Loading...
HomeMy WebLinkAboutBLD01-211wetelmsn 8<xet~anitai~ I el Qumry Street, Suite 301 Pw[ To~wsend, WA 98368 Phone: 0360) 379-3208 Fax: (360) 385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLDO1-2118-6 Issued: 03/17/03 Parcel Number: 989 705 602 Job Address: 842 Washington Street Suite 101 Zoning: C_III Type: V-1HR Occupancy: A-3 Total Occupant Load: TBD Nature of Work: Install above ground grease trap for 35 seat "Galatea Cafe". Owner: Bill Wolcott Tenant: Lora Wood Contractor: Lora Wood GENERAL CONDTITONS APPLY -SEE LAST PAGE SEPARATE PERMTTS REOUIItED: Electrical -Contact Labor & Industries @ 360-417-2702 NOTE: See Building Permit #BLDOl-211 for other inspections. GREASE TRAP -Inspection and testing required for all rough-in prior to cover FINAL Final -Plumbing Cal! 48 hours before you dig for utility line locates 1-800-424-5555 Page I of 2 Pemdt # HLD01-211R-6 1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached detat7s). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall paneLv (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. A minimum of twenri-four hours notice is reauired. Public Works approval must be received prior to scheduline the Buildine Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon- • residential project. 8. A-I building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval prior to making changes in the Tield. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. CJ Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 2 CITY OF PORT TOWNSEND ~, O RIC HITCHEN INSPE TION TE T C R C TE THIS CARD MUST BE POSTED AT CONSTRUCTION SITE CALL 385-2294 FOR INSPECTION Permit Number: Issued: 0142. ' Date: G ~ ~ 3 Job Address: Owner/Proprietor: • 3 6 Nature of Work: Use of Building: Contractor: Contractor State License Number: $I'~iirRRD rNCPF('Ti(lNS ~ System orientation/installation in accordance with mfr's/UI. listing and City permit l~~ Appliances properly covered with correct nozzle(s) (appliance mfr's listing) .~ Duct and plenum covered with correct nozzle(s) .~' Positioning of nozzles ,_,~e Nozzle covers in place (where required) -'~~ Fusible links within rated temperature requirement ~e~ n • `~ Hood/duct penetrations sealed with weldor UL listed device ~y ~ / ~~ Cylinder pressure gauge in proper range (if gauged) C~O~ ~- ~/!~'~`'' .~' Hydrostatic test date of cylinder current (C02 cartridge exempt) ~-t1-' -~ Inspect cylinder mount(s) 5t9 Check travel of cable(s) Cable piping and conduit properly bracketed Proper separation between fryer(s) and devices with surface flames ~ Proper surface to filters clearance Exhaust fan in operating order ~s+ Filters in proper orientation Fuel shut-off in "on" position for operation/test ^ Fan warning sign on hood '~o be Gl'v'+ti ~ Manual release and location proper ^ Personnel instructed in manual operation of system -~ Class K Fire extinguisher within 30 feet and tagged properly .~ 40-B:C Portable Fire Extinguisher available and tagged properly N~j+. ^ Electrical panel properly labeled for shunt-trip function and manual reset, if applicable ^ Other:.-( Inspector. Date: 838 Date: A('('F,PTAN('_F. TF.CT •--~~ Automatic Trip Test t!~ ~ ~r^^~~ ~8 Manual Trip Test -~ Fue]/Power disconnect for all hooded appliances/outlets (with manual reset) ry/f1'O Hood protection system monitored by premises automatic fue alarm system ^ Certifica ' n/ rvice tag on system Inspeoh~~`1~ z--~ _ _ Date: U r" d F4 c.>G~'7C..G. MS'S --~~yC Inspector: Date: C:\WINDOWS1Desktop\Tom's File Cabinet\Forrns & TemplateslCommercial Kitchen\Commerical Kitchen Inspection & Test Certificate.rtf 3/13/Ol ~ixe.