Loading...
HomeMy WebLinkAboutBLD96-098City of Port Townsend Po W~`u~`WA9a36a Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD 8r APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 606 EAST PARK AVE Issued: 8!22196 Parcel No: 989800011 Lot: Block: Project: PT BUSINESS PAR. BI_D96-0009 -CONTRACTOR/OWNE BRADLEY HOOVER 606 E PARK AVE PORT TOWNSEND, WA 98368 WNE BRADLEY HOOVER 606 E PARK AVE PORT TOWNSEND, WA 98368 Build 30 "Self-Storage" units as stand alone building addition to Sound Storage. City Contact RS ConstruMion TypefOcc Use/OCC Load Type of vrork: NEW ~ Construction Occupancy ~ Type of use: COM Type 1: 2N -~ Load 1: 30 Group 1: ensus Category: 327 Type 2: Group 2: Load 2: .stimated Value: $125,400.00 Type 3: Group 3: Load 3: Zoning: PUD Type 4: Group 4: Load 4: SI Code: SPECIAL CONDITIONSIRESTRICTIONS APPLY-SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Inspector Inspection Date Inspector TEMP EROSION & SDMT CON Insp-See Special Conditions 'Insp-See Special Conditions -Walls f - ~.r U ~ 'r ~' SIAB -Roof Insp-See Special Conditions DRAINAGE -Setbacks -Per Master Plan -Forms LANDSCAPING -Monolithic Slab/Fdn ~ ~L 7 ~ !, P~J Insp-See Special Conditions -Reinforcement LIGHTING -Interior Footing Insp-See Special Conditions -LIFER FINAL ING Insp-See Special Conditions ,.-See Special Conditions Insp-See Special Conditions ilnsp-See Special Conditions Final-Building Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 2 City of Port Townsend ~ WAS Building and Community Development BUILDER'S PERMIT AND INSPECTION- RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 606 EAST PARK AVE issued: a~2ti9s Parcel No: 989800011 Lot: Block: Project: Pr BuslNess PAR BLD96-00098 SPECIAL CONDITION5/RESTRICTIONS 1 . INSTALL and INSPECT Temporary Erosion and Sediment Control measures per approved plan prior to any other work. 2. See engineer speed concrete design mix, Sheet F-1 of approved plan set. 3 . Walls are concrete tilt-up. See approved plans for reinforcing, roof design, partition panels, eta 4. .Inspect tilt-up wall base grouting. , 5. Welders to be WABO certified per approved plans, Sheet F-1 notes. 6. Landscaping per PUDA requirements. 7. See Exterior Lighting Wattage Budget. • 8. Copy of recorded restrictive covenant tying lots together submitted prior to final 9. All storage units are considered to be Accessible per WAC 51-30. GENERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Calf for at feast one inspection per year to keep your building permit active. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. • Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 2