HomeMy WebLinkAboutBLD96-163_ City of Port Townsend ~U Waten Sleet
~ Port Townsend, WA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2205 CHERRY ST Issued: 10/30/96
Parcel No: 985205703 Lot: Block:
Project: PERM~T # BLD96-00163
-CONTRACTOR/O WNE
ANTONIO SALGUERO
2205 CHERRY ST
PORT TOWNSEND, WA 98368
ANTONIO SALGUERO
2205 CHERRY ST
PORT TOWNSEND, WA 98368
-PROJECT DESCRlPTIO
Residential -Addition (634 sq ft) Conditioned Space.
City Contact: Construction TypelOcc UselOcc Load
Type of work: ADD Construction Occupancy
Type of use: SF - Type f: SN Group t R-3 Load 1: 4
Census Category: 434 Type 2: Group 2: Load 2:
Estimated Value: $37,646.00
Type 3:
Group 3:
Load 3:
. Zoning: Ri
Type 4: Group 4: Load 4:
SI Code:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
', Inspection Date Inspector Inspection Date Inspectors
---
DEMOLITI ON
-Reinforcement
jlnsp-See Special Conditions -Anchor Bolts i
~IFOOTINGS
~ ,~ ~ ~~,~ -Vents
'Insp-See Special Conditions -Crawl Access ' , ;
-Setbacks -Lat. Rest. Holdown Hrwd
-F too ni gs
~ FLOOR FRAMING Z.~~-l(G i
Forms 1 -Joists f 'I
'
li-Reinforcement -Positive Connection !
-Interior Footing -Anchor Bolts & Washers 'fit;
'FOUNDATION -FDN Vents l
'Insp-See Special Conditions PLUMBING
I
y f I
Wall Insp-See Special Conditions '
ms -Rough-In I
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
City of Port Townsend ~ ~S~ WA
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2205 CHERRY ST Issued: to/3x96
Parcel No: 985205703 Lot: Block:
Pro;e°t: PERMIT # BLD96-00163
Inspection Date Inspector Inspection Date Inspector
~-Vents , Zr, S INSULATION
-Traps -Floor (R-19) y ~ aG
-Drains -Wall (R-19) ~ a6 /P ` 5- -9
-Clean-Outs -Ceiling (R-30)
I-Water Supply -Baffles 3- S
-Gas Supply VAPOR BARRIER
-Hose Bibs (Vacuum Break) .Z -Kraft' °NC °
';-Pipe Insulation -Crawl Space - 6 Mil Poly
-Water Heater RYWALL NAILING 4Z
'MECHANICAL e~~- -Walls btt' ~~
-Furnace -Ceiling "'
'-Exhaust
~ FINAL ~
!-Combustion Air Final-Building
-Whole House Fan ~'~ Final-Plumbing ~
!-Source Specific Fan ~ ~-~, 9 Final-Mechanical/Heating
-Vents Final-Insulation Certificate
FRAMING Final-Smoke Det. Througout
'ilnsp-See Special Condftions ~ Final-LPG (Fire Dept.)
',-Walls V. B . p~rrJT
I-Ceiling I
-Roof ~f ~ ~y~, ~ •`~i sl7
t
'-
-Attic Venting of "b~
`"
d b ,~o~/tb b`
e.
(!
„
-Window U Vafue `
~,.w-
~d~ ~`~
oo ~ ~t
-Air Seal -a '
+
~~~ ~ ~ q j~ r
i-Fresh Air Intake (Wall Ports) t,~,Q~ J ~~ r
-RafterlTruss Pos. Conn. ~~
-Fire Blocking
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
City of Port Townsend
Building and Community Development
640 Water Street
Port Townsend, WA 98588
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2205 CHERRY ST Issued: 10/30/96
Parcel No: 985205703 Lot: Block:
Protect: PERMIT # BLD96-00163
SPECIAL CONDITIONS 1 RESTRICTIONS
1 . Demolition materials to be disposed of in areas off-site meeting all qualifications as set forth by
state law, local law and other government agencies.
2. North side footings are 8" x 16"; remainder of footings are 6" x 12".
3. -North side stem wall is 8" thick; remainder of stem walls are 6" thick. -Single Alternate
Braced Wa0 Panel at kitchen. Header not required to extend through panel. See plans.
4. Plumbing Inspection: -Pressure reduction valve may be required--check water pressure.
-Have drain-waste-vent water charged with minimum 10' head pressure for minimum 15
minutes prior to inspection. -Have water piping (hot and cold) pressurized with 50 lbs. psi air or
water pressure for minimum 15 minutes prior to inspection. -Have gas piping air pressurized to
10 lbs. psi for 15 minutes prior to inspection. -NOTE: All guages necessary for conducting
tests to be furnished by permit holder.
-See plans far Aternate Braced Wall Panel in kitchen. Requires inspection prior to cover of
any of the construction elements. -Wall ports required in Kitchen antl Bedroom only.
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required priorto occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3