CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
CaI1385-2294 for Inspection
W emrman & Katz Bwlding
181 Quinry Svee4 Sui[e 301
Pori TowosrnQ WA 98368
Phone: (360)379-3208 Fax: (360)385-7675
CITY OF PORT TOWNSEND
Permit Number: BLDOl-044 Issued: 04/16/01 Parcel Number: 957303102
Job Address: 1807 Washineton Street Zoning: RR=II Type: VV=N
Occupancy: RR=3 Nature of Work: SFR Interior Remodel: see attached scone of work.
Owner: Steahen and Deborah Lewis
Contractor: Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RFf1iTiRF.II iN~PF,C'TiONS
APPROVED/DATE
PLUMING
Yough-In (D-V-T & Clean Outs)
Water Supply
Pipe Insulation (R-3)
Pressure Reduction Valve if pressure > 80 psi
MECHANICAL
Source Specific Fans (if applicable)
Environmental Air Exhaust ducting (with backdraft
dampers), insulation (R-4), and terminus (located 3' from
openings into building)
FRAMING
Walls
Ceiling
Windows -escape
Window U-factor..40 or better ~/L l . ~ , ,
NFRC label shall be on windows and doors at time of
inspection
Window Safety Glazing
Air Seal
Fire Blocking
Deck -see attached preservative information
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
PermitMBLD01-044 ~
RE UIRED INSPECTIONS APPROVED/DATE
DRYWALL/NAILING (as applicable)
Walls
Ceilings
INSULATION.
Fill exposed cavities
Vapor Barrier Req'd: 4 mil poly, vapor barrier paint, etc.
FINAL
House Numbers -check for 5" numbers
Final -Plumbing
Final -Mechanical
Final -Deck
Insulation Certificate (if applicable)
Vapor Barrier Paint Certificate (if applicable)
Smoke Detectors in existing construction per '97 UBC
Final -Building
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license: Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspeMion report corrections sre completed.
6. The Building Department is unable to pass final inspeMion on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
J
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Pertnil #BLD01-004
7. Final Inspections are required prior to occupancy; a Certificate of Occupancy is required fora non-
residential project.
~8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
I-800-424-5555