HomeMy WebLinkAboutBLD01-171Watemm & KatBBuilditg
181 Quiny Sheer, Suite 307
Pat iownxnd, WA 98368
Phonc: (360j 379.3208 Fex: (360)385-7675
CITY OF PORT TOWNSEND
~ CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO1-171 Issued: 8/08/01 Parcel Number: 989-713-702
Job Address: 640 Adams Street Zoning: RR=II Type: VV=N Occupancy: R-3
Total Occupant Load: 1 Nature of Work: Convert a ara¢e to livin¢ space (¢uest house/studv)
Owner: Bruce & Viva Taaaer Contractor: Mel Coulter
385-4509
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMTI'S REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RE UIRED INSPECTIONS
APPROVED/DATE
DEMOLTTION
Materials from demolition shall be taken to the
Jefferson County Landfrll or other approved off-site
location in accordance with all state and local laws
FLOOR FRAMING !l/G~~~
2" x 4" sleepers
Insulation: R-7.5
Blocking
Positive Connection
Foundation Vents - 4 required
PLUMBING
Rough-In (D -V-T & Clean-outs) ~ ~/~ ~J
~~~LG/ ~~~~
Water Supply /,/
Water Hammer Arrestor @ clothes washer
Pipe Insulation (R-3)
Pressure Reduction Valve if pressure > 80 psi
Water Heater
- strap @ 1/3 points
- pressure relief valve drain to exterior
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
Pe~nital3t.oot-t7tt
REQUIRED INSPECTit7NS APPR(1VFi1tnATF
-
MECHANICAL ----- -_ . ~~.Y.__~
Bath Fan
Environmental Air Exhaust ducting (with backdraft /~
~II
dampers), insulation (R-4) and termination (3' from I
1
openings into building)
FRAMING:
Walls
g
~~l p ~
~
Ceilings ~
Roof
Attic Venting - @ I/I50 if not existing
Windows -escape
Window U-factor - .40 and .44 per analysis
NFRC sticker shall be on windows at time of
Inspection
Air Seal
Door U-factor -exempt
Fireblocking
Weather Resistive Barrier
INSULATION
Floor (R-7.5 in 56 square feet)
Exterior Walls (R-13 & R-20.5 )
g/,(p/(~ r
Ceiling (R-38 )
Baffles
Vapor Bamer -paint
DRY WALL NAILING
Walls ~~~ /~
J
Ceiling f
FINAL
House Numbers -check for 5" numbers
/~/~~/ O 1
Insulation Certificate
Vapor Barrier Paint Certificate
Smoke Detectors
Plumbing
Mechanical
Final -Building
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Permit#BLDOI-171
. 1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within sia months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
CaI148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3