Loading...
HomeMy WebLinkAboutBLD01-047Waterman and Katz Building 181 Quincy Street Suite 301 Port Townsend, WA 98368 Phone (360)379-3208 Fax (360)385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLDOl-047R-2 Issued: 05/29/03 Parcel Number: 972 903 101 Job Address: 1356 54`s Street Zoning: RR=I Type: V_N Occupancy: R-3/U-1 Total Occupant Load: 2 Nature of Work: Rev #2: Finish ADU above earaee/shop. Owner: William Torell Contractor: Same as Owner GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REOUIItED: Electrical -Contact Labor & Industries @ 360-417-2'702 For other inspections, see original inspection record BLD01-0478-1 for garage/studeo/shop, and BLD01-047 for house (1354 54`" Street). RF,OTITRF,D TNSPF,CTIONS APPROVED/DATE PLUMBING Rough-In (D-V-T & Clean Outs) Water Supply Gas Supply Pipe Insulation (R-3) Pressure Reduction Valve if> 80 psi Water Heater Seismic Restraint Straps Pressure Relief Valve Drain to exterior; Elbow down, terminal 6" - 24" A.F.G. MECHANICAL LPG Stove Manufacturer's Installation Instructions to be on-site @ time of inspection Whole House Fan Bathroom Fan Kitchen Fan Environmental Air Exhaust ducting, termination and Insulation Ca1148 hours before you dig for utility line locates 1-500-424-5555 Page 1 of 3 Building Permit #BLDOI.047R-2 REQUIRED INSPECTIONS APPRnVED/DATF. FRAMING -see also original inspection record Walls Ceiling Windows -escape provided @ door Door U-Factor .20 or better Windows Ufactor - .40 or better NFRC window sticker must be on windows at inspection time Air Seal Fresh Air: wall port INSULATION Floor (R-30) Walls (R-21) Vaulted Ceiling (R-30) Baffles Vapor Barrier (paint, faced batts or 4 mil. poly) DRYWALL NAII.ING ` Walls t 03 ~l Ceiline __-_____-__ __ Verify occupancy separation R-3/U-1 FINAL -see also original permit BLDOl-047 Plumbing MechanicaUHeating Insulation Certificate Vapor Barrier Paint Certificate (if applicable) LPG Smoke Detector Stairs, Handrails, Guardrails Final -Building GENERAL CONDITIONS 1. ContraMors working on this project are required to have a Labor 8c Industries contractor's re¢istration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of way shall be kept free of dirt and debris. Soils exposed during construction shall be temporarily stabilized with mulching; plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 3 Building Pemtit kBLD01-04~R-2 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294; a minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspeMion per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. • Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3 _.~ w,ceman s x~eu:ta~ 1 el Quincy Street, Suite 301 Pat Tavmend WA96368 Phone: (360) 379-3208 Faz: (360) 3857675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION STTE Ca11385-2294 for Inspection Permit Number: BLDOI-O47R-I Issued: 4111/01 Parcel Number: 972-903-101 Job Address: 1354 54`° Street Zoning RR=1 Type: V-N Occupancy: U-1 (BLDOl-047R-1) Total Occupant Load: 6 Nature of Work: Construct Detached Garaee/Shop (see BLDOl-047 for house Owner: William Tore1l Contractor: Same as Owner GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-4I7-2702 ****AlT engneered details require inspection prior to cover**** REQUIRED INSPECTIONS APPROVED/DATE TEMP EROSION & SDM'T CONTROL See General Condition #2 Silt Fence as needed Drive Off Mat to prevent sediment from leaving the site MONOLITHIC SLAB Setbacks ~~ZO R~v~,!,.,~,~,is~r.~ ~p/ZD~D~ Footings (, Forms Reinforcement Interior Footings Anchor Bolts Engineered Holdowns LIFER Ca11 48 hours before you dig for utility line locates 1-500-424-5555 Page 1 of 4 `, ~~ a awo~.oam-p REQUIRED INSPECTIONS APPROVF.>n/f)AT F. FLOOR FRAMING NOTE: Engineered BCI joist plan shall be on-site for the /1~/ ~ // / !'' / O~ inspector at inspection time ( Joists Blocking Positive Connection Treated Wood to Concrete Anchor Bolts & Washers Shield Under Posts PLUMBING: ` ~' _ ~/~ P fa. Rough-In (D-V-T & Clean Outs) s` Water Supply ~ ~ ~ (j a ~-3' t~ Z Water Hamner Arrestor @ clothes washer Hose Bibs (backflow protection required) ipe Insu anon Pressure Reduction Valve if > 80 psi MECHANICAL Dryer Ducting with backdraft damper Utility Room Fan Environmental Air Exhaust ducting (with backdraft dampers), insulation (R-4) and terminus (located 3' from opening) FRAMING: NOTE: Engineered elements require inspection prior to cover Walls E i d Sh ll W ng neere ear a s Roof / 1~~~~y Attic Venting -gable end & eave Ceilings Posts,beams&headers-4"x l2"DF#1@garage 0.