HomeMy WebLinkAboutBLD01-248Watamaa d Ka1zB~tdiog
181 Quiory 6traA, 3uita 301
Pok rowveed, WA 98368
P6ooe: (360) 399-3208 Fsx: (360) 365-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION STTE
Call 385-2294 for Inspection
Permit Number: BLDO1-248R-2 Issued: 04/19/02 Parcel Number: 957 702 602
Job Address: 710 Cass Street Zoning: R_II Type: VV=N Occupancy: R 3
Nature of Work: Remove eaistin¢ cedar roofin¢ on house, install sheeting, felt and composition
sbinQles, and provide adequate ventilation.
Owner: Jonathan LanQdon
Contractor. All About Building
(385-2139)
GENERAL CONDITIONS APPLY -SEE LAST PAGE
RF,OiJiRED INSPECTIONS
r`
APPROVED/DATE
DEMOLTI'ION
All construction debris to be deposited in Jefferson
County Landfill or other location in accordance with
all local, state and federal laws.
SHEATHING
Nailing requires 8d @ 6" o.c. edges & 12° o.c. field or
1 '/," staples @ b" o.c. edges and field.
ROOF VENTING
Ridge Vents
Net free ventilation area shall not be less than 1 squaze
foot per 150 square feet of the area of the space
ventilated, unless 50% of the required vent opening
area is provided in the upper portion of the roof and
therefore the rate may be reduced to 1 square foot of
venting to 300 square feet of area vented. Openings
shall be covered with corrosion resistant'/." mesh.
ROOFING
Install all roofing material per manufacturer's
specifications and UBC Chapter 15.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
PermitfBLU01 -]48
FINAL
Smoke detectors required per 1997 UBC (battery
powered OK)
House Numbers - S" numbers of contrasting color
posted near main entrance of house and visible from
street per City Ordinance
Final -Building
ENERAL CONDITION
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
n m r and s City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. If temporary erosion and sediment control (TESC) measures are required, they shall be installed on-site
and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt
fencing and graveled constrnMion entrance (see attached details). Adjacent rights-of--way shall be kept
frce of dirt debris. Soils ezposed during construction shall be temporarily stabilized with mulching,
plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, eta once
construMion is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass fmal inspection on your projeM until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
7. Final Inspections are required prior to occupancy; a Certificate of Uccnpanry is required fora non-
residential project.
8. All building permits ezpirc if no progress has been made within siz months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal dt approval prior to making changes in the field. Contact the Building
Department ~ 379-3208 prior to making changes to the approved plena
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800.424-5555
Page 2 of 2
•
Waterman and Katz Building
181 Quincy Street Suite 30l
Port Townsend, WA98368
Phone (360) 3793208 Fax (360) 385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
TffiS CARD MUST BE POSTED AT CONSTRUCTION STTE
Call 385-2294 for Inspection
Permit Number: BLDU1-24$R-1 Issued: 02/25/02 Parcel Number: 965702602
Job Address: 710 Cass Street Zoning: RR=II Type: V_N Occupancy: RR=3
Total Occupant Load: 2
Nature of Work: Revision #1: Add dormer/windows
Owner: Jonathan Lanedon Contractor: Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RE UIRED INSPECTIONS
APPROVED/DATE
FRAMING:
Walls ~j/ /~/~
,3~2 0
0 ~ (/`
Ceiling /
` `-'[
Window -escape
Window U-factor - .70 or better
Air Seal
Fire Blocking
INSULATION 3
pA
.
/}J
Walls (R-19) /z
~
L
CO/ (
J/
Ceiling (R-30) (
DRY WALL NAILING
Walls
Ceiling
FINAL -see original inspection record
Final -Building
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
Building Pamil #BLDOI-248R-1
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
reeistrstion number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of way shall be kept free of dirt
and debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic
sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspeMion is required after any corrections are completed.
6. The Building Department is unable to pass final inspection on your projeM until Public Works
requirements have been"completed and inspected. For Public Works inspection call 385-2294; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has been made within six months, or ii no inspeMions are
done by the Building Department within one year. Call far at least one inspection per year to keep
your building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2
r W atertnan and Kmz Building
- 181 Quincy Sfrat Suite 30!
Part Towtuend, Wp98368
Plwne (360) 379-3208 Fax (560) 383.7673
CITY OF PORT TOWNSEND
•
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDOI-24g Issued: 01/24/02 Parcel Number: 965702602
Job Address: 710 Cass Street Zoning: RR=II Type: VV=N Occupancy: RR=3
Total Occupant Load: 2
Nature of Work: Remodel recreation room into ADU
Owner: Jonathan LanQdon Contractor: Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RRt1TTTRF.T) TN.CPF.fTTONC
APPRnVF,D/DATF.
PLUMBING
Rough-In (D-V-T & Clean Outs) ~~/ . ~
v
(//~ ~.
Water Supply !
/
Gas Supply
Water Hammer Arrestor @ dishwasher
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
R-10 under in garage
Seismic Restraints
Pressure Relief Valve Drain to exterior
MECHANICAL
LPG Stove
Bath/Whole House Fan
Kitchen Fan
Environmental Air Exhaust ducting (with backdraft
damper), insulation (R-4) and terminus (located 3'
from openings)
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
~-
Building Permit #BLDOI.248
REQUIRED INSPECTIONS APPROVED/DATE
FRAMING:
Walls
Ceiling
Air Seal
Fire Blocking
INSULATION
Fill any exposed cavities
DRY WALL NAILING
Walls
Ceiling
FINAL
LPG
House Numbers - 5" high minimum
Smoke Detectors
Final -Building 'n
tl~~~D
GENERAL CONDITIONS
1. Contractors working on this projeM are required to have a Labor & Industries contractor's
reeistration number and s City business license. Failure to provide proof of this documentation prior t~
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construMion; ca11385-2294. Measures shall include installation of silt fencing aad
graveled construction entrance (see attached details). Adjacent rights-of way shall be kept free of dirt
and debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic
sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, snd alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspeMions.
5. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspeMion on your projeM until Public Works
requirements have been completed and inspected For Public Works inspection call 385-2294; a
.minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
r
Building Permit #BLDO1.24g
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Ca11 for at least one inspection per year to keep
your building permit active.
9. Revisions require review and approval rior to making changes in the field. Contact the Building
Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
C~
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
~~