~t.rc 5r4c' ~aq. ,~1J(vrT ~A'/~4057' ~ ~GN/TD"le- Permit # BLD01.21 lR-4 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLDOl-2118-4 Issued: 03103!03 Parcel Number: 989 705 602 Job Address: 842 Washin¢ton Street Zoning: C-III Type: V 1-hour Occupancy: A_3 Total Occupant Load: NA -shaft only Nature of Work: Revise one-hour hood shaft construction Owner: Bill & Dvana Wolcott Lessee: Laura Wood 301-3616 Contractor TBD GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REOUIItED: Electrical -Contact Labor & Industries @ 360-417-2702 Hood and Duct Hood Suppression RRnTTTRFTI TNSPF.CTTONS APPROVED/DATE FRAMING Shaft DRYWALL/NAII.ING One-hour shaft -deleting exterior drywall; construct with metal studs and (2) layers S/8" Type X gypsum board on the inside FINAL Final -Building Exterior shaft chase shall be painted body color of building ,, J ~,' f ~ GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's re¢istration number and a City business licenses. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. Permit # BIDQI-2I1R4 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site snd inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsibk: for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall- panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shad review snd oversee correMion of any and al! deficiencces noted by required inspections. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294; a minimum oftwenty-four hours notice is required. Public Works approval must lie received prior to scheduling the Building Department's final inspection. 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. S. All building permits expire if no progress has been made within siz months, or if no inspections done by the Building Department within one year. Cal! for at k;ast one inspeMion per year to keep y bul7ding permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Building and Community Development Waterman & Katz Building 301 Quincy Street Suite 301 Port Townsend, WA 98368 Phone: (360) 379-3208 Fax: (360) 385-7675 CITY OF PORT TOWNSEND • CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: $LDd1-211R-3 Issued: 02/14/03 Parcel Number: 989 705 602 Job Address: 842 Washinnton Street Zoning: C-III Type: V 1-hour Occupancy: AA_3 Total Occupant Load: NA -hood & duct only Nature of Work: Install hood. duM & fan Owner: Bill & Dvana Wolcott Leasee: Lora Wood Contractor: TBD 301-3616 GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 Hood Suppression MECHANICAL Type IHood -manufacturer's installation instructions shall be on-site at time of inspection Appliance/Exhaust Interlock Exhaust Outlet Clearance Type Duct Gage Duct Ioints/Seams - contirmous liquid-tight weld Grease Duct Supports - no penetration of duct walls Duct Slope -minimum %r: 12 Duct/Enclosure Separation Duct/Enclosure Shaft Cleanouts Air Velocity: 1500 - 2500 fpm Duct/Combustible Clearance -18 "; 3 "from non-combusfibles Hood Flashing Duct Insulation -make-up air: R-3.3 Grease Filters Canopy Hood LPG Kitchen Stove ~ ~~~~~~ ~ r Permit # BLUO1-2118-3 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this docuroentatiogprior to work may result in job shut. down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294; a minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. 8. All building permits expire if no progress has been made within siz months, or if no inspections are done by the Building Department within one year. Ca11 for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ONSITE WITH THE APPROVED PLANS. Permit # BLDOl-211R-1 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: $LDO1-211R-I Issued: Ol/30/03 Parcel Number: 989 705 602 Job Address: 842 Washin¢ton Street Zoning: C-III Type: V 1-hour Occupancy: AA=3 Total Occupant Load: NA -shaft only Nature of Work; Construct one-hour hood shaft Owner: Bill & Dvana Wolcott Leasee: Laura Wood 301-3616 Contractor TBD GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REOUIItED: Electrical -Contact Labor & Industries @ 360-417-2702 Hood and Duct Hood Suppression RE UIRED INSPECTIONS APPROVED/DATE FRAMING Shaft O.IzJ pp~~ 1"~~' a, ~ ~ log DRYWALL/NAILING 3 g ~~Q;s Ol~\ One-hour shaft - 2 layers 518" Type X gypsum board ~~ ( ~ ~ ~ 3 F~nvAL Final -Building Exterior shaft chase shall be painted body color of building l _~' GENERAL CONDITIONS I. