HomeMy WebLinkAboutBLD01-064W atem~an and Katz Building
181 Quincy Street Suile 301
Porl Townsend, WA 98368
Phone (360) 379-3208 Fax (360) 385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERNIIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO1-O64 Issued: 4/12/01 Parcel Number: 965-700-801
Job Address: 1011 Cass Street Zoning: R_II Type: VV=N
Occupancy: RR=3 Total Occupant Load: N/C
Nature of Work: Add upstairs bathroom, and skylight.
Owner: Judith Livingston Contractor: Same as Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF,OTTTRF,n TNSPF.CTTONS
C,
J
APPROVED/DATE
PLUMBING
Rough-In (drains, vents, traps and clean outs)
Water Supply
Pipe Insulation (R-3)
Pressure Reduction Valve in > 80 psi
MECHANICAL
Bathroom Fan
Environmental Air Exhaust ducting (w/ backdraft
damper), insulation (R-4) and terminus (located 3'
from openings)
FRAMING
Walls
Door Threshold
Fire Blocking
Skylight -minimum .58 or better U-factor for
electric heat; .68 or better for other fuels
INSULATION
Fill exposed exterior wall cavities
• Call 48 hours before you dig for utility line locates
1-800-424-5555
Page I of 2
Building Permit #BLD01-064
RF.nIJiRED iNSPF.CTinNS APPRnVF11/nATF.
DRYWALL NAILING
Walls
Ceiling
FINAL
House Numbers -check for 5 "numbers
Smoke Detectors throughout
Final -Plumbing
Final -Mechanical
Final -Building
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contraMOr's
registration number and a City business license. Fai-ure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Adjacent rights-of way shall be kept free of dirt and debris. Any soils eaposed during construMion shall
be temporarily stabilized with mulching, plastic sheeting, etc. Soila shall be permanently stabilized with
seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of
adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspeMion on your project until Public Works
requirements have been completed and inspected For Public Works inspection ca11385-2294; a
minimum of twenTy-Tour hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has been made within sia months, or if no inspections are
done by the Building Department within one year. Call for at least one inspeMion per year to keep
your building permit active.
9. Revisions require review and approval urior to making changes in the field. Contact the Building
Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
CaI148 hours before you dig for utility line locates •
1-800-424-5555
Page 2 of 2