HomeMy WebLinkAboutBLD01-153
•
_ City of Port Townsend
Watemrm & Katz
181 Quincy Street Suite 301
Port Town+a~d, WA98368
Phone (360) 379-3208 FaY (360) 383-7673
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDO1-153 Issued: 07/17/01 Parcel Number: 948-327-902
Job Address: 312 Hancock Street Zoning: RR=II Type: VV=N Occupancy: RR=3
Total Occupant Load: NC Nature of Work: Construct stairs to new attic storase: remodel bath
Owner: John & Linda Atkins
Contractor: Blue Heron Construction
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF(ITTTRF,n TNSPF.('TinNS
APPROVED/DATE
FOOTINGS
Setbacks - NC
Stair Pier Footings
Forms
Reinforcement
FLOOR FRAMING
joists
Blocking
Shield under Posts
Positive Connection
Treated Wood to Concrete
Anchor Bolts & Washers
PLUMBING: p~~~ ~S ~o~.3ld~
J
Rough-In (D-V-T & Clean Outs)
Water Supply
Hose Bibs (backflow protection. required)
Pipe Insulation - R-3
Pressure Reduction Valve if> 80 psi
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page I of 3
Building Prnnil #BLDOI-153
REQUIRED INSPECTIONS APPROVED/DATE
MECHANICAL
Source Specific Fans
Environmental Air Exhaust ducting (with 1 f
o'
backdraft damper), insulation (R-4) and terminus I
~
l 1
(located 3' from opening)
FRAMING
Walls
Roof -Engineered truss plan designed for storage ~y ,
to be on-site at trine of inspection ~~ ~~
~ Jv(J~6
Attic Venting -ridge & eave
Ceilings
Posts, beams & headers
Windows- egress
Windows -safety glazing (if applicable)
Windows Ufactor - .40 or better for electric heat;
.65 or better for other fuels
NFRC window sticker must be on new
Windows at inspection time
Air Seal
Truss Positive Connection
Fire Blocking
Weather Resistive Barrier
INSULATION
Ceiling (R-38 )
BafTles
Crawl space - 6 mil black poly
DRY WALL NAII,ING
walls ~ Z
t 3`p'
-~
Ceiling f
"
-C
Usable Space under Stairs
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Building Permit #BI.DOI-153
FINAL
House Number - 5"numbers
Plumbing
Mechanical
Insulation Certificate (if applicable)
V. B. Paint Certificate (if applicable)
Smoke Detectors
Final -Building
GENERAL CONDTI'IONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
reeistratian number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of way shall be kept free of dirt
and debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic
sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep
your building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3