CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO2-O2O Issued: 2/15/02 Parcel Number: 974700101
Job Address: 2108 Sims Wav Zoning: CII Type: VV=N Occupancy: B
Tots/ Occupant Load: 47 Nature of Work: TI: add sinks. ADA restroom. comrters. etc.
Owner: McPherson Associates dba: Domino's Pizza Contractor: Great Northwest Builders
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMTTS REOUIIiED:
Electrical -Contact Labor & Industries @ 360-417-2702
Plumbin¢Permlt-Required for grease tray
Sign Permit
RE UIRED INSPECTIONS
APPROVED/DATE
PLUMBING -Barrier Free design required
Contractor to verb that existing sewer is sized to
accommodate additional fixtures.
Drain Waste & Vent, Traps, Clean-outs
Water Supply
Pressure Reduction Valve if> 80 psi
Fixriue & Mounting Heights
Air Gaps @ food prep sinks and condensate drains.
Floor Drains require trap seal protection.
Grease trap requires separate Plumbing Permit
MECHANICAL
Exhaust Fans -ducting, insulation and termination
FRAIVIING
Walls -New interior demising walls
~/~~/~ L~
Ceiling /
Fixture Mounting Heights & Dimensions
Doors -thresholds & lever hazdwaze
LIGHTING
Installing can lights for food display only
Page 1 of 3
Buldiog Permit #BI,DOZ-020
REQUIRED INSPECTIONS APPROVED/DATE
DRYWALL NAILING
Walls
Ceiling / /~
.~/Z~J~OZ (~/
[[ ( `~f ~
FINAL
Fire Department Sign-Off
Health Department Sign-Off
Electrical (L&I)
Plumbing -barrier free design
Mechanical
Building
Exit
Illumination
Door Signage (min. I" letters "This door to
remain locked during Business hours" if
locking hardware on Main Exit)
Barrier-Free
All Doors require lever type hardware.
'/:" maximum thresholds ~ ^ /} n
New uni-sex restroom w/ signage ~/~~
~"~ (l.~
J//
( •
GENERAL CONDITIONS
1. Contractors working on this project are required to have s Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESL) measures shall be installed oo-site and inspected prior
to beginning construction; cal( 385-2294. Measures shall include installation of silt fencing and grsvded
construction entrance (see attached detads). Adjacent rights-of-way shall be kept frce of dirt debris. Soils
ezposed during construction shall be temporarily stab~7ried with mulchrog, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicaut is responsible for protection of adjacent properties.
3. All elements of engincering including nailiug, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed
6. The Building Department is unable to pass final inspection on your project unt,7 Public Works •
requirements Gave been completed and inspected. For Public Works inspection call 385-2294. A
Page 2 a~f 3
soaa~s r~,n usrnoz-0zo
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-
residentialproject.
8. All building permits expire if no progress has been made within siz months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal 8c approval prior to malong changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•