HomeMy WebLinkAboutBLD02-070
.
.
.
,
w_ & Kalz Building
181 Quincy Street Suite 301
Port Townsend. W A 98368
Pbonc (360) 379.3208 Fax (360) 383.7673
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
can 385-2294 for Inspection
Permit Number: BLD02-070
Issued: 05108/02 Parcel Number: 974-101-501
Job Address:
1705 Monroe Street
Zoning: R-1I
Type: V-N Occupancy: R-3
Total Occupant Load: .L
Nature of Work: Remodell!aral!e to ADU
Owner:
Jennifer Bloml!ren
Contractor: Off tbe Grid Solutions - OFFGRS*991L 7
Michael Story (379-0293)
GENERAL CONDmONS APPLY - SEE LAST PAGE
SEPARATE PERMITS REOUlRED:
Electrical- Contact Labor & Industries @ 360-417-2702
RE UIRED INSPECTIONS
DEMOLmON
Construction debris shall be deposited in the
Jefferson County Landfill or other approved areas
off-site
APPROVED/DATE
MONOUTHIC SLAB - existing
R-7.5 in 2 x sleepers
PLUMBING:
Rough-In (D-V-T & Clean Outs)
Water Supply
Gas Supply
Hose Bibs (backflow protection. req'd.)
Pipe Insulation - R-3
Pressure Reduction Valve if> 80 psi
Water Heater
Seismic Restraint - 2 places
Pressure relief valve drain to exterior
~I /; /J'l-
7/3/ /(f)- (]J
Call 48 bours before you dig for utility line locates
1-800-424-5555
-
RE UIRED INSPECTIONS
ECHANI
LP Gas Stove
Manufacturer's
on- ction
Whole House Ventilation: @ bath
Kitchen Fan
Environmental Air Exhaust ducting (with
backdraft dampers), insulation (R-4) and
terminus (located 3' from opening)
FRAMING:
Walls
Roof
Attic Venting - gable end & eave
Ceilings
Posts, beams & headers
Windows - egress
Windows - safety glazing
Windows U factor - .33 or better
NFRC window sticker must be on
windows & doors at inspection time
Air Seal
Fresh Air: Wall ports
Doors U factor -.37 or better
Rafter Positive Connection "
Fireblocking
Weather Resistive Barrier
INSULA nON
Slab (R-7.5)
Wall (R-I3/R-26)
Ceiling (R-38/3 y," thermax )
Baffles
Vapor Barrier: paint
DRY WALL NAll.ING
Walls
Ceiling
Building Permit #02-070
",
APPROVED/DATE
'7/40 'U ~
1/51(01/ ~
vJcJ2v ~ UaJ); 11r;1()~
0it/ot, Cf
4t
Can 48 hours before you dig for utility line locates
1-800-424-5555
-
-..
.
.
.
~
Building Permit #02-070
REOUIRED INSPECTIONS
APPROVEDIDA TE
FINAL
LPG
House Number - check 5" numbers
Plumbing
Mechanical
Insulation Certificate
v. B. Paint Certificate
Smoke Detectors
Final - Building
L(wfrn--rJ(
,
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
rel!istration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginuing construction; call 385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of way shall be kept free of dirt
and debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic
sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adj acent properties.
3. All elements of engineering including nailing, hold owns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294; a
minimum oftwenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7, Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep
your building permit active.
9. Revisions require review and approval Drior to making changes in the field. Contact the Building
Department at 379-5086 Drior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
-.-'
~..- -_.~ .~
,
-,
.
.
.,