HomeMy WebLinkAboutBLD01-138Waterman & Kets auiWing 161 Quinty Street, Suile 301 Port Townsend, WA 90360 POone: 360J79J208 Fas 360-303-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDO1-138R-4 Issued: 09/27/01 Parcel Number: 948-004-304 Job Address: 3008 Hendricks Street Zoning: RR=II Type: VV=N Occupancy: RR=3 Occupant Load: 411 Nature of Work: Revision #4: Add 120 sg. ft. unheated Four Seasons sunroom. Owner: Scott Marckx & Jeanie Murphv Contractor: Seraphim Builders GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 NOTE: See original permit BLDOl-138 for other inspections. RF(ITTTRFT) TNCPFf TTnNS APPRnVRn/1~ATF, FOOTINGS Setbacks Footings Forms Reinforcement FOUNDATION Stem Wall Forms Reinforcement Anchor Bolts w/ 2" x 2" x 3/16" square washers Vents - I20 =150 = 2 vents located across from each other for cross ventilation required Crawl Access FRAMING Blocking Positive Connections Treated Wood to Concrete Anchor Bolts and Washers Walls -per engineered sunroom details Roof -per engineered sunroom details Safety Glazing Call 48 hours before you dig Tor utility line locates 1-800-424-5555 Page 1 of 2 Building Permit #BLD01.138R-0 KE UIRED INSPECTIONS APPROVED/DATE INSULATION Unheated space FINAL -See also original building permit Final - Sunroom GENERAL CONDTI'IONS I. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of way shall be kept free of dirt and debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted required inspections. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294; a minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections and CertiScate of Occupancy are required PRIOR to occupancy. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval orior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. CaII 48 hours before you dig for utility line locates I-800-424-5555 Page 2 of 2 Waterman & Katz Building 181 Quincy St„ Suite 301 Port Townsend, WA 98368 PFrone (360) 379-3208 Fax: (360) 385-7675 CITY OF PORT TOWNSEND • CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11 385-22 9 4 for Inspection Permit Number: $LDO1-1388-3 Issued: 09/12/01 Parcel Number: 948-004-304 Job Address: 3008 Hendricks Street Zoning: RR=II Type: VV=N Occupancy: R~3 Occupant Load: N/C Nature of Work: Revision #3: add insulation to accessory shoo/studio to meet WATTSUN requirements. Owner: Scott Marckx & Jeanie Murnhv Contractor: Seraphim Builders GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 NOTE: See original permit BLDOl-138 for other inspections. RF.OiJiRED INSPECTIONS APPROVED/DATE FRAMING- See Attached WATTSUN Windows UFactor - .51 Doors UFactor - .42 INSULATION -See Attached WATTSUN Floor (R-30) vented joist @ 16 o.c. Walls (R-21 + R3.6) INT Lap Wood Ceiling (R-49) 324 sq. ft. blown attic ADV FINAL See Original Building Permit GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 2 BLD01-138R-3 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspeMed prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of way shall be kept Tree of dirt and debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294; a minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Builden~ Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 2 Walertnan $ Katz Building 181 Quincy St., Suile 301 Port Townsrnd, W A 98368 Phone (360) 379-3208 Faz: (360) 385.9675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLDOI-138R-2 Issued: 09112101 Parcel Number: 948-004-304 Job Address: 3008 Hendricks Street Zoning: RR=II Type: VV=N Occupancy: R_3 Occupant Load: N1C Nature of Work: Revision #2: add insulation to sinele family residence to meet WATTSUN requirements. Owner: Scott Marckx & Jeanie Muruhv Contractor: Seraphim Builders GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 NOTE: See original permit BLD01-138 for other inspections. REQUIRED INSPECTIONS APPROVED/DATE FRAMING -See Attached WATTSUN Windows UFactor - .40 & .51 Skylights UFactor - .43 or better Doors UFactor - .36 & .41 INSULATION -See Attached WATTSUN Floor (R-30) ventedjoist @ 16 o.c. Walls (R-21) INT Lap Wood Gelling (R-49) 368 sq. ft. blown attic ADV 12 sq. ft. blown attic STD baflled 524 sq. ft. blown scissor 5:12 ADV FINAL See Original Building Permit GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's re¢istration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 2 BLIxI 1-138R-2 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of way shall be kept free of dirt and debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294; a minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Contact the Buildin~ CaI148 hours before you dig for utility line locates I-800-424-5555 Page 2 of 2 t • • Waterman & Kali Bulldi~ IBI Quincy SIree4 Suite 301 Part Towmend. WA 98368 Phone: 3603793208 Fu 360385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLDO1-138R-1 Issued: 07/06/01 Parcel Number: 948-004-304 Job Address: 3008 Hendricks Street Zoning: R_II Type: VV=N Occupancy: RR_3 Occupant Load: 4/1 Nature of Work; Detached studio accessory to SFD (see BLD00-138) Owner: Scott Marcka & Jeanie Murnhv Contractor: Serauhim Builders GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 RFf1TTTRF.TI TNCPFC'TT(lNR APPRnVED/DATE TEMP EROSION & SEDIMENT CONTROL See General Condition #2 Silt Fence as needed Drive Off Mat per attached details FOOTINGS Setbacks Footings Forms Reinforcement