HomeMy WebLinkAboutBLD01-089wai~~~ a xm~B~ma~ ~s~ Qu~~q so-ca, sww w~ Pwt 7owmrnd, WA98368 PAone: (360)3793208 Fsc (360)3857675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD I THIS CARD MUST BE POSTED AT CONSTRUCTION STI'E Call 385-2294 for Inspection Permit Number: BLDO1-OS9 Issued: 04/30/01 Parcel Number: 948306705 Job Address: 1805 Gise Street Zoning: RR=II Type: VV=N Occupancy: R_3 Nature of Work: SFR Interior Remodel: Add Attic Storage Loft & Reroof Existing House Owner: Richard and Joan Nelson Contractor: Owner GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 REQUIRED INSPECTIONS APPROVED/DATE FRAMING ~ / ~~ F)" ' . Walls Ceiling Air Seal Fire Blocking Attic Access & Weather Stripping INSULATION ~-j',. ; ~ ~ . ' ~ Walls: R-19 <~" ° ~ `~ ~ Ceiling: R-30 Vapor Barrier Req'd: 4 mil poly, vapor barrier paint, etc. DRYWALL/NAILING (as applicable) ~~~~'.~;~ ?X:- Walls Ceilings FINAL House Numbers -check for 5" numbers Final -Roof & Ridge Vent Insulation Certificate (if applicable) Vapor Barrier Paint Certificate (if applicable) Smoke Detectors in existing construction per '97 UBC Final -Building Call 48 hours before you dig for utility line locates 1-800-424-5555 Page I of 2 Permit gaI.IJOI-089 1. ContraMors working on this projeM are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc, once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass. final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A 7. Final Inspections are required prior to occupancy; a Certificate of Occupancy is required for anon-~ residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year.. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal & approval prior to making changes in the field. Contact the Building Department @ 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 2