HomeMy WebLinkAboutBLD01-192
Waarmaa 8 Katz Building
lal Qat~9 Street, Saih 201
Port Totmrmd, WA 98368
Phone:360J79.5083 Fu360-3853390
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11379-4450 for Inspection
Permit Nnmber: BLDO1-192
Job Address: 1650 Cherry St.
Total Occupant Load: 2
Owner: Vernon Garrison
Issued: 11/OS/Ol Parcel Number: 984-904-301
Zoning: RR=II Type: VV=N Occupancy: RR=3 -
Nature of Work: Single-family Dwellin¢
Contractor: Same as Owner
~; ca 5 ~~~
~-I-t, r-z~ vt~~,
~ ./+,~
GENERAL CONDITIONS APPLY: See last page
SEPARATE PERMITS REQUII2ED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
Street & Utility Development Permit -Contact Deputy City Clerk 360-379-5083
REOIJIl2ED INSPECTIONS
APPROVED/DATE
TEMP EROSION & SEDIMENT CONTROL
See General Condition #2 & attached Erosion &
Sediment Control Practices.
Silt Fencing
Crraveled construction entrance required to prevent
dirt and sediment from leaving the site
Inspection required prior to construction.
FOOTINGS
Setbacks
Footings (Sono Tubes)
Reinforcement (per engineering)
Interior Footings (Sono Tubes)
Porch Piers (same as house)
UFER
CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 4
REQUIItED INSPECTIONS
Building Permit p01-192
APPROVED/DATE
FOUNDATION
Same as Footing
Connectors specified per engineer
SLAB
N/A
FLOOR FRAMING
Premier Structural Panels (specs on-site)
Attachments per Engineering
PLUMBING
Rough-In (D-V-T & Clean outs)
Water Supply
Water Hammer Arrestor @ clothes and dishwasher
Gas Supply
Hose Bibbs - backflow protection required
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
Seismic Restraint - 2 places
Pressure Relief Valve drain to exterior, terminate
6" 24" above ground
Freeze protect all under-floor water pipe & DWV
MECHANICAL
LPG Boiler/water heater
Hydronic in-floor heating
Whole house ventilation
Whole house fan in master bath
Wall ports (Loft window "G')
Source Specific Exhaust Fans @ bathrooms (SOcfm),
kitchen (100 cfm) and utility room (50 cfm)
Environmental air exhaust ducting (with backdraft
dampers), insulation (R-4)-and terminus (3' from
openings into building)
7
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
REQUIRED INSPECTIONS
Building Permit #01-192
APPROVED/DATE
FRAADIVG
Premier Structural Wall Panels (specs on-site)
Roof Trusses (specs on-site)
Attic venting - gablelsoffit
Posts, beams and headers
Windows -escape
Windows -safety glazing -
Window U-factor - .60 or better
NFRCsticker must be on windows at time of inspection
Doors - .40 or better
Air Seal
Fireblocking
Weather Resistive Bamer
.INSULATION
Walls (Premier Panel)
Ceiling (Premier Panel)
Baffles
Vapor Barrier - (Premier Panel)
DRYWALL NAILING
waus
Ceiling
Enclosed Usable Space under Stairs
FINAL ,
Public Works Sign-off '~~~ (Z~/~ ^, -~-f~ ~
~ Z.>.,2r~ I n S~~ Y, ~ 2t'X~S,
LPG
House Numbers- 5"numbers minimum
Plumbing
MechanicaUHeating
Insulation Certificate
Vapor Barrier Paint Certificate
Smoke Detectors
Final -building
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
Building Permit #O1-192
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
contractor's resistration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on~ite and
inspeMed prior to beginning construction; call 379-4450. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspecfion prior to cover.
4. OwnQr or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Jefferson County Building Department is unable to pass final inspection on your
project until Public Works requirements have been completed and inspected. For Public
Works inspection call 379-5083. A minimum of twenty-four hours notice is required.
Public Works anoroval must be received urior to scheduline the Buildine Department's
final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the
Deputy City Clerk at 379-5083 prior to making changes to the approved plans.
10. POST THIS PERMiT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4
~,