Interior Footings UFER FOUNDATION Stem Wall Forms Reinforcement Anchor Bolts w/ 2" x 2" x 3/16" square washers Vents - 4 required Crawl Access Beam Pockets Call 48 hours before you dig Tor utility line locates 1-800-424-5555 Page 1 of 3 Building Permit #BLDOt-138R-t REQUIRED IN~PF,C:Ti(7N~ nppunvF.ntne~r>+ FLOOR FRAMING Engineered BCI plan to be on-site @ time of inspection Girders Joists Blocking Shield under Posts Positive Connection Girder to Concrete Beam Pockets Treated Wood to Concrete Anchor Bolts & Washers Foundation Vents - 4 required PLUMBING: Rough-In (D-V-T & Clean Outs) Water Supply Hose Bibs (backflow protection. required) Pipe Insulation - R-3 Pressure Reduction Valve if> 80 psi FRAMING Walls Roof -Engineered truss plan to be on-site at time of inspection Attic Venting -ridge & eave Ceilings Posts, beams & headers Windows Ufactor - .36 or better NFRC window sticker must be on windows, skylights & doors at inspection time Air Seal Skylights - .58 or better Doors Ufactor-.20 or better Truss Positive Connection .- Fire Blocking Weather Resistive Barrier INSULATION Floor (R-30 ) Wall (R-21 ) Ceiling (R-38 ) Baffles Vapor Barrier: paint Crawl space - 6 mil black poly Ca1148 hours before you dig for utility line locates I-800-424-5555 Page 2 of 3 ~ 1 .~J Building Permit #BI.D01-1388-1 RFf1TTTRF.TI TNCPF.rTTfINC APPROVED/DATE DRY WALL NAILING Walls Ceiling FINAL Plumbing Insulation Certificate V. B. Paint Certificate Smoke Detectors Final -Building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's ret=_istration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of way shall be kept free of dirt and debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294; a minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. 8. All building permits expire if no progress has been made within su months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3 7 • N4terman & Kah BulWlog 161 Qufney Street, Suke 301 Porl Towroend. WA 98368 PAane: 360379-3208 Fax3 60 385-7 67 5 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 Tor Inspection Permit Number: BLDO1-13g Issued: 07/06/01 Parcel Number: 948-004-304 Job Address: 3008 Hendricks Street Zoning: R,_II Type: VV=N Occupancy: RR=3 Occupant Load: 411 Nature of Work: New Single-family Dwelling w/ detached studio BLD00.138R-11 Owner: Scott Marckx & Jeanie Murphv Contractor: Seraphim Builders GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 R F (1T TTR F Il 7NCPF. ('TT(1NC APPRnVF,11/11ATE TEMP EROSION & SEDIMENT CONTROL See General Condition #2 Silt Fence as needed Drive OffMat per attached details FOOTINGS Setbacks / ~ // 3~ Footings t/ (,j~ ~ l " Forms ~ Reinforcement Interior Footings P iers Po ch r , 7 ~ ~rr~ FOUNDATION Stem Wall ~~~ ~~~ Forms Reinforcement Anchor Bolts w/ 2" x 2" x 3/16" squaze washers Vents - 8 required Crawl Access Beam Pockets ABWP) h ld ll l Al t b d /~ Q9"1?'1 ~a~/O~ owns race wa pane ( o terna e (~i(/iC Ca1148 hours before you dig for utility Tine locates 1-800-424-5555 Page I of 4 Building Pemtit NBLD01-138 REQUIRED INSPECTIONS APPROVED/DATE FLOOR FRAMING Engineered BCI plan to be on-site @ time of inspection Girders '~~~ Joists Blocking Shield under Posts Positive Connection Girder to Concrete Beam Pockets Treated Wood to Concrete Anchor Bolts & Washers Foundation Vents - 8 required , PLUMBING: Rough-In (b-V-T & Clean Outs) Water Supply Water Hammer Arrestor @ clothes & dishwasher Hose Bibs (backflow protection. required) Pipe Insulation - R-3 Pressure Reduction Valve if> 80 psi Water Heater Seismic Restraint - 2 places Pressure relief valve drain to exterior, terminate 6" - 24" above ground MECHANICAL Whole House Ventilation Source Specific Fans Environmental Air Exhaust ducting (with backdraft damper), insulation (R-4) and terminus (located 3' from opening) ~. Call 48 hours before you dig for utility line locates • I-800-424-5555 Page 2 of 4 Building Permit tlBLD01-138 • RE UIRED INSPECTIONS APPROVED/DATE FRAMING Walls Alternate Braced Wall Panels ~jfZ fC~~ Roof -Engineered truss plan to be on-site at 7 time of inspection Attic Venting -ridge & eave Ceilings Posts, beams & headers Windows -egress Windows -safety glazing Windows Ufactor - .36 or better NFRC window sticker must be on windows, skylights & doors at inspection time Air Seat Skylights - .58 or better Doors Ufactor - .20 or better Truss Positive Connection Fire Blocking Weather Resistive Barrier INSULATION (~ ~, Floor (R-30) j~/ Wall (R-21 ) Ceiling (R-38 ) Baffles Vapor Barrier: paint Crawl space - 6 mil black poly DRY WALL NAILING n ,J] y Walls // ~ G G Ceiling FINAL Public Works Sign-Off ]~ z /~QZ House Number - 5 "numbers Plumbing Mechanical Insulation Certificate V. B. Paint Certificate Smoke Detectors Final -Building Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 Building Permit #BI,D01.138 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's reu_istration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of way shall be kept free of dirt and debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall .review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294; a minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. • 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval urior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig for utility line locates I-800-424-5555 Page 4 of 4