HomeMy WebLinkAboutBLD01-217City of Past Townsend
Waterman $ Katz ~ildiog
181 QninaY Shcet, PortTownmd, WA98368
(360) 379-3208 Faz (360) 385.7675
CITY OF PORT TOWNSEND
N
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 355-2294 for Inspection
Permit Number: BLDOl-217 Issued: 01/15/02 Parcel Number: 948302905
Job Address: 1432 Hill Street Zoning: R-III Type: VV=N Occupancy: U-1/R-3
Total Occupant Load: add 1/1 Nature of Work: Residential Addition
Owner: Forrest and Diana Daniel Contractor: Discovery Bav Construction
GENERAL CONDTTIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REOUIItED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF,nTTiRF.D iNSPECTION5
APPROVED/DATE
EROSION CONTROL
Sweeping of paved surfaces may be required to
eliminate the tracking of dirt and debris onto City
rights-of--way
FOOTINGS
Setbacks / ~j
~( ~~QZ-~ '~/
Footings
Forms
Reinforcement
Interior Footings
LIFER
FOUNDATION
Stem Wall
Forms
Reinforcement
Anchor Bolts
Vents - 3 required
Crawl Access
Beam Pockets
ABWP holdowns @ garage
Call 48 hours before you dig for utility line locates
1-500-424-5555
Page 1 of 3
Building Pemut #BLDOI.217
RE UIRED INSPECTIONS
APPROVED/DATE
FLOOR FRAMING
Girder
~'~~Q 2i
Joists "(
Blocking
Shield under Posts
Positive Connection Post-to-Beam
Beam Pockets
Treated Wood to Concrete
Girder to Concrete
Anchor Bolts & Washers
FRAMING:
Walls
Attic Venting -gable end & soffit
~
)~
M n
n
J
/
Ceilings ~
/
l v/~ l
lf
/
Roof -engineered truss plan to be on-site at time of
inspection
Posts, Beams and Headers
Windows -escape
Windows Ufactor -see WSEC worksheet
NFRC windww sticker must be on windows
at inspection time
Air Seal
Truss Positive Connection
Fire Blocking
Weather Resistive Barrier
INSULATION
Wall (R-21)
~~~/~~~~
Floor (R-38) 7
Ceiling (R-49
Battles
Vapor Barrier: paint
6 mil black poly in crawl space
DRY WALL NAILING
Walls ~ j~ OZ
f ( /~jj
(_%t
"
Ceiling t( (
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
N
Building Permit #BLn91-217
FINAL
House Numbers -check for 5" numbers
V. B. Paint Certificate ~~~ s~/~~ ( U
Insulation Certificate J I
Smoke Detectors throughout existing construction: one in
each sleeping room and In each area/hallway leading to
sleeping rooms with a minimum of one on each floor
Final -Building
GENERAL CONDITIONS
I. Contractors working on this project are required to have a Labor & Industries contractor's
reeistration number and a City business license. Failure to provide proof of this documentation
prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and
inspected prior to beginning construction; ca11385-2294. Measures shall include installation of
silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way
shall be kept free of dirt debris. Soils exposed during construction shall be temporarily
stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with
seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for
protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall
panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted 6y
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294.
A minimum of twenri-four hours notice is reauired. Public Works aooroval must be received
prior to schedufine the Building Deaartment's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a
non-residential project.
8. All building permits expire if no progress has been made within six months, or iP no inspections
are done by the Building Department within one year. Call for at least one inspection per year
to keep your building permit active.
9. Revisions require review and approval by the Building Department. Contact them at 379-5086
prior to making changes in the field.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
• Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
r-
=.-.
~J
• /