HomeMy WebLinkAboutBLD01-198
Walertnen &. Katz Building
181 Qtinry Stred, Suite 301
Pat Towm+e++d, WA%368
Phone: (360) 3793208 Farz: (360) 379fi923
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDO1-19g Issued: 10/15/Ol Parcel Number: 948-003-805
Job Address: 1248 31st Street Zoning: RR=7I Type: VV=N Occupancy: R-3
Nature of Work: Construct 400 so. ft. Studio
Owner: Matt & Marv Beth Kite Contractor: T & M Construction
(Mike Davis: 385-3806)
GENERAL CONDITIONS APPLY -SEE LAST PAGE
RFl1TTTRx'Tl TNCPFf'TT(1NC
A PPR f)VF,11/nATF,
TEMPORARY EROSION & SEDIMENT CONTROL
See General Condition No 2
MONOLITHIC SLAB
Setbacks
~ ~~~~
Forms
Reinforcement
Insulation - R-10
bolts w 2"x 2" x 3/16" washers
UFER
PLUMBI G
Rough-In (drain, vents, traps, clean outs)
Water Supply
~ ~~~~
Hose Bibbs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if water pressure > 80 psi
Water Heater
Seismic Restraint
Pressure relief drain to exterior; 6" - 24" above grade
R-10 under
MECHANICAL
Bath Whole House Fan with timer
Environmental Air Exhaust ducting (with backdraft
damper), insulation (R-4) & terminus (3' from openings)
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
Pem~it # BLi701.198
RE UIRED INSPECTIONS APPROVED/DATE
FRAMING
Engineered truss plan to be on-site at time of inspecfion „n
Walls 17 ~ ~ ~
(
]~/
Treated Wood to Concrete //
~
Ceiling/Roof
Attic Venting - eave & ridge
Windows U-factor - .43 or better
Door U-factor - .20 or better
Air Seat
Fresh Air -window ports
Blocking
Truss Positive Connection
Firebloclung
Weather Resistive Barrier
INSULATION
Slab-RIO
Walls - R-19 ~~p,~,~,,.~
~~~g~ , ~'" d ~3l „/)
GI.GlYA' ~ ~ Z ~ t~ 1 (i
l/
Ceiling R-38 l
Bafiles w/ 1" air above
Vapor Barrier: paint
DRYWALL/NAII.ING /
/
Walls ~
~
~~
/ c
Ceiling L
FINAL
House Numbers @ main house - 5" minimum
Plumbing
Mechanical
Insulation Certificate
Vapor Barrier Paint Certificate
Smoke Detector @ studio
Final -Building
GENERAL CONDTI'IONS
I. Contractors working on this project are required to have a Labor & Industries contraMOr's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
_1
.J
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Pv'eil#BLDOId98
2. Temporary erosion and sediment control (TESC) measures sha116e installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance. Adjacent rights-of--way shall be kept free of dirt & debris. Soils eaposed during
construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is
responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is required Public Works approval must be received prior to
scheduline the Buildine Department's final inspection.
7. Final Inspections are required prior to occupancy. A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within su months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
• 9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
I-800-424-5555
Page 3 of 3
~'