HomeMy WebLinkAboutBLD02-019,.
•
WNamm a3CafzBuiiding
I83 Quiay Shta, Suite 301
Pact Toaeaeod, WA 98368
pltana: (360) 3793108 Fix: (360) 385.7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDO2-O19 Issued: 02/28/02 Parcel Number: 972 600 701
Job Address: 1775 31st Street Zoning: RR=II Type: VV=N Total Occupant Load: 3
Occupancy: R-3 Nature of Work: Construct Single family residence
Owner: John Needham CootraMor: Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMTI'S REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF,OTTTRF,D INSPECTIONS
•
APPROVED/DATE
TEMP EROSION & SDM'T CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
GROUNDWORK PLUMBING
Pressure Test
~1~~/Oy
Pipe joints Exposed
Pipe Bedding
Trap Seal Protection
FooTINGS
Setbacks 3/~~~
Footings
Forms
Reinforcement
Porch Piers
UFER
Ca1148 hours before you dig for utility line locates
I-800.424-5555
Page 1 of 4
Ps®IMBLDOL019
REQUIRED INSPECTIONS
APPROVED/DATE
F ATION
R-10 Insulauo -- __
n n
3/~/D Z (~
_`
Foans
Reinforcement
Anchor Bohs & Washers
Alternate Braced Wall Panel Holdowns
SLAB
R-l0 Insulation
~I
~ /o ~l ~8
Radiant Heat Tubing Z
~,~/
Forms ?/~
-r~ ~/
Reinforcement /
~/ ~b
Anchor Bolts
PLUMBING:
Rough-In (D-V-T & Clean outs) ~~/ ~ /~ n „
/ /
%/
Gas Supply `
1 //
'7
Water Supply
Water Hammer Arrestor @ clothes and dishwasher
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if > 80 psi
Water Heater
Seismic Restraint - 2 places
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
MECHANICAL
Boiler -installation instructions shall be on-site at , / /~~~
`
f
~/
time ojinspection l
l
LPG Fireplace Insert
Whole House Fan
Source Specific Fans
Environmental Ait Exhaust ductutg (w/ backdnift
dampers),
insulation (R-4) and terminus (located 3' from opening)
C
CaA 48 hours before you dig for utility Gne locates
I-800.424-5555
Page 2 of 4
~~
,1-
RF.C1iTiRF.T1 iNCPF.f'TTnN5
1
APPROVED/DATE
Permit#BLD02-019
--- G.--- -- - - - - - -
JJa1Ss
Alternate Braced Wall Panel ~~~~~
Headers
Treated Wood to Concrete
Ceiling/Roof
Truss Positive Connection
Roof Venting -ridge & eave
Windows -escape
Windows U-factor - .75 or better
NFRC window sticker must be on windows and doors
at inspection time
Air Seal
Fresh Air Intake (Window Ports)
Doora U-factor - .40 or better
Rire Blocking
Weather Resistive Barrier
CHIMNEY
Termination
SULATION /L o~
ails-(R=19) 7 ~/ ~y
Ceiling - (R=30 )
Baffies
Vapor Barrier: paint
DRY WALL NAILING
Walls (/,z~DZ-
2'~~
Ceiling
FINAL L~ U.• rANa $ .~~ ~ 1 OZ
Public Works Sign-Off
House Numbers - 5"minimum
Plumbing
MechanicaUHeating
Insulation Certificate
Vapor Barrier Paint Certificate
Smoke Detectors
Final -Building
~ U~~/n~i ,
• Call 48 hours before you dig for utility liue locates
1-800-424-5555
Page 3 of 4
P®itMHLD02-019
~;
1. Contractors working on this project are required to have a Labor Bc Industries contractor's registration
num r and a City business fieense. Failure to provide proof of this documentation prior to work may
result in job shut down wltile this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of s~7t fencing and graveled
construction entrance (see attached details). Adjacent rights-o~way shall be kept free of dirt debris. Soils
erposed daring construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stsbfiized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required suer inspection report corrections are completed.
6. The Bu~7diag Department is unable to pass final inspection on your project until Public Works
requirements have been completcd and inspected. For Public Works inspection call 385-2294. A
7. Final Inspections are required prior to ocnpancy; A Certificate of Occupancy is required for anon-
residential project.
8. All building permits ezpire if no progress has been made within siz months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before yon dig for utility line locates
1-800.424-5555
Page 4 of 4