HomeMy WebLinkAboutBLD01-101
•
u
City of Pon Townsend
Waterman & Kau Building
181 Quinry Street, PmiTownsend, WA 98368
(360) 379-3208 Faz (360) 385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD~I-IQI Issued: 06/11/01 Parce! Number: 984904701
Job Address: 419 O Street Zoning: RR=II Type: VV=N Occupancy: RR=3
Total Occupant Load: add 1 Nature of Work: Residential Addition
Owner: Richard & Marv Sealer Contractor: Little & Little Construction
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF,nTTiRF.D INSPECTIONS
APPROVED/DATE
EROSION CONTROL
Installation of graveled drive-off mat and sweeping
of paved surfaces may be required to eliminate the
tracking of dirt and debris onto City rights-of--way
FOOTINGS
Setbacks
Footings
Forms
Reinforcement
Porch Piers
LIFER
FOUNDATION /
Stem Wall ,~,q~,~
i~"`i'~(J ~~~/
Forms
Reinforcement
Anchor Bolts -'h" x 10" @ 42" o.c. and 5/8" x 10"
@ 24" o.c.
Vents
Crawl Access
Engineered Holdowns
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
Building Permit #BLDOI-10!
REQUIRED INSPECTIONS APPROVED/DATE
FLOOR FRAMING
BCI joist plan shall be on-site at time of inspection /'
Joists ~~~/ ~ / 1 1 /
Blocking ( lJ~
Hangers
Positive Connection
Treated Wood to Concrete
Anchor Bolts & Washers -per engineering; see above
PLUMBING
Rough-In (D-V-T & Clean Outs) ~~ ~ / ~ /~ n
/ [v'~~
Water Supply (
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
MECHANICAL
Source Specific Fan ~/~ Q~~
Environmental Air Exhaust ducting (with backdraft /
damper), insulation (R-4) and terminus (located 3' l
from openings)
FRAMING:
.Walls
Engineered Shear Walls
7~L 3 / O 1
Attic Venting -ridge & eave
Ceilings
Roof
Posts, Beams and Headers
Windows Ufactor - .37/.50 or better per WATTSUN
NFRC window sticker must be on windows &
skylights at inspection time
Skylights - .43 or better
Air Seal
Door UFactor - .33 or better
RaRer Positive Connection
Fire Blocking
Weather Resistive Barrier
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
r
RE UIRED INSPECTIONS
•
Building Permit #BLD01-101
APPROVED/DATE
SULA
Wall(R-21) ~~' ~~
Floor (R-19/R-30) ~~
Q ~
T'
J,
Ceiling (R-38) a-
~
~ '
attles ~%
Vapor Barrier. paint
6 mil black poly in crawl space
DRY WALL NAILING r
'
Walls ~/l,~/ l~
/~.
Ceiling ,/ - ,
Enclosed Usable Space under Stairs (if applicable)
FINAL
House Numbers -check for 5" numbers
~0/~ ~O~D ~
Plumbing
Mechanical
V. B. Paint Certificate
Smoke Detectors throughout existing construction
Final -Building
GENERAL CONDITIONS
I. Contractors working on this project are required to have a Labor & Industries contractor's
reeistration number and a City business license. Failure to provide proof of this documentation
prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; ca11385-2294, press 3. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details). Adjacent
rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be
temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized
with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for
protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall
panels (ABWP) require inspection prior to cover.
4. .Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
• Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
.1
Building Perniit #BLDO1-301
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294,
press 3. A minimum of twenty-four hours notice is required. Public Works approval must be •
rwrw:vwd nrinr fn crhwdnlina fhw Rnild:no ilwnarfmwnf~c final :nenwr}:nn
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a
non-residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections
are done by the Building Department within one year. Call for at least one inspection per year
to keep your building permit active.
9. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Call 48 hours before you dig for utility line locates •
I-800-424-5555
Page 1 of 4