HomeMy WebLinkAboutBLD02-041Waterman & ICah BWiding 181 Quiory Street, Suite 301 Port Towoxnd, WA 98368 Phoce:360J79.5086 Fu36W8S7675 ~~ CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD TIIIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLD02-041R-1 Issued: 01/06/04 Parcel Number: 001-021-003 Job Address: 1531 Monroe Street Zoning: RR=II Type: VV=N Occupancy: R-3/U-1 Total Occupant Load: NC Nature of Work: Revision: change carace to heated shoo/studio; delete stairs to loft (less than 200 square feet, okav to use ladder); engneered holdown chances Owner: Richard & Marv Tietien Contractor: Same as Owner GENERAL CONDITIONS APPLY: See Last Pace SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 REQUIRED INSPECTIONS APPROVF,D/DATF, See also original Inspection Record - -- - FOUNDATION Engineered holdowns approved: PHD6 okay to substitute for HTT22 @ north and west corners of basement; HTT16 okay for HTT22 @ south corner FRAMING Delete stairs to loft; use ladder for < 200 sq. ft. Door U-factors:.35, .39; .14 per calculations Window U-factor:.34 or better INSULATION Gazage slab - NA per calculations Garage Walls - (R-13 per calculations) Garage Roof (R-30) DRYWALL NAILING ` Delete drywall under stairs (stairs removed) Delete gazage/house occupancy separation CALL 48 hours before you dig for Utility line locates 1-800-424-5555 Page 1 of 2 Buildmg Pemtit #02-041R•1 See also originad inspection record GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shot down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11 3 8 5-2 2 94. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarLy stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required Public Works approval must be received prior to scheduling the Building Department's final inspection 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility lice locates 1-800.424-5555 Page 2 of 2 ~J w,~.~ ~ x.~ s~oaw~ ~e~ Qoi~y sue, swk 3oi Pat Tows~md, WA 9K166 pyaea 360379-3086 Fix 360JB5-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD TffiS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLD02-041 Issued: 04/05/02 Parcel Number: 001-0212-003 Job Address: 1531 Monroe Street Zoning: R_II Type: VV=N Occupancy: R-3/[T-1 Total Occupant Load: 8/3 Nature of Work: Remodel Single-family Dwelling, aaraee & caruort Owner: Richard & Marv Tietien Contractor: Same as Owner GENERAL CONDTI'IONS APPLY: See Last Page SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 REt7iJIRED INSPECTIONS APPROVED/DATE TEMP EROSION & SEDIMENT CONTROL See General Condition #2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS Setbacks /© Z Footings -engineered footing @ retaining wall Forms Reinforcement Interior Footings Chimney Footing Porch Deck Piers LIFER CALL 48 hours before you dig for Utility line locates 1-800-424-5555 Page 1 of 4 4 ._\ Building Permit #OZ-04l ~ C REQUIRED INSPECTIONS APPROVED/DATE FOUNDATION Stem Wall -engineered wall @ retaining wall Forms ,R.(~~"~ ~~~ ~ Reinforcement nn~n ~'f'U~~ ~f~,(~~ Anchor Bolts & Washers Waterproofing Engineered Holdowns SLAB Thickened Footings FLOOR FRAMING . NOTE: En ineered TJI flo r l it d g o p an on s e an available to the Inspector at inspection time 1 l^,~ Joists / ~ / lJ Blocking ((( Positive Connection - engineered holdowns Treated Wood to Concrete Anchor Bolts & Washers PLUMBING R h I D V T & Cl n , / ' b IAl V ~ ~~ 1o129V7~w'D~ +C~ oug - n ( - - ean outs) Water Supply . 