HomeMy WebLinkAboutBLD01-122City of Port Townsend
Waterman & Katz Building
18I Quincy Street, PortTownsrnd, WA9ti368
(360) 379-3208 Fax (360) 385.7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERNIIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BI.D~I-122
Job Address: 4509 Louez Avenue
Total Occupant Load: add 1
Owner: Gerald and Gail Danner
Issued: 06/18/01 Parcel Number: 992300036
Zoning: R_II Type: VV=N Occupancy: RR=3
Nature of Work: Residential Addition
Contractor: Little & Little Construction
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REOUHtED:
Electrical -Contact Labor & Industries @ 360-417-2702
REOiJiRED INSPECTIONS
APPROVED/DATE
EROSION CONTROL
Sweeping of paved surfaces may be required to
eliminate the tracking of dirt and debris onto City
rights-of--way
FOOTINGS
Setbacks 7~~~~dl
Footings
Forms
Reinforcement
Interior Footings
UFER
FOUNDATION
Stem Walt
~~~
Forms (/
(JZ
Cll "~
Reinforcement
Anchor Bolts
Vents - 5 required
Crawl Access
Call 48 hours before you dig for utility line locates
I-800-424-5555
Page 1 of 4
Building Pcrntit NBLDOI-l22
REQUIRED INSPECTIONS APPRnVF.n/nATF.
FLOOR FRAMING
BCI joist plan shall be on-site at time of Inspection -
7oists
Blocking _
(%f 1 ~ ~ l
Shield under Posts I
Positive Connection Post-to-Beam
Positive Connection Post-to-Foundation Wall
Treated Wood to Concrete
Girder to Concrete
Anchor Bolts & Washers
ING ----
--_
Rough-In (D-V-T & Clean Outs) ~
ater Supply ~~
~,
~ ~~ d ~
a er ammer Arrestor @ Dishwasher -- --
Pipe Insulation (R-3) '
Pressure Reduction Valve if> 80 psi
MECHANICAL
Kitchen Fan
Environmental Air Exhaust ducting (with backdraft
damper), insulation (R-4) and terminus (located 3'
from openings)
FRAMING:
Walls
Attic Venting -ridge & soffrt
Ceilings a lL
Roof
d
d ~'~
Posts, Beams an
Hea
ers
Windows Ufactor - .53 or better per WATTSUN r ~ Cf'p,
NFRC window sticker must be on windows & << j
skylights at inspection time
S li hts - .44 or better
~~ C
Air Seal ~ 1[ , ~
Fres r. window or wa port require ~ ~ ~-~ '~
Door a - .
Rafter Positive Connection
Fire Blocking 0 • ~~~ - l ~ b ~
r
Weather Resistive Barrier G l ~
J
~o~
•
Ca1148 hours before you dig Tor utility line locates
1-800-424-5555
Page 3 of 4
Building Permit #BLIHII-122
•
RF,OiIIRED INSPECTIONS
APPROVED/DATE
INSULATION ~
f~~
Wall (R-19) ~
~
~
L ~~
r
Floor (R-30)
Ceiling (R-30 )
Baffles
Vapor Barrier: paint
6 mil black poly in crawl space
DRY WALL NAILING
Walls
~J, ~~
Ceiling
~~ G
~ ~~` ~
FINAL
House Numbers -check for 5" numbers
Plumbing
Mechanical
V.B. Paint Certificate
Smoke Detectors throughout existing construction: one in
each sleeping roam and in each area/halhvay leading to
sleeping rooms with a minimum of one on each floor ~ ~/ ~
3 ~ ~ _ n
(
/
'l)//l
Final -.Building v
J
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
reeistration number and a City business license. Failure to provide proof of this documentation
prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; call 385-2294, press 3. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details). Adjacent
rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be
temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized
with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for
protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall
panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
Call 48 hours before you dig for utility line locates
I-800-424-5555
Page 4 of 4
/az
Building Pemtit #BLA01-122
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294,
press 3. A minimum of twenty-four hours notice is required. Public Works aoaroval must be
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a
non-residential projeM.
8. All building permits ezpire if no progress has been made within siz months, or if na inspections
are done by the Building Department within one year. Call for at least one inspection per year
to keep your building permit active.
9. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Cali 48 hours before you dig for utility tine Locates
I-800.424-5555
Page 5 of 4