HomeMy WebLinkAboutBLD01-053` Watermnn & Kalz Building
181 Quinq Slree4 Suite 301
Port Townsend, WA 98368
Phone: 360S79J208 Fax 360J85-7675
CITY OF PORT TOWNSEND
n
~J
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO1-OS3 Issued: 415101 Parcel Number: 999100032
Job Address: 2058 Victoria Avenue Zoning: R_II Type: VV=N Occupancy: RR=3
Total Occupant Load: 8 Nature of Work: Set New Manufactured Home
Owner: Scott Riegs Contractor: Vallev Proaerties & Construction WAINS#1690
****Installer: See Attached Installer Tag****
L
~J
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REOUIlZED:
Electrical -Contact Labor & Industries @ 360-417-2702
NOTE: Set-up manual shall be on-site at time of inspection.
RF.f)TTiRF.TI iNCPF.('TiONC
APPRnVFn/IIATE
TEMP EROSION & SEDIMENT CONTROL
See general condition #2
Silt Fence as needed
Drive Off Mat to prevent sediment from leaving
the site
FOOTINGS/SLAB
Setbacks
s~ ~Q/
Forms
Reinforcement
FLOOR FRAMING (prior to skirting)
Anchors
Steel Support Piers -Load-stamped and installed
per manufacturer's installation manual,- clearance
of I S"min. from lowest point of I-beam and the
ground or footing for min. of 75% of area under
home w/ 12 "min. elsewhere unless installation
manual specifies, otherwise area around home
graded to provide runoff away from home.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
PerndI NBLDOI-053
RE UIRED INSPECTIONS APPROVED/DATE
PLUMBING:
Water Supply -Main shut-off valve (port or ball valve)
installed in water supply piping prior to connection to
"
home, min. '/,
diameter, same as supply pipe
~
Pressure Reduction Valve if> 80 psi ~ ~
Hose Bibs (backflow protection required)
Pipe Insulation -Outside & in crawl space cl r
Pressure Test -100 p.s.i. for IS minutes p r l b o \
Pressure relief valve drain - to exterior of skirting,
exhaust dowmvard between 6"and 24"above ground
Drainage Piping -sloped min. %. "per foot ~-
MECHANICAL 1
~
Ducts & Duct Insulation ' \~ ,
Dryer Exhaust -vented to outside. Extension into crawl
space requires venting through skirting with no dips;
~
~
O ~
follow dryer marmfacturer's instructions; total combined ~
/
length of ducting not to exceed 14' w/ 2-90° elbows I
b G-
FRAMING: ~
Entry Porch/Decks ~ n~ 6 ,
'0 01
VAPOR BARRIER
6 mil black poly ground cover (not required where area 1 G
~ b b ~
under home is concrete slab floor with a minimum _'
~ ' ~ ~
thickness of 3-% inches)
FINAL ~~ ~ ,
Public Works Sign-Off -, OIL '
Electrical (L & I) Sign-Off D~`~ ~ ~~ ~ ~ `
Ouse Number - muumum numbers
Plumbing a 1~ ~'b G
Mechanical ~ ti~ $ ~ o ti
Final - Buildin
No holes or gaps greater than %. "allowed in skirting.
Crawl space ventilation per installation manual @
1/150 (]8 required), located close to corners, on at least
two opposing sides for cross ventilation.
Crawl space access must provide access. to all areas
under home, minimum 18 " x 24 ", covered with vinyl, ~ l~~O f
pressure treated wood or metal.
I
Call 48 hours before you dig for. utility line locates
1-800-424-5555
Page 2 of 3
Permit ttBLD01-053
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
reeistration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construMion; ca11385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Soils exposed during construction shall be
temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with
seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of
adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
. 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department at 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
I-800-424-5555
Page 3 of 3