HomeMy WebLinkAboutBLD96-103City of Port Townsend ~Ta~WAtWJ85
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 1002 TAYLOR ST Issued: 8H5/96
Parcel No: 988802302 Lot: Blook:
Protect: I7Ct~11AIT li BLD96-00103
JOHNSON ROBERT
46-192 NA-KAO PL
iCANEOHE, HI 96744
L
-CONTRACTOR/OWNE
WHITEY JOHNSON
7740 SEAWIND AVENUE NE
POULSBO, WA 98370
ROJECT DESCRIPTIO
Residential remodel: Julie Gleason, new owner, proposes to enlarge the bathroom within the existing footprint of the
house, replace two windows and add a 1-hour wall between the garage and house
Cfij CarMaet: JAN Construction TypslOee UsdOec Load
Type of work ALT Construction ~Y
Type of use: SF Type 7: SN Group 1: R3 Losd 1: 3
Census Categ°ry' 434 Type 2: Group 2 U1 Loatl 7.
stimated Value: 52.000.00
Type 3' Group 3: Loed 3:
Zonirp: R7
SI Cads: Type 4: Group 4: Load 4:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
PLUMBING ,•~ ~{ L~ FRAMING ?). ( .
-Rough-In alts
-Vents -1 Hour Wall
-Traps -Ceiling _
-Drains -Windows
-Clean-Outs -Window U Value
-Wafer Supply / -Air Seal
MECHANICAL 3. ~ , Cf INSULATION ~ r Z -
Insp-See Special Condtions Insp-See Special Conditions
-Seismic Restraint Floor (R-30)
- rce Specific Fan -Wall (R-19)
r Heater Ceiling (R-38)
-18" A.F.F. -Baffles
Cali 48 hours before you dig for utility line locates
1-800-424-5555
pa0.7 art
City of Port Townsend ~ ,~.~„
Building and Cotrmtunity Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Ca11385-2294 For Inspection
Site Address: 1002 TAYLOR ST
Parcel No: 988802302
Project:
Inspection Date Inspector
VAPOR BARRIER ytA"- ,ZZ. /~ ~ ~7
InspSee Spectai Conditions
DRYWALL NAILING
-Walls
-Ceiling
FINAL
Final-House Number
Final-Building
Final-Plumbing
Final-Insulation Certificate
Final-Vapor Bartier Cert.
Final-Smoke Det. Througout
Issued: ti115/96
Lot:
PERMIT #
Bock:
BLD96-00103
- 2-3 otr.~ J- I t~~ ~g"'T'SB G~~
~~
SPECIAL CONDITIONS /RESTRICTIONS
1 . MECHANICAL: If water heater is relocated due !o expansion into garage, water heater is to be
elevated 18" above finished floor, strapped for seismic restraint, and if electric, placed on a
minimum R-10 insulated surface
2. INSULATION: e~derior wall of new bathroom space and ne~v separation wa8 between garage
and bathroom must meet WSEC requirements for electric resistance heat
3. VAPOR BARRIER: No vapor bartier speed on plans
GENERAL CONDITIONS
1. A separate electrical pemtit is required for arty electrical work
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six morphs, or if no inspections have
been made by the Buildup Department within one year. Call for at least one inspection per year to
keep your building permit alive.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Cai148 hours before you dig for utility line locates
1-800-424-5555
vay. as z