HomeMy WebLinkAboutBLD01-043• Wekrmen&K&z Building
181 Qtinry Stree4 Style 301
Port Townsend WA 98368
Phone: (360) 379-3208 Fax: (360) 385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO1-O43 Issued: 03(05/01 Parcel Number: 957303102
Job Address: 1807 Washington Street Zoning: RR=II Type: VV=N Occupancy: R_3
Nature of Work: Remove existing roofing. realace sheeting, install comuosition and torchdown roofing
material, provide ventilation
Owner: Stephen and Deborah Lewis
Contractor: All About Building
385-2139
GENERAL CONDTI'IONS APPLY -SEE LAST PAGE
RF.Oi1iRED INSPECTIONS
,~
APPROVED/DATE
DEMOLITION
All construction debris to be deposited in Jefferson
County Landfill or other location in accordance with
all local, state and federal laws.
SHEATHING
Structural roof sheathing requires 8d @ 6" o.c. edges
& 12" field or 1'/<" staples @ 6" o.c. edges and field.
ROOF VENTING
Ridge
Net free ventilation area shall not be less than 1 square
foot per 150 square feet of the azea of the space
ventilated, unless 50% of the required vent opening
area is provided in the upper portion of the roof and
therefore the rate maybe reduced to 1 square foot of
venting to 300 square feet of azea vented. Openings
shall be covered with corrosion resistant'/<" mesh.
ROOFING
Install all roofing material per manufacturer's
specifications and UBC Chapter 15.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
:-,
FINAL
House Numbers - 5" numbers of contrasting color
posted neaz main entrance of house and visible from
street per City Ordinance
Final -Building
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering .including nailing, holdowns, sheathing, and alternate braced wsB panels
(ABWP) require inspeMion prior 4o cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
Final Inspections are required prior to occupancy; s Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within sia months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building perryit sc6ve.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2