HomeMy WebLinkAboutBLD96-054Pat TowrwrM, WA 99~Bi City of Port Townsend "°Wa"rs""t Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2284 For Inspection Site Address: 2102 WILSON ST Issued: 6119/96 Parcel No: 848306402 Lot: Block: Project: PERMIT #BLD9s-ooosa -CONTRACTOR/OWNE WNE MONICA ROBERT F MONICA ROBERT F EVENELL MONICA EVENELL MONICA 1213 27TH ST 1213 27TH ST -PROJECT DESCRIPTIO New single-family dwelling with celport, porches, basements and decks City Collect: JAN Construction TypdOee UsalOee Load Type of voorlc: NEW ~ Conatnwtion Y Type of use: SF Typa t: SN Graq t: R3 Load 1: 4 Census Category: 107 Typs 2: Group 2: Load 2: Estimated Value: 5153,017.79 Type 3: Group 3: Load 3: Zoning: R1 51 Cada: Type 4: Group 4: Load 4: SPECIAL CONDITIONSIRESTRICTIONS APPL~\YG SEE L~STtP~GE ;~1~~ REQUIRED INSPECTIONS ~~ Inspection Date Inspector Inspecti n Date Inspector GROUNDWORK PLUMBING GL FOUNDATION f ~a FOOTINGS/SLAB Insp•See SpeciaFConditions -Footings ~? ~ p ~ _ Insp-See Special Conditions j -Setbacks FLOOR FRAMING ~ . rC- -Stem Wall -Girders -Fortes -Joists -Reinforcement -Shield Under Posts -LIFER •1 < -Positive Connection Porch/Bay Piers -Treated Wood to Concrete Slab -Anchor Bolts & Washers -Insulation Insp•See Special Conditions or Footing See Special Conditions PLUMBING -Rough-In ; (~ ~~ Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 7 of 3 City of Port Townsend `"'""`""~` Pat TownarW, WA f1p6t Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD ~~ THIS CARD S APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 2102 WILSON ST Parcel No: 9~i306102 Project: _ Inspection ~ Date ~ ~ . (D_~I Traps -Water Supply -Hose Bibs (Vacuum Break) -Pipe Insulation Insp-See Special Conditions MECHANICAL Heater istion Air -Whole House Fan Insp-See Special Conditions FRAMING ~ ~ , ,. 3• Wall Panels Issued: p79/tli lct: Block: BLD96-00054 Date In I ~'~ insp-See Special Condtions Insp-See Special Condtions INSULATION ?J , i?• 9~ ~_ _ -Slab (R10) -Wall (R-19) -Ceiling CR-3) -Baffles VAPOR BARRIER ~ - " ~~ -4 Mil Poly DRYWALL NAILING ~ -Walls ~.Z . -Ceiling ~ -Interior Braced Wall Panels Insp-See Special Conditions i Seal Wali Penetrations esh Air Intake (Wall Ports) •r0~ ~_ ACS er Positive Blocking -InfiRration Trench -Catch Basin Per Apprvd Plans FINAL~ir~ a-,~ Detectors e Number (Fire Department) ~tion Certificate Works Sign-off 47 6 Ca1148 hours before you dig for utility line locates !~G® l~,'(~` $Sf~A.r 4~-`~tJkt~- W~i-~ 7-800-424-5555 ~ci~{e!~, ~a,,~,. , ~~' ' ` Pg~2M3/~~jj/ r p~ n A /Ny~~ yam/ ~' ~ , ~~ ~}c noa:Q~n,~` nu;~f.~S~Q7 ~VV ~V ~/~, ~ ~ I ~ + 1 IjC City of Port Townsend ~ ~;~ wase3sa f Building and Community Development BUILDER'S PERMIT AND INSPECTION RECORD THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME Call 385-2294 For Inspection Site Address: 2102 WILSON ST Issued: 6H 9196 Parcel No: 948306402 Lot: Black: Project: BLD96-00054 SPECIAL CONDITIONS /RESTRICTIONS 1 . FOOTING: Slab and footing insulation may be required ~ basement entry door area 2. FOUNDATION: Quad-lock system 3. FOUNDATION: See engineered plans for holdown placement 4. FLOOR FRAMING: floor framing inspection may be done at framing inspection 5. PLUMBING: check pressure for possible pressure reduction valve requirement 6. MECHANICAL: remote located continuous operating fan 7. FRAMING: basement not constructed to ADU standards 8. FRAMING: see engineered plans for shear wall nailing; inspection required piror to cover 9. DRYWALL: see engineered plans for GWB nailing ~NERAL CONDITIONS 1. A separate electrical permit is required for any electrical work. 2: Reinspedions are required after any corrections are complete. 3. Final Inspections and approvals are required prior to occupancy. 4. All building permits expire if no progress has been made within six months, or if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your building permk alive. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates 1-800-424-5555 P~aa3