HomeMy WebLinkAboutBLD96-160. City of Port Townsend stowat.ratr»t
Port rownsend, w~ ~~;
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For inspection
Site Address: 1533 FRANKLIN ST #5
Parcel No: 889708203
Project:
-CONTRACTOR/OWNE
DISCOVERY BAY CONSTRUCTION
P. O. BOX 1410
PORT TOWNSEND, WA 98368
Issued: 11!8/96
Lot: Block:
PERMIT # BLD96-00160
WNE
BARBARA ALLEN
1533 FRANKLIN
Residential addition: 523 square foot Studio/workshoplguest quarters
City Conhd: JLZ Gonstrudbn 7ypa/Oee UseiOec Load
Type orvrork NEW Construction Occupancy
Type or use: SF Type 1: SN Group 1: R3 Load 1: 2
Census Category. 434
Type 2:
Group 2:
Load 2:
Estimated Value: (38,000.00 g
Type 3: Group 3: Load 3:
Zanirp: R3
SI ~: Type 4: Group 4: Load 4:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
FOOTINGS ,~, -Crawl Access Z-
-Setbacks -Beam Pockets ~
-Footings -Lat. Restraint Holdown Hrdw.
-Forms FLOOR FRAMING 2. ~(~-
-Reinforcement -Girders
-LIFER -Joists
FOUNDATION Z - -Shiekt Under Posts
Insp-See Special Conditions -Positive Connection
-Stem Wall -Girder to Concrete
-Forms -Beam Pockets
-Reinforcement -Treated Wood to Concrete
-Anchor Bolts -Anchor Bolts & Washers
-FDN Vents
Call 48 hours before you dig for utility line locates
1-800-424-5555
Pape 1 of 3
City of Port Townsend ~ ~,~
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD ~~
THIS CARD 3 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME •
Call385-2294 For Inspection
Site Address: 1533 FRANKLIN ST #5 Issued: 1lftl/86
Parcel No: liY708203 Lot: Block:
Pr~°`x~ PERMIT # BLD96-00160
Inspection Date Inspector Inspection ate Inspector
PLUMBING L INSULATION ~ 7
-Rough-In -Floor (R-25)
-Vents -Wall (R-19) ~
-Traps -Ceiling (R-30)
-Drains -Baffles ~ I
-Clean-Outs VAPOR BARRIER
-water supply -Iii
-Gas Supply -Crawl Space - 8 Mil Poly
-Hose Bibs (Vacuum Break) DRYWALL NAILING ~ ® (~
-Water Heater -Walls
MECHANICAL 2 ~ -Ceiling
-Exhaust FINAL
-Fresh Air Final-House Number
-Seismic Restraint Final-Building
-Dud Insulation Final-Plumbing
-Whole House Fan Final-MechanicaVHeating
-Water Heater final-Insulation Certificate
FRAMING Final-Smoke Detectors
-Walls Final-LPG (Fire Dept.) ~
-Seismic Anchors
-Ceiling
n
-Roof
-Attic Venting
-Windows
-Window U Value
-Air Seai
-Fresh Air Intake (Wall Pods) ~
Call 48 hours before you dig for utility line locates
1-800-424-5555
J
~~
Paps 2 of 3
City of Port Townsend ~ wA
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 1533 FRANKLIN ST #5 Issued: 11!8!96
Parcel No: 889708205 lot: Block:
Proved: PERMIT # BLD96-00160
SPECIAL CONDITIONS /RESTRICTIONS
1. See engineering notes on plans regarding hold-down requirements
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All buikting permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
~. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
` Call 48 hours before you dig for utility line locates
1-800-424-5555