HomeMy WebLinkAboutBLD01-220Waterman &. Kau Buildiry{
181 Quinry Slree4 Suite 301
Port 7ownaend, WA 98368
Phone: 360379J208 Fa:360J85-7675
CITY OF PORT TOWNSEND
C~
U
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDOI-220 Issued: 11/16/01 Parcel Number: 948 305 802
Job Address: 1630 Gise Street Zoning: R-II Type: V_N Occupancy: RR=3
Total Occupant Load: 4 Nature of Work: Set New Manufactured Home
Owner: Evelvn Brewer Contractor:Washineton Home Center WAINS#0078
****Installer: See Attached Installer Tae****
GENERAL CONDITIONS APPLY -SEE LAST PAGE ~,n ~t rssU~
SEPARATE PERMITS REQUIRED: l///~/01~
Electrical -Contact Labor & Industries @ 360-417-2702 ~
NOTE: Set-up manual shall be on-site at time of inspection.
RRf1TiTRRT) TNCPFC'TTONC
APPROVFn/nATF,
TEMP EROSION & SEDIMENT CONTROL
See general condition #2
Silt Fence as needed
Drive Off Mat to prevent sediment from leaving
the site
FOOTINGS/SLAB
Setbacks
Forms
Reinforcement
FLOOR FRAMING (prior to skirting)
Anchors ~~ /~~~ ^ n
// c
,L %
~
/
Steel Support Piers -Load-stamped and installed /~
/
/
/
per marn~facturer's installation manual; clearance
of IS"mire from Irnvest point of I-beam and the
ground or footing for min. of 75 % of area under
home w/ I2 "min. elsewhere unless installation
marmal specifies; otherwise area around home
graded to provide runoff away from home.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page I of 3
PermB gBLD03-220
REOUIRF.D iNCPF('Ti(lNC ~uunnvcnrn~m>c
' ------
PLUMBING: ~V •L/L/LA1L'
Water Supply -Main shut-off valve (port or ball valve)
installed in water supply piping prior to connection to /
~Z(l / 6
home, min. '/. "diameter, same as supply pipe
Pressure Reduction Valve if> 80 psi
Hose Bibs (backflow protection required)
Pipe Insulation -Outside & in crawl space
Pressure Test -100 p.s. i. for 15 minutes
Pressure relief valve drain - to exterior of skirling,
exhaust dawmvard between 6"and 24"above ground
Drainage Piping -sloped min. /J.' per foot
MECHANICAL
Ducts & Duct Insulation
Dryer Exhaust -vented to outside. Extension into crawl ,~ n
~~Zr1~~2 (l+~''/
r
space rewires venting through skirting with no dips;
follow dryer manufacturer's instructions; total combined
length of ducting not to exceed 14' w/ 2-90° elbows
VAPOR BARRIER
6 mil black poly ground cover (not required where area C ~ ^~O~
c~
under home is concrete slab floor with a minimum
thickness of 3-%z inches)
FINAL
Public Works Sign-Off
Electrical (L & I) Sign-Off
House Number -minimum 5" numbers
Plumbing
Mechanical
Final -Building
No Notes or gaps greater than %"allowed in skirting.
Crawl space ventilation per installation manual @
1/150 (10 required), located close to corners, on at least
two opposing sides for cross ventilation.
Crawl space access must provide access to all areas
under home, minimum 18"x 24 ", covered with virryl,
pressure treated wood or metal.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Permit #BLDOl-220
GENERAL CONDITIONS
i 1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Soils exposed during construction shall be
temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with
seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of
adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
• 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Ca11 for at least one inspection per year to keep your
building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department at 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
n