HomeMy WebLinkAboutBLD96-082City of Port Townsend ~w~s~ WA 88388
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME S a(p
Call 385-2294 For Inspection Gp lD~~ 4
p,~~s ~l-slal
Site Address: 776 MADISON ST Issued: 7H 7196 fi
Parcel No: 988800504
Project:
LITTLE JENNIFER A
JAMES F LITTLE
605 D
Construct accessory dwelling unit (ADU)
Lot: Block:
PERMIT # BLD96-00082
WNE
LITTLE JENNIFER A
JAMES F LITTLE
605 D
City Contact: JAN Construction Type/Occ UselOcc Load
Type of work: NEW ConsWdion Occupancy
Type of use: SF Type 1: SN Group 1: R3 Load 1: t
Census Category: 101 Type 2: Group 2: Load 2:
Estimated Value: $27,420.00
Type 3: Group 3: load 3:
Zoning: Rt
SI Cade: Type 4: Group 4: Load 4:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
GROUNDWORK PLUMBING ~~~-~ -Vents ~ (,. (~ ~~ ~~_S
FOOTINGS/SLAB .•, uZ -Traps
-Footings -Drains
-Setbacks -Clean-Outs
-Forms -Water Supply
-Reinforcement -Hose Bibs (Vacuum Break) '
-LIFER ~ °~ -Pipe Insulation
Porch/Bay Piers !~~ !, -Pressure Reduction Valve
-Insulation Insp-See Special Conditions
-Anchor Bolts / ~ Insp-See Special Conditions
'I-Interior Footing ~~ MECHANICAL G -u--(' 1~-`~
MBING -Water Heater
~
.,gh-In
/
~
-Whole House Fan ,
/-'
Call 48 hours before you dig for utility line locates
1-800-424-5555
.~
Page 1 of 3
City of Port Townsend PortTavnsand, WA 88968
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 776 MADISON ST Issued: 7117/96
Parcel No: 988800504 Lot: Block:
Proje«: PERMIT ~ BLD96-00082
2
C
Call 48 hours before you dig for utility line locates
1-800-424-5555
Inspection Date Inspector Inspection Date Inspector
-Vents ~~-~ S FINAL
Insp-See Special Conditions sp-See Special Conditions 1
FRAMING Final-Building
-Walls Final-Plumbing
-Ceiling Final-Mechanical/Heating
-Roof Final-Smoke Detectors
-Vents Final-House Number
i-Windows Final-Vapor Barrier Cert.
-Air Seal Final-Insulation Certificate
-In Wall Penetrations ,
-Fresh Air Intake (Window)
I-Rafter Positive Connection _ 6-~(6 4~S
-Fire Blocking
Insp-See Special Conditions i ,(,~
INSULATION ,'Lf~
-Slab (R10)
-Wall (R-19)
-Ceiling (R-38)
-Ceiling (R-30)
,-Baffles _C-C((~ ~S
VAPOR BARRIER
-Paint
DRYWALL NAILING r f Z
-waus
-Ceiling
DRAINAGE
i
Jlnsp-See Special Conditions
Page 2013
City of Port Townsend ~yTeownsend. WA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8~ APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 775 MADISON ST Issued: 7117/96
Parcel No: 988800504 Lot: Black:
Pr°'e«: PERMIT # B'-°9s-ooosz
SPECIAL CONDITIONS /RESTRICTIONS
1 . Test for excessive water pressure (>80 PSI). Pressure reduction valve may be necessary.
2. R-10 required under hot water heater.
3. Whole house fan and source specific are the same: 75 CFM located in bath.
4. Impervious surface drainage associated wRh ADU addition to be collected via tightline piping
and surface discharged across property towards Lincoln and specifically directed away from
ADU or any other structure and the neighboring property at Madison and Lawrence.
5. ADU house number is 776 Madison.
GENERAL CONDITIONS
A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca~14S h0UlS b6f0le you dig for utility line locates
1-800-424-5555
page3 0> 3
~~