HomeMy WebLinkAboutBLD01-190Waterman & Katz Bwlding
181 Quinry 54ee1, Suite 301
P«t 7ownvend, WA 98368
Phone'(360)379-3208 Fsc: (360)385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERNIIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO1-190 Issued: 9/20101 Parcel Number: 931200105
Job Address: 1137 Van Ness Street Zoning: RR=II Type: V-N Occupancy: R-3
Nature of Work: Construct New Residential Foundation Occupant Load: NC
Owner: Claudia Cutsinaer
Contractor: Dave Johnson Construction
GENERAL CONDITIONS APPLY -SEE LAST PAGE
NOTE: FOUNDATION PERMIT ONLY
RF.nTTTRF,T) TNSPF.CTIONS
APPROVED/DATE
TEMP EROSION & SDM'T CONTROL
See General Condition No. 2 -install on-site as needed
during construction to prevent sediment from leaving the
site and to eliminate tracking of soil onto the street
FOOTINGS
Setbacks - NC
l Z~~ z~g/
Footings
Forms
Reinforcement
I 'or footings
FOUNDATION
Stem Wall
Forms
`f~~O~® I
Reinforcement
Anchor Bolts w/ 2" x 2" x 3/16" square washers
Vents
Crawl space access
Girder to Concrete
Beam Pockets 1 ~~
~f//QC/ ~J~
%~' l '
Positive Connection
Treated Wood to Concrete
Shield under Posts
6 mil black poly
Call 48 hours before you dig Tor utility line locates
1-800-424-5555
Page 1 of 2
Pmnit q BLD01-I90
FINAL
House Number -check for 5" numbers
Smoke Detectors required throughout existing
house per 1997 UBC: one in each sleeping room
and in each area hallway leading to each sleeping
room with a minimum of one detector on each floor
1 Z~!°Z
Final -building
GENERAL CONDTI'IONS
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for proteMion of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-229'4. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Departments final inspection.
7. Final Inspections are required prior to occupancy; a Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within sia months, or if no inspections are done
by the Building Department within one year. Call for at {east one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Obtain revisions from the
Building Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
!~
Ca1148 hours before you dig for utility tine locates
1-800-424-5555
Page 2 of 2