HomeMy WebLinkAboutBLD02-071W~imo~e Q Kris BuYdin6
181 Qdxy Sheet' SuBe 901
Pat Tamaod, WA %968
Phone: 360J793086 T>s360385-7b73
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
TffiS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: $LD~2-~71 Issued: OS/Ol/02 Parcel Number: 001-104-020
dob Address: 400 Wilson Street Zoning: RR=II Type: VV=N Occupancy: RR=3
Total Occupant Load: ~ Nature of Work: Remodel Sinele-family Dwelling
Owner: David and Ann Wine¢ar Contractor: Discovery Bav Construction
DISCOBC090B9 (301-4191)
GENERAL CONDITIONS APPLY: See Last Pace
SEPARATE PERMTTS REOUIItED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
RF,OUiRF.D iNSPECTION5
APPROVED/DATE
DEMOLITION
Materials from demolition sha71 be taken to the Jefferson
County Landfill or other approved ofj~` site location
meeting all state and local codes
FOOTINGS ,~A~~~~
Setbacks - no change /~! ~~ ~ ,
C~~
/
Footings /
/
Forms
Reinforcement
Interior Footings
Porch Piers
FOUNDATION
Stem Wall
Forms
Reinforcement
Engineered Holdowns
Anchor Bolts & Washers
Vents - 4 required
Crawl Access
Wate roofin
CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 4
REQUIRED INSPECTIONS
Building Permit NM-071
APPRnVF,ln/IIATF
FLOOR FRAMING
Joists -engineered BCI plan shall be on-site at time of
inspection ~,
Blocking
Pos' 've Connections /
~i ~/ "Z--
Engineered Floor Straps ~
Treate ood to Concrete ~~
Anchor Bolts & Washers ~
PLUMBING
Rough-In (D-V-T & Clean outs)
?/~. 'S/~ Z ~D
Water Supply ~
J
Pipe Insulation (R-3) I
Pressure Reduction Valve if > 80 psi
MECHANICAL
Whole House Fan in Bath 7/2 ~6 Z
Environmental Air Exhaust ducting (with backdraft dampers),
insu]ation (R-4) and termination (3' from openings into
building)
FRAMING ^ -
Engineered Shear Walls
Roof- engineered truss plan shall be on-site at time of
Inspection
Truss/Rafter positive Connections
Attic Venting -gable end and eave
Windows -escape
Windows- safety glazing
Window/SGD Door U-factor - refer to calculations
NFRC sticker must be on windows and doors
Air Seal
Fresh Air -window or wall ports required
Fireblocking
Weather Resistive Barrier
INSULATION -per calculations
Walls (R-21)
Z ~~D~
Floor (R-38) !
Roof (R-49/R-38)
Baffles
Vapor Barrier: paint
6 mil black poly in crawl space
."
Call 48 hours before you dig for utility line locates
I-800-424-5555
Page 2 of 4
Building Permit #02-071
RF.CITITRFT) TNCPF.C'TTnN~
APPROVED/DATE
DRYWALL NAILING
Walls
i
~ ~~~~
Ceilings
Enclosed Usable Space under Stairs
FINAL
Landings
House Numbers - 5" numbers
Plumbing /
Mechanical/Heating ! ~~
Insulation Certificate
Vapor Barrier Paint Certificate
Smoke Detectors throughout
Finat -building
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
contractor's registration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and
inspected prior to beginning construction; ca11385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public
Works requirements have been completed and inspected. For Public Works inspection call
385-2294. A minimum of twenty-four hours notice is reauired. Public Works aaaroval
must be received arior to scheduling the Building Department's final inspection.
• Call 48 hours before you dig Tor utility line locates
1-500-424-5555
Page 3 of 4
Building Permit #02-071
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All building permits expire if no progress has been made within sia months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800.424-5555