Loading...
HomeMy WebLinkAboutBLD02-076~, CITY OF PORT TOWNSEND Wrte®m & KmzBuild'mg tet nor sweat s~ 3ot Pal Towmmd, WA 98368 Plas<: (360) 3'793208 Fu: (360) 385.7676 CONSTRUCTION PERNIIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca0 385-2294 for Ins lion Permit Number: I3LDU2-076 Issued: 06/07/02 Parcel Number: 947 600109 Job Address: 4153 Gise Street Zoning: R-I Type: V=N Occupancy: R-3/U-1 Total Occupant Load: 612 Nature of Work: Construct sinele-fsmiW residence with attached ¢ara2e Owner: Johnathan Rvweck Contractor. Vern Garrison Construction VEItNOGC062Q8 GENERAL CONDITIONS APPLY -SEE LAST PAGE -r L , ~ , ~ SS v ~'D 1~(D// 3/OL SEPARATE PERMITS REOUIItED: ~"P7i~~ Z~/3/DL `^I Electrical -Contact Labor & Industries (a3 360-417-2702 ***ALL ELEMENTS OFENGINEERING REQUIRE INSPECTIONPRIOR TO COVER*** -~ RF.OTITRED TNSPE("TTONS APPROVED/DATE TEMP EROSION & SED]MENT CONTROL See General Condition No. 2 Silt Fence as needed Drive OffMat to restrict sediment from leaving the site FOOTINGS , /,/ ~~ 'l C Setbacks ~ Footings Forms Porch/Deck Piers Reinforcement Footings IJFE . ~ , Call 48 hours before you dig for ut0ity line locates ' 1-800.424-5555 Page 1 of 4 re~maRSioozma REQUIRED INSPECTIONS APPROVF.D/nATF. FOUNDATION Stem Wall Forms /~~1 /~ ~~ 2~ ® ~7 ,1 1~ / Reinforcement ~1 ~ ~%f ~ Anchor Bolts - ~ Beam Pockets Foundation Vents (9) Crawl Access Engineered Hold downs Waterproofing FLOOR FRAMING - BCI floor fro»ung plan to be on-site at tine of inspection ~/j~ / Joists ~ / "~~' l Girder 1 L Blocking Shield under Posts Positive Connections Girder-to-concrete Beam Pockets Treated Wood to Concrete Anchor Bolts w/ 2" x 2" x 3/16" washers PLUMBING: Rough-In (D-V-T & Clean outs) ~ ~ / ~~~ /~ /~ ~ ~~' Water Supply Zl Gas Supply '' Water Hammer Arrester (tD clothes & dishwashers Hose Bibs (backfiow protection required) Pipe Insulation (R-3) Pressure Reduction Valve if> 80 psi Water Heater R-10 under if electric Seismic Restraint -strap tank Q 1/3 points Pressure relief valve drain to exterior, terminate 6" - 24" above ground MECHANICAL - mamrfactrver's installation 11 be on-site of time of inspection Propane Boiler _ o e bathroom Source Specific Fans Environmentai Arr Exhaust dulling (w/ backdraft dampers), ^/ n /J insulation (R-4) and terminus (located 3' from opening) ~~ l~ J Q ~ / ~// l ~ Ca1148 hours before you dig for utility line bcates 1-800.424-5555 Page Z of 4 `J Pamir # BI.D03-076 REOUiRED INSPECTIONS APPROVED/DATE FRAMING Walls ;~~ ~~~~ Engineered Shear Walls Ceilings Posts, Beams & Headers Roof- engineered truss plan on-site at time of inspection Truss Positive Connection Roof Venting - save and continuous ridge vents Windows -escape windows -safety glazing Windows Ufactor - .65 or better NFRC window sticker must be on windows & doors at inspection time Fresh Air Intake Window Ports) Doors U-Factor - .40 or better Skylights - .40 or better Air Seal Fire Blocking Weather Resistive Barrier INSULATION Slab (R=10 with thermal break ~a garage/house ) Walls (R-19 including house/garage wall) ~~~` a,~ b ~~~, Ge~~~ S ~ 0) a ( b ~.~-1 ti„b (y ~ • 13• loor R-14 ( ~ Vapor Barrier: paint Baffles 6 mil black poly DRY WALL NAILING Walls Ceiling ~~~ 1/ ~ ( Enclosed Space under Stairs l GarageiHouse Occupancy Separation Interior Braced Wall Panels FINAL Public Works Sign-Off LPG ~G ~ //~ /~ ~ ~~ ~ d/ House Numbers - 5" minimum Plumbing r- ~ ~ ~~ ~ MechanicaVHeating ~ ~ ~ O ~ Vapor Barrier Paint Certificate Insulation Certifcate Smoke Detectors Final - Buildin Call 48 hours before you dig for utility live locates 1-800-A24-5555 Page 3 of 4 rya x erom.o~e 1. Contractors working on this project are required to have a Labor Bt Industries contraMor's reeistration n m r sad a City business Gcensa Fa0nre to provide proof of this docnmeatatioe prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment rnntrol (TESC) measures shah be instatkd oo-site and inspected prior to begiming construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (ace attached details). Adjacent rights-of-way shall be kept frce of dirt debris. Soils ezposed dnriog rnnstruction shat! be temporarily stabilzed with mulching, plastic sheeting, eta So~7s shall be permanently stabilized with seeding, plantings, sodding, eta once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require insPcetion prior to cover. 4. Owner or owner's agent shall review anal oversce correction of any and all deficienciav noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed 6. The Building Departmwt is unable to pass final inspection on your project natil Public Works requirements have bees completed and inspected For Public Works inspection call 385-2294. A minimum ottweMv-four hours notice is reamred Public Works aonroval mnst be recaved prior to 7, Final Inspections are required prior to occupancy; A Certificate of Occnpancy is required for a noo- residentid proje~k. 8. All building permits expire if no progress has been made within sin months, or if no inspections are done by the Building Department within one year. Call for at kart one inspection per year to keep your building permit actives 9. Revisions require submittfd and approval prior to makinE changes in the field Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. CaQ 48 boars before you dig for utility line locates 1-800-424-5555 Pa~4M4