HomeMy WebLinkAboutBLD96-083City of Port Townsend Port Townsend?Wq 98368
t`
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8~ APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address; 2333 SAN JUAN AVE Issued: 12/11/97
Parcel No: 958502301 Lot: Block:
Project: BLD96-83R3
-CONTRACTOR/OWNER
QUIMPER UNITARIAN UNIVERSALIST
FELLOWSHIP
PO BOX 1967
PnRT TnwnrRFNr) WA GR36R
OWNE
QUIMPER UNITARIAN UNIVERSALIST
FELLOWSHIP
PO BOX 1967
-PROJECT DESCRIPTIO
Revision No 3: Enclose entry breezeway, fully on south side and partially on north side.
City Contact: RNS Construction Type/Occ Use/Occ Load
Type of work: NEW Construction Occupancy
Type of use: COM Type 1: SN Group 1: A3 Load 1:
Census Category: 319 Type 2: Group 2: load 2:
Estimatetl Value: $2,500.00
Type 3: Group 3: Load 3:
Zoning: R1
SI Code: Type 4: Group 4: Load 4:
REQUIRED INSPECTIONS
Inspection Date Inspector
,FRAMING Z ~~ r . ~ ~s~I~
FINAL
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page i of 2
r/~ ~~ ~,~.~-q~l
,~.- ~ 3-R~ City of Port Townsend Po W ~~~d WA>,>~
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2333 SAN JUAN AVE
Parcel No: 958502301
Project:
QUIMPER UNITARIAN UNIVERSALIST
FELLOWSHIP
PO BOX 1967
Construct new church
Issued: 7124/96
Lot: Block:
BLD96-00083
WNER-----
QUIMPER UNITARIAN UNIVERSALIST
FELLOWSHIP
PO BOX 1967
City Contact: JAN Construction TypelOcc UselOcc Load
Type of work: NEW Construction Occupancy
Type of use: COM Type 7: 5N Group 1: A3 Load 1:
Census Category: 319 Tyce 2: Group 2: Load 2:
Estimated Value: 5192,869.60
Type 3: Group 3: Load 3:
Zoning: R1 -
SI Code: Type 4: Group 4: Load 4:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page t of 4
Inspection Date Inspector Inspection Date Inspector
Insp-See Special Conditions FOUNDATION
Insp-See Special Conditions -ReinforcementR~' Gi~~ ~ g r~~ ~ ~'
EROSION & SEDIMENT CONTROL Insp-See Special Conditions
;GROUNDWORK PLUMBING FLOOR FRAMING ~ /~ /
(FOOTINGS/SLAB ~~ (~ 1' ` -Girders
Insp-See Special Conditions -Joists
-Footings g 'S -Positive Connection
-Forms ~ ~ -Treated Wood to Concrete
-Reinforcement -Anchor Botts 8 Washers
-LIFER ~ 2, ~ PLUMBING
(Slab ~~~ ~' ?~ ~~z ~ -Rough-In
ulation -Vents
~rior Footing -Traps
• City of Port Townsend Bad lNater Street
_- ~.. Pat Townsend, WA 88388
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD ;~
THIS CARD 8 APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection ;~
J
Site Address: 2333 SAN JUAN AVE Issued: 7124!96 ~ ~'.
Parcel No: 958502301 Lot: Block: ~`"'
Project: BLD96-000$3 ~.~
Inspection Date Inspector Inspection Date Inspector
-Drains K7 /~. ~~ ~ -Baffles ~ ~ ~ ' . ~' S
-Clean-Outs VAPOR BARRIER
-Water Supply -Paint
-Hose Bibs (Vacuum Break) ~ DRYWALL NAILING ~ ~+ ~~S
-Barrier-Free Required _.~~ -Walls ~ ;
',-Pipe Insulation Ceiling i'
-Pressure Reduction Valve -~"7 S DRAINAGE
IMECHANiCAL "' -Engineered Plan ~
i Water Heater ~ Insp-See Special Conditions
~ --sh Air
~ - PARKING
rce Specific Fan LANDSCAPING
-Heat Source Equip. & Controls LIGHTING
Insp-See Special Conditions -Equipment Controls
FRAMING SANITARY SEWER
-Walls WATER LINE
-Ceiling HYDRANTS
'-Roof FINAL
-Windows Insp-See Special Conditions
-Air Seaf Insp-See Special Condtions
-In WaII.Penetrations Final-Building ~ ~~ A "
Insp-See Special Conditions Final-Barrier Free Access !~
Insp-See Special Conditions Final-Plumbing
INSULATION ~;/~L 7 ~~ ~ Final-MechanicaUHeating
-Slab (R10) ,r Final-House Number
!-Floor (R-30) ~` Final-Vapor Banier Cert.
!-Ceiling (R-38) \ Final-Insulation Certificate
ng (R-30) Final-Public Works Sign-off
Call 48 hours before you dig for utility line locates
9-800-424-5555
`U
~~,~
Page z or a
City of Port Townsend Port ownsend tWA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2333 SAN JUAN AVE
Parcel No: 958502301
Project:
Inspection Date Inspector
Final-Fire Department Sign-off
-Smoking/Non Area Signage
I-Fire Extinguishers
-Exit Lighting
Issued: 7124198
Lot: Block:
BLD96-00083
SPECIAL CONDITIONS /RESTRICTIONS
1 . Prior to any construction per engineered drainage plan: 1. Create 50' construction access
ramp with 4" (min.) quarry spalls leading to 24th Street. All traffic is to use this access. 2.
Stormwater detention basin must be constructed prior to clearing and grubbing and will serve
as a siltation basin during construction. Provide field verification of infiltration capacity used in
design calcs for infiltration basin. Perform test at location of detention basin. 3. Swale to
detention basin constructed prior to building activity. All runoff to detention basin via this
Swale. Note straw bale barrier requirement in Swale. INSPECTION REQUIRED FOR ABOVE
REQUIREMENTS PRIOR TOANY CONSTRUCTION.
2. Separate permit required for Manual Fire Alarm System.
3. Test concrete for slump and strength (7 & 28 day breaks) by WABO certified special inspector~~- j i
listed is WABO Register, Ed: 96-02, July 1, 1996. Copy of test results to Port Townsend L ~' ~ 2i (v q~
Building Department. Any deficiencies requiring correction are the responsibility of the owner
or owner's agent.
4. Walls are ENER-GRID Wall System. See engineering for resteel placement, lintel design and
top plate connections.
5. Prior to Mechancial inspection complete and submit as revision NREC requirements re: HVAC
& WSVIAQ.
6. Truss plan to be submitted as revision prior to Framing inspection for Building Department
approval.
7. Prior to Framing inspection, submit details of required landscape buffers at parking lot
perimeter.
8. Prior to Final Drainage Inspection: Upon completion of final site grading and placing of gravel
paving, the detention basin shall be re-excavated to remove all silt and debris. Re-excavation
shall be to approximately 3" below final grade to allow placement of 3" topsoil prior to final
hydroseeding. Inspection required.
9. Post occupant load per UBC.
10 . Interior lighting is perscriptive path per NREC.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
City of Port Townsend ~W~e-Sereet
Port Townsend, WA 88368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 2333 SAN JUAN AVE Issued: 7!24/96
Parcel No: 958502301 Lot: Block:
Project: BLD96-00083
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy
4. All building permits expire'rf no progress has been made within six months, or'rf no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permft active. '
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
u
Call 48 hours before you dig for utility line locates
1-800-424-5555