HomeMy WebLinkAboutBLD01-233ware,~~x,~~ia,~
psi ~r street, suu 30(
PoM1 Towmmd, WA 98368
Phone: (360) 379-3208 Fmr. (360) 385-7675
i
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO1-233 Issued: 12/27/01 Parcel Number: 968-500-065
Job Address: 4166 Jackman Street Zoning: Lvnnesfield PUD Type: VV=N Occupancy: R-3
Total Occupant Load: 4/2 Nature of Work: Construct sinele-family residence w/ ag rage
Owner: Harold & Edie Erickson
Contractor: Camabell Construction
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
• RE UIRED INSPECTIONS
APPROVED/DATE
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence
Drive Off Matto restrict sediment from leaving
the site
FOOTINGS
Setbacks
G ~~~bZ-
Footings
Forms
Reinforcement
Interior Footings
Porch Piers (
- `~/,lJY1~GLvY-~Gf T,/ ~~J/
UFER [! ~
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Pmnil # BLDOI-2i3
REQUIRED INSPECTIONS APPROVED/DATE
FOUNDATION
Engineered Holdawns
Stem Wall
Forms
Reinforcement
Beam Pockets
Anchor Bolts w/ 2" x 2" x 3/16" washers
Foundation Vents -10 required
Crawl Space Access
/ //~D
lG/
FLOORFRAMING -Engineered BCI joist plan
shall be on-site at time of inspection
Girders ~Z Z/O Z
Joists
Blocking
Shield under Posts
Positive Connection
Girder to Concrete
Beam Pockets
Treated Wood to Concrete
Anchor Bolts w12" x 2"x 3116" washers
Crawl Space Access
PLUMBING:
Rough-In (D-V-T & Ctean outs) ~~~ /D
!/
'
Water Supply J
'~~~
Gas Supply -t~
Water Hammer Arrestor @ clothes washer and
dishwasher
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
R-10 under
I8" A. F. F.
Seismic Restraint - 2 places
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
1
J
Ca1148 hours before you dig for utility line locates •
I-800-424-5555
Page 2 of d
Pmnit#HLD01.233
REQUIRED INSPECTIONS APPROVED/DATE
•
•
MEC ICAL
G Fve
Whole House Fan -Utility Room !~ /~~~ y,
Source Specific Fans !!
/ !/
Environmental Air Exhaust ducting (w/back draft !
dampers), insulation (R-4) and terminus (located 3'
from opening into building)
FRAMING
Engineered Shear Walls
Walls
~/J~~ ~~
Ceilings
Roof
Rafter Positive Connection
Attic Venting - eave & ridge
Windows -escape
Window safety glazing
Windows Ufactor - .45 or better
NFRC sticker must be on windows, doors
& skylights at inspection time
Air Seal
Fresh Air Intake (Window or Wall Ports)
Doors U-Factor - .40 or better
Skylights - .68 or better
Fire Blocking
Weather Resistive Barrier
CHIMNEY
Termination
INSULATION
Floor (R=25) l j
i/~~1/
~~ ~ ~GZ~,
Walls (R=19) j
Ceiling (R-38 attic/R-30 vault)
Baffles
Vapor Barrier: paint
Crawl space - 6 mil black poly
DRY WALL NAILING
Walls
Ceiling
Enclosed Usable Space Under Stairs
Engineered Interior Shear Walls
Garage/House Occupancy Separation
• Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
r~x~,no~.zas
FINAL
Public Works Sign-Off
LPG
House Numbers
Plumbing
MechanicaVHeating
Insulation Certificate
Vapor Barrier Paint Certificate
Smoke Detectors
Final -Building
5~iz~o z
3~Zg167~
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number snd a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled
constrnMion entrance (see attached details): Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspeMion call 385-2294. A
minimum of twenty-four hours notice is required. Public Works auoroval must be received urior to
scheduling the Building Deuartment's final inspeMion.
Final InspeMions are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspeMion per year to keep your
building permit active.
Ca1148 hours before you dig for utility line locates
I-800-424-5555
Page 4 of 4
•
Permit k BLI70I-233
- 9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
• Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 5 of 4