Loading...
HomeMy WebLinkAboutBLD96-163_ City of Port Townsend ~U Waten Sleet ~ Port Townsend, WA 98368 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 2205 CHERRY ST Issued: 10/30/96 Parcel No: 985205703 Lot: Block: Project: PERM~T # BLD96-00163 -CONTRACTOR/O WNE ANTONIO SALGUERO 2205 CHERRY ST PORT TOWNSEND, WA 98368 ANTONIO SALGUERO 2205 CHERRY ST PORT TOWNSEND, WA 98368 -PROJECT DESCRlPTIO Residential -Addition (634 sq ft) Conditioned Space. City Contact: Construction TypelOcc UselOcc Load Type of work: ADD Construction Occupancy Type of use: SF - Type f: SN Group t R-3 Load 1: 4 Census Category: 434 Type 2: Group 2: Load 2: Estimated Value: $37,646.00 Type 3: Group 3: Load 3: . Zoning: Ri Type 4: Group 4: Load 4: SI Code: SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS ', Inspection Date Inspector Inspection Date Inspectors --- DEMOLITI ON -Reinforcement jlnsp-See Special Conditions -Anchor Bolts i ~IFOOTINGS ~ ,~ ~ ~~,~ -Vents 'Insp-See Special Conditions -Crawl Access ' , ; -Setbacks -Lat. Rest. Holdown Hrwd -F too ni gs ~ FLOOR FRAMING Z.~~-l(G i Forms 1 -Joists f 'I ' li-Reinforcement -Positive Connection ! -Interior Footing -Anchor Bolts & Washers 'fit; 'FOUNDATION -FDN Vents l 'Insp-See Special Conditions PLUMBING I y f I Wall Insp-See Special Conditions ' ms -Rough-In I Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 3 City of Port Townsend ~ ~S~ WA Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 2205 CHERRY ST Issued: to/3x96 Parcel No: 985205703 Lot: Block: Pro;e°t: PERMIT # BLD96-00163 Inspection Date Inspector Inspection Date Inspector ~-Vents , Zr, S INSULATION -Traps -Floor (R-19) y ~ aG -Drains -Wall (R-19) ~ a6 /P ` 5- -9 -Clean-Outs -Ceiling (R-30) I-Water Supply -Baffles 3- S -Gas Supply VAPOR BARRIER -Hose Bibs (Vacuum Break) .Z -Kraft' °NC ° ';-Pipe Insulation -Crawl Space - 6 Mil Poly -Water Heater RYWALL NAILING 4Z 'MECHANICAL e~~- -Walls btt' ~~ -Furnace -Ceiling "' '-Exhaust ~ FINAL ~ !-Combustion Air Final-Building -Whole House Fan ~'~ Final-Plumbing ~ !-Source Specific Fan ~ ~-~, 9 Final-Mechanical/Heating -Vents Final-Insulation Certificate FRAMING Final-Smoke Det. Througout 'ilnsp-See Special Condftions ~ Final-LPG (Fire Dept.) ',-Walls V. B . p~rrJT I-Ceiling I -Roof ~f ~ ~y~, ~ •`~i sl7 t '- -Attic Venting of "b~ `" d b ,~o~/tb b` e. (! „ -Window U Vafue ` ~,.w- ~d~ ~`~ oo ~ ~t -Air Seal -a ' + ~~~ ~ ~ q j~ r i-Fresh Air Intake (Wall Ports) t,~,Q~ J ~~ r -RafterlTruss Pos. Conn. ~~ -Fire Blocking Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 3 City of Port Townsend Building and Community Development 640 Water Street Port Townsend, WA 98588 BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 2205 CHERRY ST Issued: 10/30/96 Parcel No: 985205703 Lot: Block: Protect: PERMIT # BLD96-00163 SPECIAL CONDITIONS 1 RESTRICTIONS 1 . Demolition materials to be disposed of in areas off-site meeting all qualifications as set forth by state law, local law and other government agencies. 2. North side footings are 8" x 16"; remainder of footings are 6" x 12". 3. -North side stem wall is 8" thick; remainder of stem walls are 6" thick. -Single Alternate Braced Wa0 Panel at kitchen. Header not required to extend through panel. See plans. 4. Plumbing Inspection: -Pressure reduction valve may be required--check water pressure. -Have drain-waste-vent water charged with minimum 10' head pressure for minimum 15 minutes prior to inspection. -Have water piping (hot and cold) pressurized with 50 lbs. psi air or water pressure for minimum 15 minutes prior to inspection. -Have gas piping air pressurized to 10 lbs. psi for 15 minutes prior to inspection. -NOTE: All guages necessary for conducting tests to be furnished by permit holder. -See plans far Aternate Braced Wall Panel in kitchen. Requires inspection prior to cover of any of the construction elements. -Wall ports required in Kitchen antl Bedroom only. GENERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required priorto occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3 1 .~