Loading...
HomeMy WebLinkAboutBLD01-103Waterman & Katz Building 181 Quincy Street Suite 301 Port Townsend, WA 98368 Phone (360) 379-3208 Fax (360) 385-7675 CITY OF PORT TOWNSEND PERMIT AND INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2626 for Inspection Permit Number BLD01-103 Issued 5/21/01 Parcel Number: 101351001 Job Address Building 502 Harbor Defense Way Zoning P/OS Occupancy E-2/A-3 Nature of Work Install Fire Alarm System Use of Building Marine Science Center (This is the Marine Science Center building on land, not over the water./ owner Washington State Parks Contractor Federal Fire Safety, Inc. ~ * * * Cun ntt~nhnA F:rn nnn~rfmcnt mourn irafcr! ~/1!i/n 1 * *' ~ ~ Site Inspection Inspector Date System Tests Inspector Date Contractor's Material & Test Certificate Inspector Date As-Built Plans filed with Owner & Plan Box Inspector na, FACP (24 x 36 maximum format) Date Inspector Date Fire Department Final Inspection Approval Inspector Date \1Citypdc\shappslTtipslPermits\Ol PERMrfS\O1-103alarm.doc Pemtit ~ ELD01-103 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Owner or owner's agent shag review and oversee correction of any and all deficiencies noted by required inspections. 3. Re-inspection is required after inspection report corrections are completed. 4. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. A minimum of twenty-four hours notice is required Public Works approval must be received Drior t0 scheduling the BuUlding Department's final inspection. 5. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 6. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 7. Revisions require submittal & approval prior to making changes in the field. ContaM the Building Department (g~ 379-3208 prior to making changes to the approved plans. S. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. • 1\Citypdc\shapps\Trips\Permita\01 PERMITS\01-103alatm.dce • '' < pOPT TO ~p~NeatW PIRP City of Port Townsend ;op ~,~ g ~ ~ ~ Fire Department ~ o .,: ' ~~¢ Fire Protection Svstem Inspection Checklist: Automatic Fire Alarm Svstem General Alarm System Permit No.: BuildingPermitNo.: BLnO/-/~~ Facility Address: Bc.d OL .~ GVO-c~Qr-,/ Facility Name: ~l92 ~-Q--~" Svstem: M nual Automatic ^ Voice O Monitored ? ^ Graphic ^ Stand Alone Elements: Heat ^ Rate of Rise ^ Smoke ^ Horn C~Horn/Strobe ^ Strobe ^ Coiling Door /. C3'Manual Pulls ^ Egress Control Contractor's State License [&NICET]: chc ,~y(C Inspector Int. & Dt • U~ 2%Vl Plan Review Inspector Int. & DtC/~ Cil' Plans Received [date: ~G ~ ] G1 Mfr. Specifications of individual elements ® Floor Plan(s) complete Ca, Battery Calculations, wring types and sizes. Power connection, Emergency Power Source . Site Insaection Inspector Int. & D f o~ ,c~ ~ System installationllocation check-off p~ Panel Location ^ Remote Annunciation l3 Access Keys 1~ Labeling ~ Operating Instructions. ^ Tools Svstem Test(s) / Lnspector Int. & Dt.:'f+ ~ 7 3S•Q( ~ Heat ^ Rate of Rise ^ Smoke ^ Horn H Horn/Strobe ^ Egress Control Fa'R4anual Pull-station ^ Strobe ^ Monitoring Agency Test _ ^/////Emergency Power Source ^ Fire Alarm System Inter-tie with Sprinkler System Test (Tamper): ~5ecs. Contractor's Material & Test Certificate: Inspector Int. & Dk: ~~.264~ As-Built PlansAnstructions in Plan Box (u) FACP: Inspector Int. & Dt.: Monitorine Aeencv Name: TBD Address: Contact Number: Account Number: Panel Reset Code . Code Number: n:.+ ~ +n6 '>pF Fire Deaartment Aoaroval Inspector: f) ~'mOCtc '73'Y1~7 Date: G~--yam-~1 . Filed wBldg. Official: b~' 2/~' d f C:\TOm's File Cabinet\Forms & Templates\Fre Alarm Sysrem\Fire Alarm System Inspection Checklist.doc 7/25/01