Permit Number: BLDOI-OH4R-2 Issued: 08/02/01 Parcel Number: 985201002
Job Address: 2029 Saruce Street
Total Occupant Load: 2
Zoning R-II Type: V-N Occupancy: F-1
Nature of Work: Rev. #2: Add shower to accessible bathroom: relocate door and window
Owners: Christopher English and Jean Tarascio
Contractor: Dick Shiaman/Olympic Steel
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REOUHiED:
Electrical -Contact Labor & Industries @ 360-417-2702
See Original Permits BLDOI-084 and R-1 for other inspections
REQUIRED INSPECTIONS
APPROVED/DATE
PLUMBING -barrier free required r'
~
~
~~~
Shower -per attached details ~
`~~
FRAMING
See permit #BLD00-089
Call 48 hours before you dig for utility line locates
I-800-424-5555
Page 1 of 2
PemtitNBI.D01-1~ a
GENERAL CONDIITONS
1. Contractors working on this project are required to have a Labor & Industries contractor's re¢istration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspeMed prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-oi way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 3852294. A
minimum of twenty-four hours notice is repaired. Public Works approval must be received prior to
scheduline the Buildine Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-~
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2
,r
Waterman & Ketz Building
181 Qumry S Vee1 Suite 301
Pat Toumvvid, WA 98368
Phone: (360) 37¢3208 Fax: (360) 385-0675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO1-084R-1 Issued: 06/01/Ol Parcel Number: 985201002
Job Address: 2029 Suruce Street Zoning R-II Type: V-N Occupancy: F-1
Total Occupant Load: 2
Nature of Work: Rev #1• Revised concrete streneth of 2500 psi. No special inspection required.
Owners: Christopher Enelish and Jean Tarascio
Contractor: Dick Shipman/Olvmpic Steel
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
• See Original Permit BLDO1-084 for other inspections.
RF.OTITRF,D INSPECTIONS
APPROVED/DATE
FOOTINGS:
See attached revised Page S-1; special inspection
not required for 2500 psi concrete.
SLAB FOUNDATION:
See attached revised Page S-1; special inspection ~~~ r-~ /~9
~ J ~ (~"
not required for 2500 psi concrete.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page I of 2
..
Pemvlk BLDO7-084 !.
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's re¢istration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
Z. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deTiciencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
schedulin¢ the Buildine Department's final inspection.
7. Final InspeMions are required prior to occupancy; A Certificate of Occupancy is required for anon-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (3'743208) prior to making changes to the approved plans.
] 0. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
I-800-424-5555
Page 2 of 2
Walan~m R KatzBwlding
1 el Quincy Street, Suite 3DI
Pal Townsend, WA 98368
Phone: (360) 379-3208 Fsz: (360) 365-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MU5T BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDOI-0$4 Issued: 5/15101 Parcel Number: 985201002
Job Address: 2029 Spruce Street Zoning: RII Type: VV=N Occupancy: F-1
Nature of Work: Construct New 576 sg. ft. Metal Stud Building Occupant Load: 2
Owner: Christopher English/Jean Tarascio Contractor: Dick Shipman/Olympic Steel
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor and Industries @ 360-417-2702
NOTE: Special Inspection required for foundation concrete where structural design is based on greater
than 2500 psi, 3, 000 psi (footings) acrd 4, 000 psi (slab and turn-dawn) this permit, per UBC Section
1701.5 Item I. Special Inspector shall be ICBO certified and listed in the current edition of WABO
A enc and Ins ector Re islet or present credentials to the Building Department prior to performing
inspections. Required Special Inspection Reports shall indicate compliance with the plans and
. specifications and shall be copied to the Building Department in a timely manner. Permit Holder or
Permit Holder's Agent shall review and oversee correction of any and all deficiencies noted by required
special inspections.
RE UIRED INSPECTIONS APPROVED/DATE
TEMP EROSION & SDM'T CONTROL
Erosion control measures to be installed as needed during
construction
FOOTINGS ,n /
~~}
Setbacks -per UBC /
l/~w/
7~
20' for exterior walls or 1-hour construction /
/
openings protected < 10 feet
openings prohibited < 5 feet
Footings
Forms
Reinforcement
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Petetit A BLI701 ~`~.;_
RE UIRED INSPECTIONS APPROVED/DATE
SLAB FOUNDATION
Forms
Reinforcement
Simpson Wedge Anchors
Slab/Radiant
- R-10 under slab
- R-10 @ perimeter
UFER
PLUMBING -Barrier Free Design Required ~
Rough-In (D-W-V & Clean OutsO ~~~~/
p(,~ ~(~ `~~3/f~
Water Supply `
LPG Supply
Pipe Insulation (R-3)
Pressure Reduction Valve if pressure > 80 psi
Hydronic Tubing ,
~1 ~ ~ Z
MECHANICAL '
Boiler/Water Heater -manufacturer's installation
instructions shall be on-site at time of
inspection
Fresh Air -compliance with I/20 of floor
area in openings
Source Specific Fan @ Bathroom -terminus 3'
from building openings
NREC Temperature Zones
Thermostat Controls perNREC 1412.1
FRAMING -All welding to be done by certified
welders
~ ~/13/~/
Walls I/ t
Roof
Positive Connections -per engineered details
Columns
Fireblocking @ 10' o.c. horizontal and vertical
Air Seal
Windows U-factor - .90 or better
NFRC window sticker must be on windows at inspection
time
Doors U-factor - .60 or better
INSULATION / /
Walls-R-11 ~/ ~G07/
Roof- R-11 GGG
Vapor Barrier Required
Call 48 hours before you dig for utility line locates
I-800-424-5555
Page 2 of 4
.J
•
i
RF.fITTTRF.TI TNRPF.("i'TnNS
Permit q BLiNH-084
APPROVED/DATE
DRYWALL/NAILING
Walls
I-Hr. F. R. Walls
Ceiling
3DZ
LIGHTING
Lighting Budget -prescriptive option
Daylight Zones
FINAL
Property Address Posted
L~6 t"'U'~8 f~p~ r t~i~'L ~O/~~d
Fire Department Approval -see attached memo dated
5/02/01
Electrical Approval (L & I)
Insulation Certificate (if applicable)
Vapor Barrier Paint Certificate (if applicable)
Barrier Free Access & Design
Final -Plumbing
Final -Mechanical
Building ~ ~'~ 0~
• GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294, press 3. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting,
etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is
complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
,~
Call 48 hours before you dig for utility line locates
I-800-424-5555
Page 3 of 4
Permit#BLD01-084 -.,`,
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspeMed. For Public Works inspection call 385-2294, press 3. A
minimum of twenty-four hours notice is required. Public Works aooroval must be received arior to
scheduline the Buildine Department's final inspection.
7. Final Inspections are required prior to occupancy; a Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Obtain revisions from the
Building Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4