Loading...
HomeMy WebLinkAboutBLD96-084City of Port Townsend Port Townsend, WA 88388 Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 715 WATER ST Parcel No: 989700704 Project: -CONTRACTOR/OWNE MATHIAS JAMES M POBOX198 PORT TOWNSEND, WA 983680198 Issued: 8/5/96 lot: Block: BLD96-00084 WNE MATHIAS JAMES M POBOX198 PORT TOWNSEND, WA 983680198 Change of use from Master Cleaners to Retail. Rebuild front wall. GWB interior. New LPG furnace, Barrier Free front and rear entrances w/ voluntary BF parking in rear. City Contact: JAN Construction Type/Occ UserOec Load Type of vrork: ALT Construction Occupancy Type of use: COM Type 1: 5N Group 7: M1 Load t: 40 Census Category: 437 Type 2: Group 2: Load 2: .stimated Value: $35,000.00 Type 3: Group 3: Load 3: Zoning: C3 - SI Code: Type 4: Group 4: Load 4: SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE REQUIRED INSPECTIONS Inspection Date Inspector Inspection Date Inspector'; Insp-See Special Conditions -Exhaust I Insp-See Special Conditions -Heat Ducts FOUNDATION q dL iC ~ ~ -Duct Insulation Insp-See Special Conditions -Heat Source Equip. & Controls -Stem Wall FRAMING -Reinforcement Insp-See Special Conditions -Anchor Bolts Insp-See Special Conditions PLUMBING Insp-See Special Conditions -Gas Supply -Walls MECHANICAL -Ceiling Insp-See Special Conditions -Roof iee Special Conditions -Attic Venting _p~ace -Windows Call 48 hours before you dig for utility line locates 1-800-424-5555 Page t of 3 .City of Port To Building and Community BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Cail 385-2294 For Inspection Site Address: 715 WATER ST Parcel No: 989700704 Project: Inspection Date Inspector -Window U Value -Window Safety Glazing -Air Seal -Fire Blocking INSULATION -Fill Exposed Cavities VAPOR BARRIER -Paint DRYWALL NAILING g 22 -Walls -Ceiling FINAL Insp-See Special Condftions Final-Building Final-Barrier Free Access Final-Plumbing Final-Meth anicaUHeating Final-House Number Final-Vapor Barrier Cert. Final-LPG (Fire Department) Final-Fire Department Sign-off -Smoking/Non Area Signage -Fire Extinguishers Issued: tilOl96 Lot: Brock:.:. BLD9B-00084 .~ .:,. i SPECIAL CONDITIONS /RESTRICTIONS 1 . Demolition disposal shall be made in approved areas off-sfte meeting qualifications as set forth by the State, local law and other govemmeM agenaes. Call 48 hours before you dig for utility line locates 1-800-424-5555 ._ Papa2or3 . ~ City of Port Townsend ~; wAe~ Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 715 WATER ST Issued: 8/5/96 Parcel No: 989700704 Lot: Block: Project: BLD96-00084 SPECIAL CONDITIONS /RESTRICTIONS 2. Pedestrian protection is required for work which impedes and/or endangers pedestrian or vechile R.O.W. movement. Call for inspection of pedestrian protection measures prior to any work. 3. Inspect new curb at new front wall for horizontal resteel and C poxied anchor hogs. 4. Check furnace room for combustion air requirements. 5. Fresh air requirements accomplished by openings in building per UBC. 6. Steel moment resisting frame requires a Special Inspection per UBC 1701.5.5.1 & 2. Inspector to be listed in curcent WABO Special Inspection Agency and Inspector Resister, Ed. 96-02, July 1, 1996. 7. See Engineered plans for plywood nailing on roof sheathing. 8. See engineered knee brace connections for parapet. 9. Barrier Free parking sign at building comer on front of building in addition to sign at parking space per WAC 51-30. ~NERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. 2. Reinspections are required after any corcections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your building permit alive. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3 ~,_ u