HomeMy WebLinkAboutBLD02-005w.k,~8xms~wao,g
is~ Q~mcy so-ea, some 3m
Pat TowmmQ WA 98369
PMa: (360 3~v-3zoe Pex: (360 3as~6n
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
TffiS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: ~LD~2-0~5 Issued: 01/18/02 Parcel Number: 974 700 001
Job Address: 2108 West Sims Wav Zoning: CC=II Type: NC Occupancy: NC
Total Occupant Load: NC
Nature of Work: Remodel commercial retail soace. including ezistin¢ restroom to meet ADA requirements.
Owner: McPherson Associates Contractor. Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMTTS REOUIItED:
Electrical -Contact Labor & Industries @ 360-4I7-2702
RE UIRED INSPECTIONS
n
APPROVED/DATE
DEMOLITION
Materials from construction shall be deposited in approved
areas off-site in accordance with all state and local laws
and ordinances
PLUMBING -Barrier Free design required
Rough-In (D-V-T & Clean outs)
Water Supply
Pipe Insulation (R-3)
Pressure Reduction valve if > 80 psi
Fixture and Mounting Heights
MECHANICAL
Bathroom Fan
Environmental Air Exhaust ducting (with backdraft
damper), insulation (R-4) and temunation (3' from
building openings)
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
Ymmit #BLWS-005
REQUIRED INSPECTIONS APPROVED/DATE -
FRANIING
Walls
Positive Connection
Beam
Ceiling
Blocking
Window U-Factor - .40 or better for electric heat
New Exterior Door U-Factor - .60 or better
Threshold -maximum %s "
Fixture Mounting Heights and Dimensions
Fireblocking
Weather resistive barrier
DRYWALL
Walls
Ceiling
INSULATION
Fill exposed cavities
Wall - R-19
Ceiling - R-30 and R-38
FINAL
Property address posted - min. 5 " mrmbers of contrasting
color posted near the main entra»ce of the building and
visible from the street per City ordinance.
Fire Department Sign-Off
Electrical Sign-off (L & n
Barrier Free Access
Thresholds
Door Clearances
Lever Hardware
Plumbing
Wall & Floor Sanitation
Final -Plumbing
Final -Mechanical
Final -Building
Call 48 hours before you dig for utility hue locates
I-800-424-5555
Page 2 of 3
Permit #BLDO'b005
GENERAL CONDITIONS
• 1. Contractors working on this project are required to have a Labor & Industries contractor's re¢istration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings; sodding, etc. once construction is coroplete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspeMion report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspeMed. For Public Works inspection caI13$5-2294. A
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits ezpire if no progress bas been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
bwlding permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. PO5T THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
~J