Permit Number: BLDO2-O4O Issued: 03/20/02 Parcel Number: 930.300-202
Job Address: 306 V Street Zoning: RR=II Type: VV=N Occupancy: R-3/U-1
Total Occupant Load: 2 Nature of Work: Construct detached ADU accessory to 304 V Street
Owner: Lee & Jean Sarinaaate Contractor. Millennium One Homes. Inc
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMTTS REOUIItED:
Electrical -Contact Labor & Industries @ 360-417-2702
a
RE UII2ED INSPECTION5
APPROVED/DATE
TEMP EROSION & SEDIMENT CONTROL
Silt Fence as needed
'Drive Off Mat to restrict sediment from leaving
the site
GROUNDWORK PLUMBING ~~ ~~~ ~~~
Pressure Test /~ L /j/J
7C ~ CJ/
C
Pipe Joints Exposed
Pipe Bedding
Trap Seal Protection (~j7/~
FOOTINGS
Setbacks ~~~OZ (f/
`
Footings ttt
Forms
rcement
~~~
SLAB
R-10 to perimeter
Treated Wood to concrete
Reinforcement: 18" o.c. each way
Anchor Bolts
a.aw +o awwa ucauac,rou ua~ ava uauuJ uuc
1-800.424-5555
Page 1 of 4
REOUIItED INSPECTIONS APPROVED/DATE
FOUNDATION
Stem Wall
~~$~ j~
Forms U j,
Reinforcement
Anchor Bolts w/ 2" x 2" x 3/16" washers
Engineered Holdowns per attached engineering
FLOOR FRAMING
Joists (storage) ~~/~ n /J
~ (
//
Blocking `~(
Positive Connection
PLUMBING:
Rough-In (D-V-T & Clean outs) ~ /Z//D
/ ~J
Water Supply
Water Hammer Arrestor at clothes and dishwasher
Gas Supply ,
, y~j ~2~, ~~3~ zi
~) , /
Pipe Insulation (minimum R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
Seismic Restraint - 2 places
Pressure relief valve drain to exterior, t to
6" - 24° above ground ~
PG Stove -manufacturer's ins lation instructions shall be
on-.site at time of inspecti
- a oom/Laundry
Source Specific Fan -Kitchen
Environmental Av Exhaust ducking (w/ backdraft
dampers), insulation (R-4) and terminus (located 3'from
~~//~
opening) l
CaII 48 boors before you dig for ut0ity liue locates
1-800-424-SSSS
Pam 2 of 4
1
RF,niTIRF.D iNSPF,CTiONS APPROVED/DATE
Pamil k02-000
FRAMING
Walls -Engineered shear walls & holdowns highlighted on
~~ ~~~
plans
Ceilings
Roof
Rafter Positive Connection
Attic Venting - @ ridge & eave
Windows -escape
Window safety glazing
Windows Ufactor - .65 or better
NFRC window sticker must be on windows and doors
at inspection time
Air Seal jj
5~?~ f~
Fire Blocking '/
Weather Resistive Barrier
INSULATION
Floor 51ab - 2 foot perimeter
Walls (R-19 ~
~~~ ~ ~ ~~
Ceiling (R=30 )
Baffies
Vapor Barrier: Face stapled backed Batts
DRY WALL NAILING
Walls
~~~~~ ~>~~
Ceiling
Storage/House Occupancy Separation '
FINAL
LPG
House Numbers - 5"
Plumbing
Mechanica]/Heating
Insulation Certificate
Smoke Detectors
Final -Building
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
GENERAL CONDITIONS
1. Contractors working on this project are required to Gave a Labor & Industries contractor's re¢istration
num r and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior.
to beginning constriction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. So~7s
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, Plantings, sodding, etc.. once construction is complete.
App6ca~ is responsible for protection of adjac~t properties.
3. All elemenb of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report correctiois are completed.
6. The Building Department is unable: to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-
residential project.
8. All building permits ezpire if no progress bas been made within siz months, or if no inspections are done
by the Bui1dmg Department within one year. Call for at least one inspection per year to keep your
bufiding permit active.
9. Revisions require submittal and approval prior to mskiig changes in the field. Contact the Building
Department (379-3208) prior to msldng changes to the approved plans.
10. POST TffiS PERMiT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for uU7ity line locates
I-800-424-5555
Page 4 of 4