeding, plantinp, sodding, etc. once c:onstruction is complete.
Applicant is responsible for protectioD of adjaceDt properties.
3. All elements of engineering incloding nailing, holdo1l'D" sheathing, and alternate braced wall panels
(ABWP) require inspectioD prior to cover.
4. Owner or o1l'Der's agent shall review and oversee correction of any and all deficiencies Doted by required
inspections. .
S. Re-inspectioD is required after inspection report c:orrections are completed.
6. The Building Department is unable to pass final inspection on yoor project until Public Works
requirements have been c:ompleted and inspected. For Public Works inspection call 385-2294. A
minimum of twentv-four hoors notice is reouired. Public Works aDDroval must be received Drior to
scbedulinll the Buildinl! Denartment's finAl insnectiOD.
7. Final Inspections are required prior to occupancy; A Certificate of Oceupancy is required for a non-
residential project.
.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval Drior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
CaD 48 boun before you dig for utllity line locates
1-800-424-5555
Page 4 of 4
4t