HomeMy WebLinkAboutBLD01-141~D~yHSf+uo P~AA O~ pORT T0~ ~ City of Port Townsend ,~. "~~ a Fire Department " _ ° ~._ ~ `_ , 1310 Lawrence Street, Port Townsend, WA 98368 ~~w (360) 385-2626 Email: ntfd(c~ci Wort-townsend.wa us Fax: (360) 385-1122 INSPECTION MEMORANDUM ~ ~ _ ~~~ To: Suzanne W., Building & Community evelopment Department Fr: Tom Aumock, Assistant Fire Chi Dt: 17 September O1 Re: Piping, Valves, Fittings Inspection; acific Environmental, Inc.-Safeway Fuel Station Ce: Pacific Environmental, Inc. This department made site inspection on this date for the above-referenced proposal at the request of Pacific Environmental, with Don Olin of Pacific Environmental present. Jurisdiction is derived from Section 7902.6 of the Uniform Fire Code, 1997 Edition and this departments "plan review memorandum" dated 20 June 2001: 1. 1. The installation of piping, valves and fittings was found consistent with the requirements of code under Section 7902.6.3 and this department's plan review memorandum item 12.,and; use of compression fittings [pipe-clamp type) for fuel-line piping with knurled pipe ends was noted as consistent with ANSI B31.3 standard for installation, by Pacific Environmental, and therefore is acceptable by code, and; i 2. Piping, valves and fittings were witnessed under pressure-testing for tightness, as was conducted by Pacific Environmental, and to be inspected by independent contractor consistent with manufacturer's standards and Code Section 7902.6.16.2. Copies of said tests are on record with this department, and; It is the administrative determination of this department that the subject piping, valves and fittings are hereby approved to backfilled and covered on site by Pacific Environmental Co. City of Pon Townsend I81 Quincy Street Suite 30] Port Townsend, wA 98365 Phone (360) 379-3208 Faz (360) 385.7675 • CITY OF PORT TOWNSEND BUILDER'S PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLDOl-I4IR-1 Parcel Number: 991403205 Issued: 08/31/01 Job Address: 2611 Sims Wav Zoning: CC=11 Occupancy: SS=3 Nature of Work: Construct fueling island canonv Type of Construction: Canouv: II-N Owner: Satewav Stores, Inc. Contractor: NYD -State Contractor's License and City Business License reuuired GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMI'T'S I2EOUIRED: (see also Hermit #BLDOl-141) ELECTRICAL (WA State Labor and Industries) (360)-417-2702 RE UIRED INSPECTIONS APPROVED/DATE CONTAMINATED SOIL In the event contaminated soil is found, a!! work shall cease. The contractor shall contact the City Building Department and request a site visit by the Building Official. No contaminated soil may be removed prior to the visit by the Building OJjciaJ. In the event, contaminated soil is found, a remediation plan shall be submitted for approval to the Building Official regarding method ojdisposal, stockpiling of contaminant and appropriate clean-tip practices. A!! activities shall be consistent with Cily ordinances and DOE standards for removal and disposal of contaminated soils. TEMPORARY EROSION/SEDIMENT CONTROL Construction dust shall be kept to a minimum to avoid impacts to neighboring properties. If dirt and debris are tracked onto adjacent rights-of--way, contractor shall immediately install sediment control measures that may include installation ofa construction drive-off mat, tine wash and/or sweeping ofpaved surfaces. Refer to approved plan details attached to Street and Utility Development Permit tJSDP01-036. DEMOLITION Materials from demolition shall be disposed ojin areas off=site meeting a!! qualifecations as set forth by state and local law and other government agencies. Ca1148 hours before you dig for utility locates 1-800-424-5555 Page 1 of 3 Budding Permit HBLDOI.141R-1 . REQUIRED INSPECTIONS APPROVED/DATE FOUNDATION Dispenser Islands Guazd Post Details Canopy Footings per engineering, Sheet CS-1; 3000 psi concrete ~ /Z~ ~~ 1 required - no special inspection required per structural engineer Reinforcement -grade 60 per engineering, Sheet CS Vertical Ties Hoop Ties Anchor Bolts per engineering, Sheet CS-2 (4) 1 ''/4" x 24" each base plate per structural engineer PLUMBING -pressure test required for gas lines FRAMING -per engineering -Canopy connection details, Sheets CS-I and CA-1 LIGHTING -metal halide lights prohibited; high- or low-pressure sodium required; 250 watts maximum per fixture - see attached plans and lighting power allowance on Sheet E-I FINAL Final - C-2 design standards compliance; contact John McDonagh @ 379-5085 Final -Fire Department Sign-Off; see memo dated June 20, 2001 Final -Electrical (L & I} Plumbing Final-Banding Ca1148 hours before you dig for utility locates 1-500-424-5555 • Page 2 of 3 Building Pemut #BLDOl-141 R-I GENERAL CONDITIONS i 1. A separate electrical permit is required for any electrical work. 2. Re-inspections are required after any corcections are complete. 3. Final Inspections and approvals are required. 4. All Building Permits expire if no progress has been made within six months or, if no inspections have been made by the Building Department within one year. Call for at least one inspection per year to keep your permit active. 5. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-3208 prior to making changes to the approved plans. 6. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. 