CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11 38 5-22 9 4 for Inspection
Permit Number: BLDOI-167R-1 Issued: 11/26/01 Parcel Number: 948817801
Job Address: 1919 Blaine Street Zoning: RR=II Type: V=N Occupancy: E=2
Total Occupant Load: NC Nature of Work: Revise engineered foundation for classroom portable
Owner: Port Townsend School District #50 Contractor: Monroe Movers
GENERAL CONDITIONS APPLY -SEE LAST PAGE
• SEPARATE PERMITS REOUH2ED:
Electrical -Contact Labor & Industries @ 360-417-2702
REQUIRED INSPECTIONS
APPROVED/DATE
TEMPORARY EROSION & SEDIMENT
CONTROL
See general condition #2
FOOTINGS
Setbacks ~/l~!
Pier Footings /
Reinforcement
5/8" bolts; Simpson VGC82, essential that holes be
cleaned properly
• Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
A ~
Pemtil # BLp01.167R.-(
REQUIRED INSPECTIONS APPRnVF.nl1)ATF.
FLOOR FRAMING (prior to skirting)
6 mil black poly
Anchors -per engineering; ~/. " x 3 "steel straps
Positive Connection: install (2) 3/8"x 2 %s"lag screws to
connect to existing %:"bolts
CMU Blocks -per engineering,• clearance of 18"min. from
lowest point of floor beam% oists and the ground or footing for
min, of 75% of area under home w/ 12"min. elsewhere unless
installation manual specifies; otherwise area around buildings
graded to provide runoff away from portables
FRAMING: -barrier free required
Entry ramps ,n i , ), j f1
Landings 'E" I ~-(' l V
Handrails
FINAL
Fire Department Sign-Off
E-ectrical (I, & I) Sign-Off
Building Numbers -minimum 5" numbers
Barrier Free Access
Final -Building
No holes or gaps greater than %. "allowed in skirting.
Skirting to be rated for contact with earth if bacl f 11 is involved
Crawl space ventilation per installation manual @ I sq.
ft./150 sq. ft.; located close to corners, on at least rivo opposing
sides for cross ventilation. (See next page)
Crawl space access must provide access to old areas under , l
buildings; minimum 18" x 24"unless specked otherwise; ~
CGL
covered with vinyl, pressure-treated wood or metal.
GENERAL CONDITIONS
I. Contractors working on this project are required to have a Labor & Industries contraMor's
registration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construMion; call 385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Soils exposed during construction shall be
temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Permit # BLDOI-167R-1
seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of
adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has been made within six months, or if no inspeMions are
done by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Cal- 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
,..~
Building and Community Development
Waterman & Katz Building
181 Quincy Street Suile 301
Port Townsend, WA 98368
Phone: (360)379-3208 Fax: (36D)385-7675
CITY OF PORT TOWNSEND
•
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Cali 385-2294 for Inspection
Permit Number: BLDOI-167 Issued: 08/16/01 Parcel Number: 948817801
Job Address: 1919 Blaine Street Zoning: RR=II Type: V_N Occupancy: E_2
Total Occupant Load: 49 Nature of Work: Set classroom portable
Owner: Port Townsend School District N50 Contractor: Monroe Movers
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
REOIJIRF.D INSPECTIONS
APPROVED/DATE
TEMPORARY EROSION & SEDIMENT
CONTROL
See general condition #2
FOOTINGS/SLAB (J' J~~~~~ ~~J
'
Setbacks ~ j (~
Pier Footings i
Reinforcement
Stirrup
STHD 14RJ
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
Permit # B[.DOI-16~
RE UIRED INSPECTIONS APPROVED/DATE
FLOOR FRAMING (prior to skirting)
6 mil black poly
Anchors -per engineering
CMU Blocks -per engineer schematic; clearance of IS"min.
from lowest point of f loor beam/joists and the ground or footing
for min. of 75% of area under home w/ ]2 "min. elsewhere
unless installation marmal specifies; otherwise area around
buildings graded to provide runoff away from portables
FRAMING: -barrier free required
Entry ramps
Landings
Handrails
FINAL
Fire Department Sign-Off
Electrical (L & I) Sign-Off
Building Numbers -minimum 5" numbers
Barrier Free Access
Final -Building
No holes or gaps greater than '/r "allowed in skirting.
Skirting to be rated for contact with earth if backfill is involved.
Crawl space ventilation per installation manual @ 1 sq.
ft./150 sq. ft.; located close to corners, on at least two opposing
sides for cross ventilation. (See next page)
Crawl space access must provide access to all areas under
ildin
b
i
l8"
i
24"
l
i
d
h
i
u
gs; m
n
mum
x
un
ess spec
fie
ot
erw
se;
covered with vinyl, pressure-treated wood or metal.
~ //o
GENERAL CONDTTIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
reeistration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 3852294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Soils exposed during construction shall be
temporarily stabilized with mulching, plastic sheeting, etc. Soils-shall be permanently stabilized with
seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of
adjacent properties.
Ca1148 hours before you dig for utility line locates
I-800-424-5555
Page 2 of 3
Permit # BLDOI-167
• 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has been made within siz months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require review and approval prior to making changes in the Feld. Contact the Building
Department 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
i
•