HomeMy WebLinkAboutBLD01-149watem,an ~ xaz~s~iaug
1 B7 Quinry Sveet, Swte 301
Port Townsen4 WA 98368
Phone: (360)379-3208 Fax: (360)385-7675
CITY OF PORT TOWNSEND
` CONSTRUCTION PERNIIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO~-149R-I Issued: 09/04/01 Parcel Number: 001 021022
Job Address: 952 Walkine Place Zoning: RR=II Type: VV=N Occupancy: U-1
Nature of Work: Construct 888 sg. ft. earaee accessory to sine le-family residence (BLDOI-149).
Owners: Glen and PeQav Stalev
Contractor: Rose. Inc.
(Phil Johnson 385-1570)
GENERAL CONDITIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
APPROVED/DATE
TEMPORARY EROSION & SEDIMENT CONTROL
See Genera[ Condition No 2
FOOTING
Setbacks
Footing
Forms
Reinforcement
LIFER
FOUNDATION
Stem Wall
Forms
Reinforcement
Anchor Bolts with 2"x 2" x 3/16" washers
FRAMING
Engineered truss plan to be on-site at time of inspection
Walls
Treated Wood to Concrete
Anchor Bolts
Ceiling/Roof
Truss Positive Connection
Weather Resistive Barrier
FINAL
Final -Building
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
Pmnit M HLD149R-I
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior
to beginning construMion; ca11385-2294. Measures shall include installation of silt fencing and graveled
construction entrance. Adjacent rights-of--way shall be kept free of dirt & debris. Soils exposed during
construction shall be temporarily stabilized with mulching,plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is
responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy. A Certificate of Occupancy is required for anon-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within ane year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval rior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2
Waterman & Katz BuiWing
181 Quinry Streeq Buile 301
Porl Townsend, WA 98368
Phone 360-379J208 Fax 360J85-7675
•
•
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDOI-149 Issued: 09/04/01 Parcel Number: 001 021 022
Job Address: 952 Walking Place Zoning: RR=II Type: V,=N Occupancy: R-3 (see R-1 for
detached garage)
Total Occupant Load: 9 Nature of Work: Single-family Dwelling (see R-1 for detached
era e
Owner: Glen & Peggv Stalev Contractor: Rose. Inc. ,Phil Johnson
385-1570
GENERAL CONDITIONS APPLY: See last sage
SEPARATE PERMITS REQUHtED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
REQUIRED INSPECTIONS
APPROVED/DATE
TEMP EROSION & SEDIMENT CONTROL
See General Condition #2 & attached Street and
Development Permit
Silt Fencing
Graveled construction entrance required to prevent
dirt and sediment from leaving the site
FOOTINGS
Setbacks
Footings
Forms
Reinforcement
Interior Footings -per engineering
Porch Piers
UFER
CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 4
~_
a
Building Pmn¢ #01.149
REQUIRED INSPECTIONS
FOUNDATION
Stem Wall
Forms
Reinforcement
Anchor Bolts & Washers -per shear wadi schedule
Engineered Holdowns
Vents - ]8 required
Crawl Access
Beam Pockets
FLOOR FRAMING
Girders
Joists -engineered BCI plan on site at inspection time
Hydronic Tubing
Blocking
Positive Connection
Girder to Concrete
Treated Wood to Concrete
Anchor Bolts & Washers -per shear wall schedule
PLUMBING
Rough-In (D-V-T & Clean outs)
Water Supply
Water Hammer Arrestor @ clothes and dishwasher
Gas Supply
Hose Bibbs - backflow protection required
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
Seismic Restraint - 2 places
Pressure Relief Valve drain to exterior, terminate
6" -24" above ground
MECHANICAL
LPG Boiler/water heater
Hydronic in-floor heating
Whole house ventilation
Whole house fan
Window or Wall ports required
Source Specific Exhaust Fans @ bathrooms (SOcfm),
kitchen (l00 cfin) and utility room (50 cfrn)
Environmental air exhaust ducting (with backdraft
dampers), insulation (R-4) and terminus (3' from
openings into building)
APPRnVF.n/i)ATF
.~
•
Call 48 hours before you dig for utility line locates
I-800.424-5555
Page 2 of 4
<,
,, - Building Pmnit #01-149
S ~ RE UIRED INSPECTIONS APPROVED/DATE
C~
i
L J
FRAMING
Walls
Engineered Shear Walls
Ceiling Joists
Roof -engineered truss plan on site @ inspection time
Positive connection
Blocking
Attic venting - eave and ridge vents
Posts, beams and headers -per engineering
Windows -escape
Windows -safety glazing
Window U-factor - .75 or better
NFRC sticker must be on windows at time of inspection
Doors - .40 or better
Air Seal
Fireblocking
Weather Resistive Barrier
INSULATION
Floor (R-19 )
Walls (R-19 )
Ceiling (R-30 )
Baffles
Vapor Barrier -vapor barrier paint
DRYWALL NAILING
Walls
Ceiling
Enclosed Usable Space under Stairs
FINAL
Public Works Sign-off
LPG
House Numbers - S " mrmbers minimum
Plumbing
MechanicaUHeating
Insulation Certificate
Vapor Barrier Paint Certificate
Smoke Detectors
Final -building
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
> ~
".
Building Pe'mil q0l-149 ^t.
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
contractor's reeistration number and a City business lieense. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and
inspected prior to beginning construction; ca11385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-oT way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unabte to pass final inspection on your project until Public
Works requirements have been completed and inspected. For Public Works inspection call
385-2294. A minimum. of twenty-four hours notice is reauired. Public Works approval
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call Tor at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates •
1-800-424-5555
Page 4 of 4