HomeMy WebLinkAboutBLD01-163Wahnnan &. Katz Building
] 81 Quincy S4ee4 Suile 301
Port Toumsend, WA 98368
Pho~w: (3 W) 319-3208 Fax: (3 W) 379-b923
CITY OF PORT TOWNSEND
CONSTRUCTION PERNIIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11 385-22 9 4 for Inspection
Permit Number: I3L~D01-Ifi3 Issued: 8122101 Parcel Number: 972 600 403
Job Address: 1940 31" Street Zoning: R_II Type: VV=N Total Occupant Load: 2
Occupancy: RR=3 Nature of Work: Construct Sinele family residence and detached unheated shed.
Owner: Robert Tyer
(301-9787)
Contractor: Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERIVIITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
Mechanical -Propane Tank and Exterior Piping
RE UIRED INSPECTIONS
APPRO VED/DATE
TEMP EROSION & SEDIMENT CONTROL
`See General Condition No. 2
r Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
GROUNDWORK PLUMBING
Pressure Test
Pipe Joints Exposed
Pipe Bedding
Hydronic Tubing
FOOTINGS
Setbacks
~ ~~~}~~ ~
Footings ~
r
Forms
Reinforcement
Interior Footings
P ier l
OF ~~~'
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Permit N BLDOI-163
REQUIRED INSPECTIONS
APPROVED/DATE
FOUNDATION
Stem Wall
/
Forms ~~3 ~I d f
Reinforcement 1
Anchor Bolts
Vents
Crawl Access
FLOOR FRAMING
Girders
(~ I j l (~ ~
Joists -engineered joist plan on-site at time of inspection I
Blocking
Shield under Posts
Positive Connections
Post-to-Foundation Wa11 Positive Connection
Treated Wood to Concrete
Anchor Bolts and Washers
Radiant Heat Tubing
PLUMBING:
Rough-In (D-V-T & Clean outs)---_.._--~-~
WaterSupply~.__
~,iC, l~uh ~ (l/ /GJo(
Gas Supply
Water Hammer Arrestor @ clothes and dishwasher n~ //
(2.l Z!'
t7l 1 X '
Hose Bibs (backflow protection required) 6
`" 1,
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
Seismic Restraint - 2 places
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
MECHANICAL
Boiler - installation instructions shall be on-site at
j ®/1~~~
time of inspection
Whole House Fan -Half-bath downstairs
Source Specific Fans
Environmental Air Exhaust ducting (w/ backdraR
dampers), insulation (R-4) and terminus (located 3'
from opening)
Ca1148 hours before you dig for utility line locates -
1-800-424-5555
Page 2 of 4
~ Perthit p BLIJOI-163
RF,nT1TRF.n TNSPECTTONS APPROVED/DATE
I'
L
FRAMING: /~
D
Walls ) /
'/
Treated Wood to Concrete ~ Z~ Z I l~ 1
Beams and Headers ! bb
Ceiling
Roof
Rafter
Truss Positive Connection
Roof Venting @ I/I50 - eave & ridge
Windows -escape
Windows -safety glazing
Windows U-factor - .50 or better
NFRC window sticker must be on windows and doors
at inspection time
Air Seal
Fresh Air: window ports
Doors U-factor - .50 or better
Fire Blocking
Weather Resistive Barrier
INSULATION ~ ~ ~1 ~ ~ ~ j y /~~~ ,
`
Floor { R-19) ]
Walls (R_19)
Ceiling (R~30)
Baffles
Vapor Barrier: Plywood with exterior glue for floors;
Face-stapled, backed batts for walls and ceilings
6 mil black poly
DRY WALL NAILING
Walls ~~
//~~,~~.
Ceiling ~
Enclosed usable space under stairs
FINAL
Public Works Sign-Off '~An ~~~ {Z~Z7ft1$ ~7~.
P
House Numbers - 5" minimum
LPG
Stairs/Handrails/Guardrail s
Plumbing
MechanicaUHeating
Insulation Certificate
Smoke Detectors _ n
O
~
OZ
/J,
l J
l
B
ildi
Fi ~
/
/
(
y
'
-
na
u
ng 1
Ca1148 hours before you dig for utility Pine locates
1-800-424-5555
Page 3 of 4
~:
Pem,i[ q BLDOI-163' ;
s
1. Contractors working on this project are required to have a Labor & Industries contractor's re¢istration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5, Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required. Public Works aaoroval must be received prior to
scheduline the Buildin¢Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon- •
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspeMions are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval grior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca11 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4