11 ~ j~l~ /~ II ' Trap Seal Protection / (~ Water Hammer Arrestors ' Hose Bibs - backflow protection required Pipe Insulation (R-3) Pressure Reduction Valve if> 80 psi Water Heater 18" A. F. F. R-10 under if electric Seismic Restraint - 2 places Pressure Relief Valve drain to exterior, terminate 6" -24" above ground MECHANICAL ood Stov ouse Fan @ Utility Room (100 cfrn) Source Specific Exhaust Fans @ bathrooms (SOcfm), kitchen (100 cfm) Environmental Air Exhaust ducting (with backdraft / /~/ Z damper), ® l insulation (R-4), and termination (3' from openings) Call 48 hours before yon dig for utility tine locates 1-800-424-5555 Page 2 of 4 s • REOITIRF.D i1~:SPF.C'TIONS Building PermR #02-041 APPROVED/DATE F lYI Wal s engineered she r walls l~~OlaZ One our Separation etween mare ouse Roo -engineered raf ers above garage / /l S~~ L Rafter/ ss positive onnection Rafter ies Attic venting -ridge & soffit `C/ MSTCGt., c~ b~t,~-~ v-~ off- ~~i~r~ Engineered beams and headers '~ ._.,t-_. Skylights U-factor - .58 or better ~ ~ Windows-escape ~~ ~~` ~~~~ ~~~ 1 t~ ~(-~ ~-{y ~ Windows -safety glazing ',! Window U-factor - .40 or better NFRC sucker must be on windows, skylights and doors at time of inspection Air Seat ? ',-~~~ 4r - Fireblocking ~ ~~ ~~ 3 Weather Resistive Barrier --- INSUT ATT[l~L oor (R-I8 required at slab < 24" below grade) ~ ----------- '~ L f ~ i , ZL,~C, y c~~q Is -19 including garage/house common wall Ceiling (R- rus o Ceiling (30) vaulted ceilings Baffles Vapor Barrier -faced batts DRYWALL NAILING ADU/Main house one-hour separation Walls Ceiling Enclosed usable space under stairs Garage/House Occupancy Separation Interior Braced Wall Panels -per engineering FINAL Public Works Sign-off Wood Stove House Numbers - 5" numbers Plumbing Mechanicat/Heating Carport/Decks Insulation Certificate Smoke Detectors Final -building _ Call 48 hours before you dig for utility line locates T-800-424-5555 Page 3 of 4 ._ Bolding Permit !102-041 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. Alt elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass Tnal inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works approval must 6e received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required Tor anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at (east one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 374-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4 I~TSI~I:C'1'I()\T li.l:l~()li~'1' ~~ NAME ~ Permit No. ~O~- ~~~ d ~ ~~ ~ ~, 9~~ ~.~ , ~~~ ~ _ ~- ~ ~~~ ~~ ~x~ ~ ~~ -~ ~'- ~~~~ `~ V ~ ~- Cam- ~'~: ~ ~~ ~~~' ~~ ~ r ~~ ~ ~ ~~~ ~~~ ~~ ~ ~ 00 NOT REMOVE THIS TAG Date ~ ~ ~t sy CITY OF PORT TOWNSEND, BUILDING & COMMUNITY DEVELOPMENT WATERMAN & KATZ BUILDING, 181 QUINCY ST., SUITE 301, PORT TOWNSEND, WA 98368 (360) 379-3208 YOU ARE HEREBY NOTIFIED THAT NO MORE WORK SHALL BE COVERED UPON THESE PREMISES UNTIL THE ABOVE VIOLATIONS ARE CORRECTED. WHEN CORRECTIONS HAVE BEEN MADE, CALL FOR REINSPECTION AT 365-2294. YOU MAY APPEAL DECISIONS OF THE BUILDING OFFICIAL TO THE BOARD OF APPEALS WITHIN 15 DAYS OF INSPECTION DATE. FOR FURTHER INFORMATION CONTACT BCD AT (360) 379-3208 V O ~ \~ Z ~~\ .~ O Q. ~~ ~ ~ ~~ ~./ ~~ ~~ V ~ +.~ ~' ~ ~ ~+ .~.. ~ Q ~ Z r ~1 M~^1 , +~ A m 1~ ev Fa- N F- W O W F- Z O O 0 w U ~ W O ~ M ~ ~ W O C7 Q Z ~ Z O O U w ~ O z Z ~ w O W ~ > ~ ~ m °~' Y d~ aN o 0 = CO r W 0 ~ M Z ao ~ !- O W W zZ t-cNp ~ ~ ~O 3n Z Z O ~a w~ ~ cn a ,.- ~ ~ aw ¢Q ~O w°C OWv OC °~ O ~~ O¢ C~ ~ OU mZ Q ~ ~ wQ O H J~r^^ W¢ O~ W VJ > W ¢ ¢ D ~ OoWO U~ W U m> OZ Z Z ¢= Zo[ Q ~Z ~_ O ~ O ~ ~~ m~ ~'~ 3~ _~ O~ w¢ t-O a. ? o ° o p~ ~w z }~ z~ O U~ F o Y w w atJ ~ a Z O a Q z ~ w ~ w ~ ~ 0 _ > w 0 r