~. door per. engineering .Engineered Ridge Beam ~ l o Windows -safety glazing (if applicable) Air Seal s . Z j • Off. Rafter Positive Connection - Hl Fire Blocking Weather Resistive Barrier ,, ~, • Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 4 REQUIRED INSPECTIONS APPROVED/DATE ~, „ Prnnit#HLD01 -067R-1 DRY WALL NAILING walls (~/2, 1~~~ ~- Ceiling R-3/CT-I Occupancy Occupation FINAL LPG Public Works Sign-Off House Numbers - 5" Plumbing MechanicaVHeating Insulation Certificate Smoke Detectors Final -Building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. AI- elements of engineering including nailing, hotdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. CaII 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 _. ~ - , ~~ «B~~ aa~a.~ . 8. All building permits expire if no progress has been made within six months, or if no inspeMions are done by the Building Department within one year. Call for at least one inspeMion per year to keep your building permit active. 9. Revisions require submittal and approval arior to making changes in the field. ContaM the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates I-800-424-5555 Page 4 of 4 Waterman & ICNZBuilding In Qaiary Street, Stite 301 Pan Towrend, WA 98368 Phmw: (360) 379-3208 Fac (360) 355-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE CaII 385-2294 for Inspection Permit Number: BLDOI-047 Issued: 4/11101 Parcel Number: 972-903-101 Job Address: 1354 54t° Street Zoning RR=1 Type: V-N Occupancy: R-3/U-1 (BLDOl-047R-11 Total Occupant Load: 216 Nature of Work: Construct Sinele-family Dwelline (see BLDOl-047R-1 for ara e Owner: William Torell Contractor: Same as Owner GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REOUHiED: Electrical -Contact Labor & Industries @ 360-417-2702 ****All eneineered details require inspection prior io cover**** RF.nTTTRF,T) TNSPF.('TIONS APPROVED/DATE TEMP EROSION & SDM'T CONTROL See General Condition #2 Silt Fence as needed Drive OffMat to prevent sediment from leaving the site FOOTINGS Setbacks ~~'~ ~'N"~-ti . ~/2O/4J~ Footings J Forms Reinforcement Interior Footings Chimney Footings Porch Piers UFER L)~ ° ' ~~ Call 48 hours before you dig for utility line locates / / , / / 1-800-424-5555 Page 1 of 4 r~mastno~.oa~ REQUIRED INSPECTIONS APPROVED/DAT E FOUNDATION Stem Wall Forms Reinforcement Anchor Bolts -per engineering Vents - 9 required Crawl Access Beam Pockets Engineered holdowns FLOOR FRAMING NOTE: Engineered BCI joist plan shall be on-site for the ~// / inspector at inspection time ~ ~ O ~ yl Girders Joists Blocking Positive Connection Treated Wood to Concrete Anchor Bolts & Washers Shield Under Posts Beam Pockets Girder to Concrete Anchor Bolts & Washers PLUMBING: R h I (D T & Cl n O t V ) L P l+cst~ ~/`'~ Q ® P - n - oug - ea u s „-~, , ~ (/ Water Supply di h h W r l h ~ er ater Hammer Ar estor @ c ot es & s was ~ Gas Supply /~ rr~~ Hose Bibs (backflow protection required) ~" ,, ~(~~o `~ ' ~ 3 . ~ '~' / . .:''Pressure Reduction Vatve if> 80 psi Water Heater Seismic Restraint -strap @ 1/3 points Pressure relief valve drain to exterior; 6" - 24" above ground • Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 4 Pemtit N BLD01-047 RF.OIIIRED INSPECTIONS APPROVED/DATE MECHANICAL Fireplace -combustion air, hearth, glass doors LPG Furnace -manufacturer's installation instructions on-site at time of inspection Heating Ducts - R-8 in unconditioned space Whole House Fan -bath Environmental Air Exhaust ducting (with backdraft dampers), insulation (R-4) and terminus (located 3' from opening) FRAMING: NOTE: Engineered nailing, strapping and blacking require inspection prior to cover Walls ~ Engineered Shear Walls Roof ~~~~~~ ~~ l Attic Venting -gable end & eave Ceilings Posts, beams & headers Engineered Ridge Beam &ridge-supporting beam Windows -egress Windows -safety glazing (if applicable) Windows Ufactor - .65 or better 1 ~{ 1/ (~ NFRC window sticker must be on ~T windows & doors at inspection time ~ -y ~~ z3" Air Seal Fresh Air Intake (wall) Door UFactor - .40 or better ~ b Rafter Positive Connection - HI p Fire Blocking Weather Resistive Barrier INSULATION ~~ Floor (R-19) 8 U ®~O Wall(R-19) ' Ceiling (R-30 ) Baflles Vapor Barrier: faced Batts Crawl Space - 6 mil black poly DRY WALL NAILING Walls C'`¢=-~1~9r~3 Ceiling Ca1148 hours before you dig for utility line locates I-800-424-5555 Page 3 of 4 ?p rn,~axa~nm-pay 'l' LPG Public Works Sign-Off House Numbers - 5" Plumbing MechanicaVHeating Insulation Certificate Smoke Detectors Final -Building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294, press 3. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294, press 3. A minimum of twenty-four hours notice is required. Public Works auuroval must be received prior to schedulin¢ the Buildine Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval prior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4