HomeMy WebLinkAboutBLD02-001' watammtKtlzBaldi~
181 Quiory Shed, 3uitr3Pi
Pat Townsend, WA98368
Phone: (360) 9793208 Fax; (360) 3857675
'^~r . ~r~r+v h1R U!1'i?''1'''TII~Y/AiCF1~TTl
~ CONSTRUCT,ION PERNIIT & INSPECTION RECORD
TffiS CARD MUST BE'POSTED AT CONSTRUCTION SITE
Ca11385-2294 for.Inspection
Permit Number: BLDO2-OOl Issued; 01/08/02 Parcel Number: 965 701'906
Job Address: 922 Benton Street Zoning:- R=II Type: Y^N Oceupaney: R_3
store of Work: Remove eaisti~ cedar roofing on house. install sheeting. felYand comnositic
Owner: Linda Brown Contractor: Hooe Roofing
(385-5653)
GENERAL CONDITIONS APPLY -SEE LAST PAGE
RF.nT1TRF,n 1NCPF.C'.TinNS APPROVEDIDATE
~s
DEMOLITION
All construction debris to be deposited in Jefferson
tKounty Landfill or other location in accordance with
all local, state and federal laws.
SHEATIIING
Nailing requires 8d @ 6" o.c. edges & 12" o.c. field or
I3/a" staples @ 6" o.c. edges and field.
ROOF VENTING
Ridge Vents
Net free ventilation area shall not be less than 1 square
foot per 150 squaze feet of the area of the space
ventilated, unless 50% of the required vent opening
area is provided in the tipper portion,of the roof and
therefore the rate may be reduced to 1 square foot of
venting to 300 square feet of azea vented. Openuegs
shall be covered with corrosion resista~'/." mesh.
ROOFING
Install all roofing material per manufacturer's
specifications and UBC Chapter 15.
•
Call. 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
~~~
PemitMBLppyWl
ruv~.
Smoke detectors required per 1997 UBC (batter
powered OIC)
House Numbers - 5" numbers of contrastingcolor
posted: near main entrance of hoyse and visible from
street per City Ordinance
Final -Building
' ENERAL CONDITION
1. Contractors working on thss project are rejtiiredYo 4ave a1:
number and a City business license. Fannre to pr'ovide`prouf
result in job shat down while this se accomplished.
2. If temporary erosion and sediment control (TESL) measures
and inspected prior to beginning construction; ca11~385=2294.
fencing and graveled construction entrance (see attached cCett
free of dirt debris. Sons ezposed during construction shall be
plastic sheeting, etc. Soils shall be permanently stabilized wit]
construction is complete. Applicant is responsible fo protect
are Yeigaired, they shall be installed on-site
Measures shall include instanatsozivot ant
uls)«Ailjac~ent rights-o~way shall be kept
temparaFSly stabilized with mulching,
i.~eediag, plantings,.soildiug, etc._once
nn'Nr~a~t:ana..1 ........a.A~nn
3. All elemwts of engsneersng includiag nailing, holdowns, sheathing, and alternate braced waD panels + /
(ABWP) regasre inspection prior to cover. ~,,-
4. Owner or gwner's agent shall review and oversee correctson: of any aad sdl deficienries:poted by required
iospectiona
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and suspected. For Public Works inspection.ca11385-2294. ,~
7. Final Inspections are required prior. to occupancy;. a Certificate nf~Occupancy~is:required for anon-
residential project. '
8. All bond'mg permits e>;pire sf no progress has been madewhtiin~,ir%ati~uaths,,or if no inspections-are done
by the Banding Departmem wstbin one year. Call for at -least one;.inspectioa ger year to Ireep yoar
building permit active.
`•, 9. Revisions require submittal & approval prior to malting. cltaages~sn,the Sell Contact the Building
Department @ 379-3208 prior to making changes to the approved plans. :'
'~ 10. POST THIS PERNIIT ON-SITE WITH THE APPROVED 1'L~1S.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2. of 2
!''.
R