7. A final inspection and Certificate of Occupancy is required prior to occupancy. Ca1148 hours before you dig for utility locates t-800-024-5555 Page 3 of 3 Waterman & Kali Building I81 Quvicy Street, Suite 301 Pwl Tolmeend, WA 98368 Phone: (360) 379-3208 Fez: (360) 385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD TffiS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDO1-141 Issued: 7131/01 Parcel Number: 991403205 Job Address: 2611 Sims Wav Zoning: CC=II Type: II-N/V-N Occupancy: S-3; M Total Occupant Load: 90 Nature of Work: Construct 2685 sg ft convenience store (refer to D1-141R-1 for fueling island canouv) Owner: Safeway Stores. Inc. Contractor: TBD -State contractor and Citv business licenses Required GENERAL CONDITIONS APPLY -SEE LAST PAGE ~ ~- - ~ LSS a~~ ~ ~ ~ ~ ~~ta~ zl~~oz SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 Street & Utility Development Permit -Issued 7/27/0] Sign Permit -contact Jean Walat @ 360-385-0644 • NOTE: All welding to be done by WABO certified welders. Credentials shall be presented to the Building Department. RF.f1TTTRFTI TNSPF,C'.TTnNS APPROVED/DATE TEMPORARY EROSION & SEDIMENT CONTROL Temporary erosion and sediment control measures shall be installed on-site per civil plans. b7spection of sill fencing and construction entrance required prior to concrete inspection FOOTINGS ~~~~ ~ ~,1 L~?_ /On- Setbacks Forms ~/ f'~ ~( ~ ~~ ~~ Reinforcement -grade 60 steel ( ~ UFER Yard Light Footings Forms Vertical Steel Horizontal Ties Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 6 Pam@ XBLD01-141 REQUIRED INSPECTIONS APPR(1VF.n/1nATF. SLAB Forms Reinforcement -grade 60 Anchor Bolts - 5/8" ®9' o. c. typical. Engineered Holdowns -per sheet BS2 Floor Drains --- - --- -- ---- PLUMBING: Barrier-Fsee Compiiance Required D-W-V R ~~~vQ481/ll/D h-In (, r ~ ~ we ~Q ~~ 1,~~~ ~ J oug / J Floor Drains -Trap Seal Protection 1 t r 'gr Z~/(~ ro Water Supply ! l "~ Water Hammer Arrestors Hose Bibbs - backflow protection required j t7 ~' Q Grease,Trap Condensate Drains Refrigeration Piping Hot Water Heater Seismic Restraint PTR Valve Drain to exterior MECHANICAL HVAC Units Factory Applied Nameplate Manufacturer's Operating Instructions Attached Unit Identified for Area Served Access and work space for maintenance Disconnect Condensate Drain MOTORS -those not part of tested equipment require NREC compliance NREC Temperature Zones Thermostat Controls Deadband Control Setback with 7 different day types Microprocessor controls with heat indicators Dampers Duct Insulation and Sealing Ca1148 hours before you dig for utility line locates I-800-424-5555 Page 2 of 6 RE UIRED INSPECTIONS APPROVED/DATE Pmnil #BLD01-141 FRAMING All engineered elements require inspection prior to cover Bbl d 2 d S " ° ,. !~ Q/J„ ,~ ~~ ~i~L~ G</urxaa' G>lL an sheets inclu ing B - Refer to B 6 Walls 13 /el ~~~ l ~ Engineered Shear Walls Roof -Engineered truss plan to be on-site at time of Inspection Roof Drains Window Safety Glazing Window U-factor - .90 or better Doors - .60 or better Air Seal Roof Truss/Wall Positive Connection Fire Blocking Draft Stop Weather Resistive Barrier INSULATION Slab -not reguired with trade-off of wall insulation Walls - R-13 required for slab trade-off q /J/J ~a/y~O I (' [/ "1• Roof - R-21 rigid with built-up roof ~~Zs~o/ Vapor Barrier DRYWALL J C QIZ,~~~J7 ~ Walls Ceiling ~D~/Z/0/ SUSPENDED CEILING Frame and supports/Seismic Bracing //~~ /'~/ ' Inspect prior to ceiling file installation "/ / • Ca1148 hours before you dig for utility line locates I-800-424-5555 Page 3 of 6 ~a~~ REnU1RF.n iNSPF.( TinNC APPR(1VFritnATTi Pmeil#eL001-141 LIGHTING - - - -- - - --- - -- - See approved plans and NREC Lighting Summary Daylight zones Exterior Lighting per NREC Exterior Lighting per SEPA/C-II Design Standards - High- or low-sodium lights required; metal halide prohibited - Fixtures @ 250 watts maximum - contact John McDonagh @ 379-5085 for inspection approval PARKING Per Sheet SA 1.3 & SA 2.1 1 Bamer Free, Van Accessible space required LANDSCAPING Per approved sheets SL 1.1- contact John McDonagh @ 379-5085 for inspection DRAINAGE contact the Public Works Departmef¢t @ 385-7212 for inspection FINAL Property address posted -min. 5"numbers Public Works Department Sign-Off Fire Department Sign-Off Health Department Sign-Off Electrical Sign-off (L & I) Barrier Free access Plumbing -Barrier Free Required Mechanical WSVIAQ Certification letter from installer stating compliance with fresh air requirements Restroom wall and floor covering per UBC 807 `~ ~J Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 6 Prneit #aLD01-14I FINAL (continued) Door panic hardware Main exit may have key locking device with sign at exit: "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" with 1" high letters on contrasting background Exit Signage Exit Illumination Final Planning Department - C-II Design Standards compliance required; contact.7ohnMcDonagh @ 379- 5085 for inspection Final -Building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's re¢istration • number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294, press 3. A • Ca1148 hours before you dig for utility line locates I-800-424-5555 Page 5 of 6 Permit MBLDO]-141 ?. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal & approval prior to making changes in the field. Contact the Building Department Q 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 6 of 6