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. Permit # BLDOI.211R-1 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shalt be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and akernate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required aker any corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294; a minimum of twenty-four hours notice is required Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspeMion per year to keep yoi~ building permit active. 9. Revisions require review and approval prior to making changes in the Feld. ContaM the Building Department 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Permit # BLDOld11Rd t ~1 ~J i CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD TffiS CARD MUST BE POSTED AT CONSTRUCTION STTE Call 385-2294 for Inspection Permit Number: BLDG 1-211R-2 Issued: 02/04/03 Parcel Number: 989 705 602 Job Address: 842 Washington Street Zoning: C-III Type: V 1-hour Occupancy: A_3 Total Occupant Load: 57 Nature of Work: Interior remodel to convert space to dining establishment Owner: Bill & Dvana Wolcott Leasee: Laura Wood Contractor: Same as Owner 301-3616 GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REOUH2ED: Electrical -Contact Labor & Industries @ 360-417-2702 Hood Ducting, & Exhaust Fan Hood Suppression Plumbing -Grease Trap Sign Permit RF,nTTTRF,D TNSPECTTONS APPROVED/DATE PLUMBING Contractor to verify that waste and water pipes are sized to accommodate additional kitchen frxtures Drain Waste & Vent Water Supply Air Gaps @ food prep sinks and condensate drains Grease trap requires separate plumbing permit with trap sized per accompanying talcs MECHANICAL Type I Hood requires separate mechanical permit ~/~r~ ~ ~ !~ FRAMING Walls - if walls are not structurally attached @ ceiling, connection must be designed; revision required ~ ~ ~~ , cI (./~ ~ Positive Connections ~ Air Seal Fireblocking Doors - %: "max. thresholds; swing in direction of travel with panic hardware Pecmilq BI UO1d11R•2 RE UIRED INSPECTIONS APPROVED/DATE DRYWALL/NAILING Walls Ceiling 7j FINAL - no occupancy permitted until push/pull hardware or main door latch is approved by HPC subcommittee Fire Department -exit aisle requirement of 36 "for seating' area ~~ ~~~~ Electrical (I, & I) / Health Department -~ ~~~ Plumbing Mechanical Building Exit Signage and Illumination (all exit doors) Door Signage ("THIS DOOR TO REMAIN LOCKED DURING BUSINESS HOURS" if locking hardware on main door) Push/Pull (no latch) hardware @ main doors Post Occupant Load Final -Building J GENERAL CONDITIONS t~ 1. Contractors working on this project are required to have a Labor Fi Industries contractor's reeistration number and a C~ business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Soils ezposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced waD panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspeMion on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294; a minimum oftwenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. ~. - ~ ,+ Pmnit # BLD01-2llR-2 .~ 1 • 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at (east one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. CantaM the Building Department 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. • .. ~ ;: E C~ Waterman & Katz Building 181 Quincy Street, Suite 201 Port Townsend, WA 98368 Phone: (360) 379-5083 Fax: (360) 385-4290 • CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLDO1-211 Issued: January 11, 2002 Parcel Number: 989-705-602 Job Address: 842 Washington Street Zoning: C-III Type: V 1-hour Occupancy: R-1/ M Nature of Work: Renovate/upgrade existing one-story commercial structure and add second floor residential (11 apartments) 13,202 SF conditioned space. Owner: Bill & Dyana Wolcott Contractor: Vern Garrison 385-5112 379-0548 SEPA Conditions Apply -See attached required mitigation measures for LUPO1-058 GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries (360.417.2702) Street & Utility Development Permit Plumbing Permit for groundwork, rough-in & finish. (Submitplans for review, including pipe sizing and fixture schedule). Mechanical Permit (Submit plans for review). REQUIRED INSPECTIONS APPROVED/DATE TEMP EROSION & SDM'T CONTROL See General Condition No. 2-inspection required prior to foundation work Ls- ~ ~~ ~UwG9 Gf/s'gTt-~;,rb i ~~~l~r~Y FOOTINGS-Engineered Design (f/~f~7~i01Z 2r~Q®Z Setbacks Footings Forms Reinforcement ~/r~'/OX, 2/ OZ /in 'fY' ~Ry-l~l- ~ ~/ (t~9ytQ o'%Y Retaining Wall ,~n ~~ u/gGL 3~S~BLC.