Loading...
HomeMy WebLinkAboutBLD01-202Wstefmm and Katz Building 181 Quincy 36ed Suife 30I PoR Toxreend, WA98368 Ph~o (360) 379-3208 Fax (360) 383.7673 CITY OF PORT TOWNSEND ~V CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Pernut Number: BLDO1-202R-1 Issued: l0/31/02 Parcel Number: 985 208102 Job Address: 704 V Street Zoning: R_II Type: V_N Occupancy: RR=3 Total Occupant Load: No Chanee Nature of Work: Revision #1: Add twa dormers with windows Owners: Jeff and Lisa Blohm Contractor: Owner GENERAL CONDTI'IONS APPLY -SEE LAST PAGE SEPARATE PERMITS REOUIItED: Electrical -Contact Labor & Industries Qa 360-417-2702 REQUIRED INSPECTIONS APPROVED/DATE FRAMING: Walls ~" ~ '~/~(i/ '/z" CDX Plywood Sheathing with Nailing per G attached engineering Ceiling Window U-factor - .40 or better Air Seal Fire Blocking Ridge Beam LVLs -per attached engineering INSULATION Walls (R-19) (R-30) Ceilin ., /' ~ L.,F L--~U Z-- g DRY WALL NAILING waus ///~/O 3 Ceiling / FINAL -see original inspection record ' Final -Building Call 48 boors before you dig for utility line locates 1-800-424-5555 Page 1 of 2 Building Permit #BLDOI-7MR•1 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor .~ Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may resole in job shut down while thks ks accomplished 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of sik fencing and graveled construction entrance (see attached details). Ady'acent rights-of way shall be kept free of dirt and debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements Gave been completed and inspected. For Public Works inspection call 385-2294; a minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Departments final inspection. 7. F'mal Inspections and Certificate of Occupancy are required PRIOR to occupancy. 8. All bnt7ding permits expire if no progress has been made within siz months, or if no iatpectioos are done by the Building Department within one year. Call for at least oae inspection per year to keep your building permit active. 9. Revisions. require review and approval prior to making changes in the field Contact tbe Bmlding Department st 379-5086 rior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before yon dig for utility tine locates 1-800-424-5555 Page 2 of 2 • City of Pat Tow~uend Waterman & [Getz Building 181 Quinry Street, PoRTownaen4 WA98368 (360) 379-3208 Fax (360) 385.7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION STI'E Call 385-2294 for Inspection Permit Number: BLDO1-202 Issued: 10/26/01 Parcel Number: 985208102 Job Address: 704 V Street Zoning: R_II Type: V_N Occupancy: RR=3 Total Occupant Load: add 2 Nature of Work: Residential Addition Owner: Jeff Blohm Contractor: Same as Owner GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 REQUIRED INSPECTIONS APPROVED/DATE EROSION CONTROL Sweeping of paved surfaces may be required to eliminate the tracking of dirt and debris onto City rights-of--way FOOTINGS Setbacks Footings Forms Reinforcement -n r ~~r~ (~ S~ ~~~ ~' b G ~/ I J 0 Interior Footings _ J UFER FOUNDATION Stem Wall ~Ort/p ~ ~, /f Z/O ~ / !/ ` Forms 'T Reinforcement Anchor Bolts Vents - 2 required Crawl Access Beam Pockets Call 48 hours before you dig for utility line locates I-800-424-5555 Page 1 of 4 Building Pmnil #BLDOI-202 REQUIRED INSPECTIONS APPRnVF,nmATF. FLOOR FRAMING TJI joist plan shall be on-site at time of inspection Girder ~ Zl ~ r d ~ ,~ /! ( J V Joists I l l ~ Blocking Shield under Posts Positive Connection Post-to-Beam '4D0/Y'(a W ~/, /Q~ (~ Positive Connection Post-to-Foundation Wall (if applicable) Beam Pockets Treated Wood to Concrete Girder to Concrete Anchor Bolts & Washers PLUMBING ~/ Rough-In (D-V-T & Clean Outs) '~ ~ Water Supply Pipe Insulatlon (R-3) Pressure Reduction Valve if> 80 psi MECHANICAL Bath/Whole House Fan ~J 2~0 /RL (V nn j„'j / Environmental Air Exhaust ducting (with backdraft l ( ` damper), insulation (R-4) and terminus (located 3' from openings) FRAMING: Walls ij Fj~• d / nn / ~~37i ("I ~ Attic Venting -ridge & roof I . Z C C i Ceilings Roof Posts, Beams and Headers Windows Ufactor - .40 or better NFRC window sticker must be on windows at inspection time Air Seal Fresh Air: window or wall port required Rafter Positive Connection Fire Blocking Weather Resistive Barrier i Call 48 hours before you dig For utility line locates • 1-800-424-5555 Page 3 of 4 Building Permit kBI.D01-202 REOUTRED INSPECTIONS APPROVED/DATE INSULATION Wall (R-19) ~-- ___~ ._____----...------. ~.u ~~ Yom:; ~ o:,w 1~ ~~ ' o i Floor{R-30 ~ Ru~.G. Ceiling (R-30 in vault) Baffles Vapor Barrier:battsand/orpaint ~w~:e ~ ~ ~ ~>~r-,h c.~,x~, or1~ ~ ~ ~ ~ ~ 6 mil black poly in crawl space "~' ' ~ a'~' DRY WALL NAILING "~'e ~il~orv~- z ~ L Walls r Ceiling FINAL House Numbers -check for 5" numbers Plumbing Mechanical V. B. Paint Certificate Smoke Detectors throughout existing construction: one in each sleeping room and in each area/hallway leading to sleeping rooms with a minimum of one on each floor Final -Building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a Ciri business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspeMed prior to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4 Building Permit #HLD01.402 6. The Building Department is unable to pass foal inspection on your project anti{ Public Works requirements have been completed and inspected. For Public Works inspection ca11 38 5-2 294, press 3. A minimum of twenri-four hours notice is required Public Works approval must be 7. Final InspeMions are required prior to occupancy; A Certificate of Occupancy is required for a non-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval by the Building Department. Contact them at 379-5086 prior to making changes in the field. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 5 of 4