Loading...
HomeMy WebLinkAboutBLD01-152Waterman & Katz Building 1 BI Quincy Stteeq Suite 301 Pon Townsend, W A 98368 Phone: (360)379-3208 Pnx: (360)385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLDOl-1S2R-1 Issued: 8/30/01 Parcel Number: 989700611 Job Address: 639 Water Street Zoning: CIII Type: VV=N Occupancy: A-3 Total Occupant Load: 416 Nature of Work: Revision #1: build stockroom at north end of mezzanine: install one-hour doors to mezzanine and main floor stockroom. Square footage of eatin¢/drinkin¢ space is less than 5 000 square feet (4 937 square feet) and mezzanine is less than 1,500 square feet (1385 square feet) so fire sprinkler system is not required by code. Owner: Water Street Coraoration Contractor: Same as Owner 379-6438; 385-5467 GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries C~ 360-417-2702 • See original permit BLDOl-152 for other inspections. RFt'liTiRFiI l'NCPF.C TiC)NS APPROVED/DATE FRAMING -Barrier free door approach clearances required. / q / ~~ Walls Gl/ Ceiling Blocking Positive connections Thresholds - Yz" maximum I -Hour Doors with lever hardware DRYWALL NAILING -One-hour Occupancy / Separation Required. 9 /`/~l Walls Ceiling FINAL Final -Building -See original inspection record. • Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 2 Pemrit tt BLD01-152R-1 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of-way shall be kept Free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections.. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Pu61ic Works requirements have been completed and inspected. For Public Works inspection ca11 3 8 5-2294. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduline the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate. of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval prior to making changes in the £eld. Obtain revisions from the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERNHT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 2 watefman a Katz ewta~ 161 Quivry Street, Sui4301 Port Towreend. WA 98368 Phone: (360)379-3208 Fa:(360)385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDO1-1S2 Issued: 8/09/Ol Parcel Number: 989700611 Job Address: 639 Water Street Zoning: CIII Type: VV=N Occupancy: A-3 Total Occupant Load: 416 Nature of Work: TI• Exuand Maxwell's Restaurant into existine Town Tavern Owner: Water Street Coraoration Contractor: Same as Owner 379-6438; 385-5467 GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Fire Sprinkler System Electrical -Contact Labor & Industries @ 360-417-2702 NOTE: -See also attached Fire Department Memo dated 8/08/01 -HPC Review required prior to making exterior changes in the f eld RE UIRED INSPECTIONS APPROVED/DATE DEMOLITION All materials shall be disposed of in areas off-site meeting the requirements of state and local law FRAMING Walls Ceiling Posts Beams Joists Blocking Positive connections Guardrails Handrails Thresholds Windows: U-factor of .90 or better Air Sea! Draft Stops Ca1148 hours before you dig Tor utility line locates 1-800-424-5555 Page 1 of 3 Pamitk BIDOI-152 a REQUIRED INSPECTIONS APPRnVF,n/DATF. PLUMBING - Bamer--Free Required Drain, Waste & Vent Water Supply Pipe Insulation (R-3) Pressure Reduction Valve if > 80psi Water Heater Pressure Relief Valve Drain to exterior Seismic Straps MECHANICAL LPG Exhaust Fans -ducting (with backdraft dampers), insulation (R-3) and termination (3' from openings into building) DRYWALL NAILING Walls Ceiling FINAL Fire Department Approval Health Department Approval State Electrical Approval Doors -'/2" thresholds and lever hardwaze Guardrail Stairs w/handrail (each side if wider than 44") 100# LL required for. stairs Handrail extensions: 12" @ top, 24" @ bottom Plumbing -Barrier Free Mechanicai Exit Signage Exit Illumination / Final -Barrier Free Design D~~~ Final -Building GENERAL CONDTTIONS 1. CoirtraMors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut dawn while this is accomplished. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 3 Pemtit k BLDOI-152 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11 385-2 294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. S. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval prior to making changes in the field. Obtain revisions from the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3