HomeMy WebLinkAboutBLD01-181Wazemun a 1CatzBuiltiog
181 Quvxy Stag, Snub 301
Pat Tarmaxl, WA 93366
Phone: (360) 3793208. Fax: (360) 3811675
•
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD01-181R-1 Issued: i1-27-O1 Parcel Number: 948-902-806
Job Address: 479 N Street Zoning: R_II Type: VV=N Occupancy: R-3/U-I
Total Occupant Load:2/2 Nature of Work: Garage revisions: install exhaust fan:
revise window layout: install floor drain in slab
Owner: Bill Matthews /Marian Roh
C,
Contractor: Owner
GENERAL CONDTITONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RFniTiRFn iNSPF,CTiONS
APPROVED/DATE
TEMP EROSION & SEDIMENT CONTROL
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
SLAB
Floor Drain
~ ~ ~ ~~~
Groundwork Plumbing
Pipe Bedding
Trap Seal Protection
MECHANICAL
Exhaust Fan
FINAL -see original inspection record
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
Permit#BLD01-Ie1R-1
1. ContraMors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished
2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspeMion prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduline the Buildine Department's final insceMion.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non-
residential projeM.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2
Waterman & Katz Building
1 BI Quincy Sveet, Suite 301
Port Townarnd WA98368
Poone: (360)379-3208 Fez: (360)385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDO1-181 Issued: 09-14-O1 Parcel Number: 948-902-806
Job Address: 479 N Street Zoning: RR=H Type: VV=N Occupancy: R-3/U-1
Total Occupant Load:2/2 Nature of Wark: Detached Garase with uastairs ADU
Owner: Bill Matthews /Marian Roh
Contractor: Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REOUHZED:
Electrical -Contact Labor & Industries @ 360-417-2702
RE UIRED INSPECTIONS
APPROVED/DATE
TEMP EROSION & SEDIMENT CONTROL
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS
Setbacks
Footings
lO/3~~d7
/~
Forms ~ I ,
Reinforcement 3 #4 bars
P Piers
E / ,
FOUND ION /
Stem WaU ~~~~~
~`
Forms
Reinforcement Prescriptive
Anchor Bolts w! 2" x 2" x 3/16" washers
Engineered Holdowns highlighted on plans
Waterproofing
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
•;
Permit k BLD01-1 S7
REQUIRED INSPECTIONS APPROVED/DATE
FLOOR FRAMING
Joists
Blocking
Positive Connections
Treated Wood to Concrete
Anchor Bolts w/ 2" x 2"x 3/I6" washers
~. ~
P 2'rd ®z
,
PLUMBING:
Rough-In (D-V-T & Clean outs)
Water Supply
Water Hammer Arrestor at clothes and dishwasher
Gas Supply
/// j~~i7 .
Hose Bibs (backflow protection required) ` ~/l/
Pipe Insulation (minimum R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
Seismic Restraint - 2 places
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
MECHANICAL
LPG Stove -manufacturer's installation instructions shall be
on-site at time of Inspection
Whote House Fan -Bathroom
Kitchen Fan
FRAMING n ~J
Walls Engineered nailing & hold downs highlighted on plans ~`////
>'l~2 t~D ~ f/
"!
Ceilings `7
Roof
Rafter Positive Connection
Blocking
Attic Venting < @ ridge & eave
Windows -escape
Window safety glazing
Windows Ufactor - .40 or better
NFRC window sticker musi be on windows and doors
at inspection time
Air Seal
Fresh Air Intake (Wall Ports)
Fire Blocking
Weather Resistive Barrier
J
LJ
Call 48 hours before you dig for utility line locates
I-800-424-5555
Page 2 of 4
Pemtit d BLIJOLI&I
RFniTiRF.il TNCPF,f Ti(1NC APPROVED/DATE
INSULATION
Floor (R_25)
Walls (R-19
Ceiling (R=30)
Baffles
Vapor Barrier: Backed Batts (walls), PVA Primer (foor &
ceiling
DRY WALL NAILING
Walls
Ceiling
Garage/House Occupancy Separation
FINAL
LPG
House Numbers - 5"
Plumbing
Mechanical/Heating
Insulation Certificate
Smoke Detectors
Weep Screen/Flashing
Vapor Barrier Paint Certificate
Final -Building
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESL) measures shal- be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details).Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Ite-inspection is required after inspection report corrections are completed.
• Ca1148 hours before you dig for utility line locates
I-800-424-5555
Page 3 of 4
-~
PemitR BLD01-181
6. The Building Department is unable to pass final inspection on your projeM until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required. Public Works aooroval must be received urior to
scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
. residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval arior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
•
Ca1148 hours before you dig for utility line locates
I-800-424-5555
Page 4 of 4