HomeMy WebLinkAboutBLD01-057wstermm ~ xztz auitaing
I81 Quinry Sheet, Suite 301
Pat Toamsend WA 98368
Phone: (360) 379-3206 Faz: (360) 386-7676
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO1-OS7R-1 Issued: 06/07/01 Parcel Number: 985203609
Job Address: 1151 V Street Zoning: R-II Type: V-N Occupancy: R-3/U-1
Total Occupant Load: 712
Nature of Work: Rev #1 • Revised enpineerina reQardinE floor foists, stairway column, and shear wall #1 and
4 near office and dinin¢ room. See attached letter dated Mav 24.
Owner: LBR Construction dba Anderson Homes, LLC Contractor: LBR Construction
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REOUIItED:
.Electrical -Contact Labor & Industries @ 360-417-2702
See also Original Permit BLDOl-057 for required inspections.
RF.OiIiRF.D INSPECTIONS
APPROVED/DATE
FOOTING:
Ribbon footing
FOUNDATION:
Engineered holdowns per item #d
FRAMING:
1
6 x 8 column and straps per item #b ~~" ~~®
Shear wall #1 per item #c
Shear wall #4 per item #d
Pony wall per item #d
Call 48 hours before you dig for utility -ine locates
1-800-424-5555
Page 1 of 2
PamiLNBLD01-05771-1
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11 38 5-2 2 94. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. Far Public Works inspection ca11385-2294. A
scheduline the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-
residential project.
8. All building permits expire if no progress has been made within siz months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2
. c P r.
Waterman & Kab Building
181 Quincy Sheet, Suile 301
Port TownsenQ WA 98368
Phone: 360479-5086 Fna 360385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 Tor Inspection
Permit Number: BLDO1-OS7 Issued: OS/04/Ol Parcel Number: 985203609
Job Address: 1151 V Street Zoning: R_II Type: VV=N Occupancy: R-3/U-1
Total Occupant Load: 7/2 Nature of Work: Construct Single-family Dwellin¢ with earaee
Owner: LBR Construction dba Anderson Homes. LLC Contractor: LBR Construction
GENERAL CONDITIONS APPLY: See last Wage
i
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
N TF: All engineered details including holdowns, shear walls & connections
require inspection prior to cover
RFnTiTRF>) TNSPFCTTnNS
APPRnVF,n/DATE
TEMP EROSION & SEDIMENT CONTROL
See General Condition #2
Graveled construction entrance required to prevent '
dirt and sediment from leaving the site
FOOTINGS
Setbacks / ,~ /
~/ /~j/~~
Footings (((
Forms
Reinforcement
Interior Footings
Po eck Piers
~~~
CALL 48 hours before you dig for Utility line locates
1-800-424-5555
Page 1 of 5
Building Pemtit #O1-051
RE UIRED INSPECTIONS
APPROVED/DATE
a 1 T .. 'n
FOUNDATION
Stem Wall
Forms
Reinforcement
Anchor Bolts & Washers -per engineering
Foundation Vents -12 required
Crawl Access
Post-to-Fdn, Wall Positive Connections
Engineered Holdowns
~'/Z~ ~Q,
FLOOR FRAMING
NOTE: Engineered BCII joist plan on-site and
available to the Inspector at inspection time //2 , /~O~ n n
V `f`/ `(~j
/
Girders ~
-
Joists
Blocking
Shield under Post
Positive Connection
Girder to Concrete
Treated Wood to Concrete
Anchor Bolts & Washers
Rough-In (D=V-T &'Clean outs)
Water Su
l
C~ ~ ~~ ,,~~77 ~~'' G
''
~
pp
y 6L~D
~
~ (v , ~
Gas Sup
ater Hammer Arrest r
Hose Bi - ow protection require
Pipe Insulation (R-3) ok ~ G
~
Pressure Reduction Valve if> 80 psi ~ 1 ~' ~ °~
Water Heater
Seismic Restraint - 2 places
Pressure Relief Valve drain to exterior, terminate
6" -24" above ground
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 5
•
Building Permit ilOlA57
REQUIRED INSPECTIONS APPROVED/DATE
MECHANICAL
LPG Fireplace ~~
G (//'~ ;/~
~
Heat Pump - HSPF =h 6.8; COP =h 3.0 t
Ducts & duct insulation (supply and return air ducts
R-8; supply ducts in conditioned space R-4)
Whole house ventilation
Integrated system
7" minimum smooth duct (8" min. flex)
Automatic (electric) damper -certification from
installer required at final
Source Specific Exhaust Fans @ bathrooms (SOcfin),
kitchen (100 cfrn) and utility room (50 cfm)
Environmental air exhaust ducting (with backdraft
dampers), insulation (R-4) and terminus (3' from
openings into building)
.FRAMING -Street Development Permit to be issued
prior to Framing ~
u ~ ~~~ ~ /~
Walls / ,/
Engineered Shear Walls -block all panel edges
Roof -engineered truss plan to be o~:-site at time of
Inspection
Truss positive connection
Attic venting -ridge & eave
Posts, beams and headers
Windows -escape
Windows -safety glazing
Window U-factor - .65 or better
NFRC sticker must be on windows, skylights & doors at
time of inspection
Air Seal
Fireblocking
Weather Resistive Barrier
INSULATION
Floor (R-19 required)
(,(~~ ~3~D
Walls (R-19 including garage/house common wall)
Ceiling (R-30)
Baflles
Vapor Barrier - 4 mil poly on walls
6 mil black poly in crawl space -seams lapped 12"
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 5
Building Pemtit #01-057
REQUIRED INSPECTIONS APPROVF.D/l)ATF.
~. . .
DRYWALL NAILING
Wails //~~ n
Cj //ll~l ! Il/
Ceiling (1 I~':IY
Garagell ouse Occupancy Separation
Enclosed Usable Space under Stairs
FINAL
Public Works Sign-off
House Numbers - 5" numbers.
Plumbing
Mechanical/Heating
Fresh air certifrcation from installer
Insulation Certificate
Smoke Detectors
Final -building
L / o
GENERAL CONDITIONS
r
1. Contractors working on this project are required to have a Labor & Industries contractor's.
registration number and a City business license. Failure to provide proof of this documentation •
prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing
and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free
of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching,
plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc.
once construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced. wall
panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspeMion is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspeMion call 385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior
to scheduling the Buildine Department's final inspection.
Ca1148 hours before you dig for utility line locates
I-800.424-5555
Page 4 of 5
Building Permit #01-057
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a
non-residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections
are done by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
9. Revisions require review and approval riot to making changes in the field. Contact the Building
Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 5 of 5
n
U