// LIFER / 111 FOUNDATION-Engineered Design ~~i -~F~-: ,., ,,, ~~j.,~ ~,,.,;~r~., t'/1 ~~v Stem Wall / Forms E,.,¢rfrs ~31/py~ Reinforcement Grade Beams and Soil Anchors ~fc7' fvpr rt/~sTasorrr~ ~17~sy Anchor Bolts w/ 2" x 2" x 3/16" square washers Holdown hardware Retaining Wall Call 48 hours before you dig for utility line locates 1-800-424-SSSS Page 1 of 4 ~- ~. C C~ REQUIRED INSPECTIONS APPROVED/DATE Pumit N BLDOI-211 sLAB R-10 rigid insulation Reinforcement Interior Footing Anchor Bolts Column Bases FLOOR FRAMING Manufacturer's approved wood joist floor system layout required on site for inspection Field verification ofground floor connection to 2nd floor diaphragm by structural engineer (Skeet S2.6). Joists Beams Posts Positive connection PLUMBING q ~0/O~ Deferred submittal: Not part of this permit. ` Roof Drainage Sheet A2.4 MECHANICAL Deferred submittal: Not part of this permit. / ~f~~~i Location of rooftop units to be verified by engineer. FRAMING HPC Certificate of Review for modification to //JJ ~ ~ypOK. Zi B ~-~ q/~O/OL exterior elevations, lighting, signage, & exterior support equipment & improvements in the Taylor / ~ ~ ~~~~r92/ < St. ROW required prior to commencing framing. Walls 1 hour exterior walls ([j 1-hr building Engineered shear walls (sheet S-2.1) Holdowns per schedule on sheet S2.1 Roof Roof venting per sheet A2.4 Attic access not required (< 30"} Roof drainage per sheet A2.4 Parapet: Upper 18"of parapet wall to be non- combustible and 1-hr construction throughout. Ceilings Windows U-factor.90 for retail, .46 for residential (NFRC sticker required) Safety glazing Letter from structural engineer ojrecord stating all work constructed according to approved plans. REQUIRED INSPECTIONS APPROVED/DATE Call 48 hours before you dig for utility line locates I-800-424-5555 Page 2 of 4 • _~ r • Permit 4 BLDOI-211 FRAMING (continued) Doors-.60 U-factor for retail, .40 for residential Air Seal Fire-blocking Fire-stopping of penetrations Stairs-interior & exterior Weather resistive barrier INSULATION t~,Urr ~~ 9 ~lLf~~ ~- Slab (w/foundation permit) Wall R-11 for retail, R-19 for residential Y GlDS GOZ-- ~ t ~JZ~~ Roof R-30 Vapor barrier paint-certification letter F~ - ~0/'~/OL ! required at Final DRYWALL NAILING J,~1IS ZQ3 2(~ Zl ~ q/~~ Jn~- I / Walls Type V 1-hour building. All walls aze 1-hr ~/~J 1~.> [ C1 t ~,~Z 241{_ Z(l `~ ~~' t ~ except within individual dwelling units and walls in retail ortion interi nonbe rin n . g p or a Enclosed space under interior stairs _ ~~~ti /~~ ~ ! j/ G~ ~~ Z! 0 ~ `/! Ceilings ~ G 1-hour LIGHTING See approved plans & NREC Lighting Summary Daylight zones & switching Lighting power allowance PARHING 1 van accessible space required for retail use only. 1 van accessible space required for residential barrier- free dwelling unit only, ('t'otal of 2) FINAL Revalue project for additional permit fees ~ ~~ ,~ L~'~ , ~/~~C'_ ~~//!!),~ Property address / , Fire Rated Doors Emergency Lighting & Illuminated Exit Signs Final Plumbing Barrier free required Floor, wall & baseboard per UBC Sec 807 Final Mechanical WSVIAQ Insulation certificate Vapor barrier paint certificate Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 ' Permit N BLDOL211 ` ~ ~ REQUIRED INSPECTIONS APPROVED/DATE Provide copy of recorded joint parking and access agreement with abutting property owner in a form acceptable to the City Attorney Barrier free access Final Fire Department Final Public Works Final HPC Conditions & Sign Permit-Call Jeff Randall @ 379-3208 x1124 Final Electrical (L&I) Final Building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to schedulin¢ the Buildin¢ Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval prior to making changes in the field. Contact the Building and Community Development Department at 385-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4